Showing results: 3481 - 3495 of 5270 items found.
-
MTI Corp.
Real-time welding current monitoringAutomatic alarm system to avoid poor quality weldingArbitrary point restarting after the welding adjustmentThe welding time is less than 1 second and the discharging time for the battery cell is about 1 ms.Welding programmable; It is able to skip welding one or more battery cells by programmingFan cooling the welding needleTwo sides welding at the same timePLC controlEmergency stop and alarm system
-
ViTec Co. Ltd
The number of the current hopper and the correct positioning, along with the indication of power and status, are displayed on the indicators. Four load cells are mounted on the cart. The system records the amount of material shipped from each hopper, and the total weight of the material in the trolley is also displayed. All information is stored in the controller memory for a specified time. After the necessary time intervals, the operator can rewrite the information on the USB drive for further processing.
-
DIT-5200L -
Kaman Fuzing & Precision Products
* True differential for common mode rejection at an economical price* High precision eddy current balanced bridge technology* Capable of subnanometer resolution* Thermal stability ±.03% FS/°C, at null ±.005% FS/°C* Small package size: just 7.7 cubic inches* High sensitivity: up to 10V/mil (39mV/μm)* Extremely linear, to 0.1% full range* Single and dual channel configurations
-
MBT series -
Maury Microwave Corporation
The MBT-series of bias tees is based on Maury's patented broadband capacitor (US Patent 9,614,267) which simultaneously enables the industry's widest bandwidth, lowest insertion loss and lowest return loss in a coaxial bias tee up to 18 GHz. In addition, its unique design makes it ideal for pulsed applications, including pulsed IV and pulsed load pull characterization, without distorting the voltage and current waveforms.
-
18534PS1 -
Carl E. Holmes Company
Input power is 380 VAC, 3 PH, 50 Hz, P/N 18534PS1Output is 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDCIndoor enclosure, 50"H x 46"W x 36"DOutput voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure
-
e–FlashFS -
Bruker Nano Surfaces
The new EBSD detector e–FlashFS has been designed for maximum sensitivity to allow highspeed EBSD measurements without compromising data quality – even on challenging applications like deformed or lightweight materials. To further improve the pattern quality, the cooling system of the e–FlashFS has been upgraded to lower its functioning temperature and therefore reduce the dark current of the CCD camera as much as possible.
-
Osborne Transformer Corp.
Osborne designs harmonic trap inductors to work in conjunction with capacitors in power systems to prevent specific line-frequency harmonics from flowing back to the power source (point of common connection). This power quality design approach prevents harmonic currents from flowing to the main facility power system and/or to the utility power system. The Osborne system also reduces unnecessary power losses and power-system pollution.
-
260 Series -
SCI
Our 260 Series makes Ground Bond testing simple. We offer two models so that you can have a simple and easy-to-use Ground Bond tester that provides the output current you need to satisfy NRTL specifications. With an intuitive interface that allows you to set-up a test in seconds and practical security settings, our 260 Series can easily be deployed in both laboratory and production line environments.
-
B2980A Series -
Keysight Technologies
Both the picoammeters and electrometers provide a world-best performance of 0.01 fA (0.01 x 10-15 A) current measurement resolution. In addition, the electrometers can measure resistance up to 10 P (10 x 1015 ), which is also a best-in-class specification. Finally, since AC power line noise can be difficult to eliminate when making low-level measurements, both the picoammeters and electrometers are available in battery powered versions.
-
CRY5620 -
CRYSOUND
CRY5620 Microphone Tester can test many types of microphones, such as electret and MEMS. This instrument adopts SCM control and combines digital-analog processing technology, signal set generation, signal processing and data display. It can display the sensitivity of a microphone at low, medium and high frequencies, as well as the microphone current. Featured by easy-to-operation, user-friendly setup interface, fast and accurate testing, it is ideal for production lines and metrological service organizations.
-
cPCIS-2633 Series -
ADLINK Technology Inc.
*3U CompactPCI® backplane with 12 peripheral cand slots and one system slot*2 + 1 hot swappable 500 W + 250 W CompactPCI® Power supply (supports three 250 W PSUs)*Temperature, voltage, and fan monitoring LEDs*Supports current sharing on +5V, +3.3V, and +12V*PICMG® 2.11 47-pin power interfaceHot-swappable cooling fans & filter
-
MS 1118 -
Meltronics Systemtech
Test Set-A calibration unit is a test jig is used to simulate parameters of Adour 804E and 811 engines of Jaguar aircrafts. It simulates current, voltage, speed, and turbine gas temperature. It performs NL Check, NH Check, TGT1 (Non T2 Compensated), TGT2 (T2 Compensated), Amp (Non T2 Compensated), Amp (T2 Compensated), Solenoid Volt, TGT Inject, NL Inject, and NL/TGT Redatum.
-
61500 Series -
Chroma Systems Solutions, Inc.
Power:500VA (61501)1500VA (61503)2000VA (61504)4000VA (61505)Voltage range: 0-150V/0-300V/AutoCompact size and weight attributable to advance PWM technologyAC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyLow output impedance for testing IEC 61000-3-2 (61505)Programmable output impedance for testing IEC 61000-3-3LIST, PULSE, STEP mode function for testing power line disturbance (PLD) simulation capabilityIEC 61000-4-11 voltage dips, short and variation simulationHarmonics, inter-harmonics waveform synthesizer for testing IEC 61000-4-13Programmable voltage, current limitComprehensive measurement capability, including current harmonicsHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientAnalog programmable interface3 units combined to 3-phase power outputEasy-use software for operation and IEC regulation testOptional GPIB and RS-232C interface
-
61600 Series -
Chroma Systems Solutions, Inc.
Power:500VA (61601)1000VA (61602)1500VA (61603)2000VA (61604)4000VA (61605)Voltage range: 0-150V/0-300V/AutoFrequency: 15Hz 1000HzCompact size and weight attributable to advance PWM technologyBuilt-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage, current limitOne-key recall for 9 different voltage and frequencyLow output impedance for testing IEC 61000-3-2 ( 61605 )Comprehensive measurement capability, V, Irms, Ipk, Inrush, P, Q, S, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates ON/OFFAnalog programming interface3 units combined to 3-phase power outputEasy-use software for operation and ON/OFF testOptional GPIB and RS-232C interfaceFull protection: OP,OC,OV and OT protection
-
SY8125 -
Hong Kong Songyang Industrial Ltd.
The devices are fully made by aluminum alloy materials and the table board is composed of fireproofing and heat-proof materials. ● The output voltage and current use soft startup and stop. It has the protection functions of voltage short circuit, current open circuit and power amplification exception.● The device has the features of high stability, good reliability and large output power. ● High level of autoimmunization. The coexistence of special small keyboard and PCs, convenience to use.