Showing results: 3286 - 3300 of 5270 items found.
-
Edmund Optics Inc.
Detectors are used to measure the illumination of a light source for a number of optical or spectrometry applications. Detectors consist of arrays of photodiodes or photodetectors that transmit electrical current when excited by collision from photons. Detectors enable the measurement of important light characteristics that are not conveniently acquired in other ways. A selection of photodiodes is also available with linked amplifier capabilities for easier, more precise measurement capacities.Detectors
-
DMT 2004 -
Monacor International GmbH & Co. KG
*2000 digit resolution*Voltage measurement up to DC/˜ 250 V*Current measurement up to DC/˜ 10 A*Resistance measurement up to 2 MΩ*Battery test for 9V block and 1.5V cells*Acoustic continuity test*diode test*Data hold (measured value memory)*LC display with switchable background lighting*overload protection*Supplied with test leads
-
STHVP/STHVE -
HK Film Capacitor Ltd
High Voltage Pulse Current for medium frequency applicationHigh Voltage DC / AC Voltage applicationCapacitor can be discharged at rated voltage directly without any protective component and with ambient Temperature up to +105CHigh Voltage Decoupling and SnubberingVoltage MultiplierInduction heatingAct as discharge capacitor to trigger laser, X-Ray and Tesla CoilFor high voltage capacitor bank or arrayHigh Voltage Power Supplies
-
Model PZD2000A -
TREK, INC.
The Trek Model PZD2000A is a wide bandwidth high-voltage power amplifier used for precision high power applications. This new addition to the Trek power amplifier product line is designed to provide precise control of output voltages in the range of 0 to ±2 kV DC. Features include an output current range of 0 to ±400 mA and an excellent large signal bandwidth capability.
-
MS3112 -
Metal Samples Company
The Hydrogen Penetration Monitoring System™ provides a method for directly measuring the rate of hydrogen migration through a vessel or pipe wall. This method actually measures the penetration current set up by the hydrogen as it moves through the steel. By sensing and recording this data directly from the pipe wall, this system offers valuable data which can only be indirectly inferred by other methods.
-
Bee Instruments
Inductive Proximity Switches, self contained, depend on the output of an oscillator for their operation. The oscillator resonant circuit uses an open core coil to produce a concentrated high frequency electromagnetic (RF) field, which emerges from the active surface of the sensor. If a metal target (or other electrically conductive material) enters this field, eddy currents will be induced in it, causing the resonating oscillator to be damped.
-
HH2107 -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.5%). Jumbo LCD display 2000 count, 21.8mm figure height. Manual Ranging at your choice (30 Range). High Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 20MΩ. Diode test, audible continuity check and transistor test
-
HH2108 -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.8%). Jumbo LCD display 2000 count, 26mm figure height. Manual Ranging at your choice (30 Range). High Voltage test up to AC 500V and DC 500V. Higher Current test up to 20A AC/DC. Resistance test up to 20MΩ. Erequency test range from 10Hz to 1999Hz
-
8012H -
Sealevel Systems, Inc.
Optimized for sensing 24V inputs, the 8012H Low Profile PCI digital interface provides eight Reed relay outputs (SPST) and eight optically isolated inputs supporting 10-30V. Reed relays are well suited for low current applications. The relays are normally open, and close when energized. The board is MD1 Low Profile and Universal Bus (3.3V and 5V) compatible.
-
Spectrolab Inc.
InGaAs PiN sensors and sensor arraysTelcordia qualified InGaAs P-I-N photodetector device dies for the telecommunication, laser power monitoring, test systemsActive area sizes from 25 μm to 1 mm.Device die characteristics with low dark current, low capacitance and high quantum efficiencyWafer capability: 2", 3" and 4" on InP substratesHigh volume and low cost production
-
SY037 -
Synectic Electronics
The SY037 passive pulse splitter is ideal for converting pulses from meters or other turbine devices and transmitting the same pulse to three outputs to enable three separate instruments to measure the rate simultaneously. It needs no power supply. It functions simply from the pulses of the meter driving it. It is convenient for meters and any pulse generating device with reed switches, open collector or current source.
-
8003 -
Sealevel Systems, Inc.
The 8003 PCI digital I/O interface provides 16 Reed relay outputs provide high quality, long-life, low current (10 Watt maximum), dry contact switch closures. Reed relays are well suited for low-current applications. The relays are normally open, and close when energized. Writing a 1 to the proper port bit can individually energize each relay.
-
APCIE-3021-16-3 -
TEAM SOLUTIONS, INC.
The PCI-Express analog input/output board APCIe-3121 has 16 SE/differential inputs, 8 analog outputs, 16-bit, and 8 digital I/O, 24 V. The board is especially suited for applications in industrial process control, measurement technology and monitoring, for example for multichannel data acquisition, for the control of chemical processes, for the acquisition of sensor data, current measurement etc. in the harsh industrial environment.
-
Altium Inc.
The PDN Analyzer powered by CST allows you to easily resolve PDN issues as they arise in your board layout process without ever relying on a physical prototype. With digital designs continuing to increase in density and complexity, it's more difficult and critical than ever to fully understand the impact of design decisions on your Power Distribution Network (PDN) voltage and current performance.
-
I 520 -
LMT Lichtmesstechnik GmbH
display range 0.01 nA (last digit) to 7 999 μA4-digit display (0-7999) with dimmer for brightness controlV.24-(RS 232-) Interface, analog outputranging auto/manual or remote programmableapprox. 2.5 readings/s, attenuator 100% to 0dark current compensationpower supply for thermostatic stabilized LMT photometer headspower supply 230 V, 50-60 Hz, power cable with Euro plug