Filter Results By:

Products

Applications

Manufacturers

Showing results: 5116 - 5130 of 5232 items found.

  • 12V 0-500 Amp Carbon Pile Battery Load Tester and 12/24V Electrical Systems Tester

    6042 - Associated Equipment Corp.

    • Test batteries up to 1000 CCA• Interprets data from the charging/starting system on easy-to-read LCD displays• Shows positive and negative amps for easy diagnosis of current leakage problems• 0-500 Amp variable carbon pile load tester• Unique curved carbon discs ensure maximum contact, fewer hot spots, smoother operation and longer life• Heavy-duty single extruded leads for testing up to 15 feet apart• Test electrical systems on 12/24 Volt systems• Test all battery types• Ideal for testing remotely mounted batteries accurately• INCLUDES: Model 6043 1000 Amp AC/DC Inductive Amp Clamp for checking starter draw or parasitic drain test, also can be used with conventional multi-meters; heavy duty, two wheel tilt-back cart with 8” wheels and 2 trays.• Made in USA of US and Global Components

  • Fibre Channel PXI Express Test & Simulation Instrument

    PXIe-FC4 - Avionics Interface Technologies

    3U PXIe form factor will fit into any PXIe or hybrid slot - Supports Point-to-Point, Switched Fabric, and Arbitrated Loop topologies - Two independent Fibre Channel ports - Two SFP sockets accept fiber or copper transceivers - Each port supports 1, 2, and 4 Gbps speeds - Comprehensive decoding of FC-1, FC-2, and Upper Layer Protocol (ULP) frames - Triggering and Filtering - Error Injection on any Header or Payload Parameter - Data Capture to on-board memory or disk file - Live Capture and Current Value Monitoring - IRIG-B Time Code Encoder/Decoder for Data Correlation - In-line Port Configuration for Transparent Analyzer - Supports multiple ULPs including FC-AE-ASM, FC-AE-RDMA, FC-AE-1553, and FC-AV - Supports HS-1760E applications, including AS5653, AS5625, and AS5627fcXplorer Windows-based FC Simulator and Analyzer Test Software

  • Array Antennas

    ERAVANT

    An antenna array (or array antenna) is a set of multiple connected antennas which work together as a single antenna, to transmit or receive radio waves. The individual antennas (called elements) are usually connected to a single receiver or transmitter by feedlines that feed the power to the elements in a specific phase relationship. The radio waves radiated by each individual antenna combine and superpose, adding together (interfering constructively) to enhance the power radiated in desired directions, and cancelling (interfering destructively) to reduce the power radiated in other directions. Similarly, when used for receiving, the separate radio frequency currents from the individual antennas combine in the receiver with the correct phase relationship to enhance signals received from the desired directions and cancel signals from undesired directions. More sophisticated array antennas may have multiple transmitter or receiver modules, each connected to a separate antenna element or group of elements.

  • Cryogenic Applications

    Celadon

    Over the last 20 years the Celadon Engineering team has developed an expertise in cryogenic materials which has resulted in a solid reputation in the industry for producing extremely stable cryogenic on-wafer probe card as well as DUT probing solutions. These custom cryogenic probe card solutions are widely used to test Space, Military, Medical and Quantum Computing products. Celadon’s cryogenic solutions vary from standard VersaTile™ footprints which interface to positioners to innovative custom PCB based designs to allow for flexibility when testing at these very cold temperatures. Lakeshore cryogenic wire is used in standard DC solutions for high density cableout designs to support high pin count applications. During the development process, Celadon works closely with the cryogenic prober vendor to ensure the integrated solution is optimized for current and future testing needs.

  • Cryogenic 4K Probe Cards

    Celadon

    Over the last 20 years the Celadon Engineering team has developed an expertise in cryogenic materials which has resulted in a solid reputation in the industry for producing extremely stable cryogenic on-wafer probe cards as well as DUT probing solutions. These Cryogenic probe cards have all the benefits of Celadon’s Crash Resistant™ probe technology but with the ability to probe as cold as humanly possible. Celadon’s cryogenic solutions vary from standard VersaTile™ footprints which interface to positioners to innovate custom PCB based designs to allow for flexibility when testing at these very cold temperatures. Lakeshore cryogenic wire is used in standard DC solutions for high density cable-out designs to support high pin count applications. During the development process, Celadon works closely with the cryogenic prober vendor to ensure the integrated solution is optimized for current and future testing needs.

  • Transformer Turns Ratio Meter

    TTRM 102 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types.  TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.

  • Battery Loading Unit

    BLUe - Scope T&M Pvt, Ltd.

    BLUe series Battery Loading Units; portable instruments for controlled & monitored discharge of batteries. It is designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Single autonomous unit having inbuilt display, keypad and wireless communication with PC makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents. Various options are available to control & monitor the discharge process. With the help of optional Cell Monitoring Unit - CELLMon, voltage of each individual cell can be monitored & data sent to main BLUe unit and then from main unit to PC via wireless communication. Each BLUe unit is supplied with PC downloading & analysis software for real time monitoring of discharge process.

  • Reflection Meter

    RC-088 - Rinch Industrial Co.,Limited

    This instrument is a special equipment for measuring the reflectivity of rearview mirror (or similar product) of motor vehicle. The product composes intelligent measuring instruments, optical integrating sphere, parallel lamp, standard light source, constant current source etc. It is easy to operate,it can measure the reflectivity quickly and accurately. On instrument structure, it adopts standardized modulation design. It takes latest single chip as its digital central processing element. After the measuring signal is converted by modulus, CPU will do some computation and compensation. The instrument can display the reflectivity of device which is measured in rear time. It operates simply and quickly, the indication is direct and accurate. It’s good for quality examination &control in the production scene as well as laboratories. This product has the convenience &quick demarcation way, can meet requirement of different occasion. It is applicable for measuring light reflection on mirror and not mirror parts.

  • High-Dynamics PIMag Linear Stage

    V-522 • V-524 • V-528 - Physik Instrumente GmbH & Co. KG

    Reference-class linear stage. Linear positioning stages with magnetic direct drives largely dispense with mechanical components in the drivetrain and the drive force acts directly on the motion platform. Together with precision bearings, a high travel accuracy and longer lifetime is achieved. The linear positioning stages are particularly suitable for scanning applications. PIMag® Voice Coil. Voice coil drives consist of 2 essential components: A permanent magnet and a coil, which is located in the air gap of the magnetic field. When current flows through the coil, it moves in the magnetic field of the permanent magnet. The direction of motion depends on the polarity. Thanks to their low weight and friction-free drive principle, voice coil drives are particularly suitable for applications, which require high dynamics and high velocities at limited travel ranges. High scan frequencies and precision positioning are also possible with these drives, because they are free of the effects of hysteresis.

  • Energy Saving System

    ECO-Vibe neo - EMIC Corporation

    ECO-Vibe neo has been designed for an eco-friendly vibration test system. The test conditions with a vibration test system depends on a unit under test. Generally, the exciting force required for performing a vibration test can be calculated by the product of mass (e.g. test article, jig, table, etc.) and test acceleration. But, when the required exciting force is smaller than the maximum rated exciting force of the vibration test system, the field power supply that the constant current has to be continuously provided to produce the DC magnetic field constitutes a large part of power consumption compared with the drive power for the moving element. ECO-Vibe neo can reduce the power consumption by choosing the exciting force in this case. In addition, you can enjoy a reduction merit of the running cost from the first year when the system is introduced because initial cost is zero.

  • Measurement System for ESD Protection

    SampleProtect - Oxford Instruments plc

    The SampleProtect measurement system is ready to go, and comes complete with Oxford Instruments’ Cryofree bottom loading cryostat – the OptistatDry BLV, Zurich Instruments’ MFLI Lock-in Amplifier, a specially designed ESD break-out box and high quality measurement grade cables. The patent-pending puck style mounting from Oxford Instruments provides safe installation of your samples. The MFLI 500 kHz Lock-in Amplifier (capable of 500 kHz demodulation as standard) with MF-MD multi-demodulator capability brings the benefits of high performance signal processing at low and medium frequencies. The differential voltage and current inputs of the MFLI are optimised for low noise operation and the high oversampling rate ensures an even better signal to noise ratio. Zurich Instruments’ unique LabOne® control software provides a toolset including an integrated oscilloscope, a spectrum analyser, a plotter and a parameter sweeper.

  • New Link system Control and Image Capture Software

    Linkam Scientific Instruments

    New uncluttered and intuitive user interfaceLive display of current status for easy monitoringFull control of heating and cooling rate, limit and hold time of up to 100 rampsRow by Row control of Vacuum, Humidity, Tensile Force and Shear modes controllable and synchronised with TemperatureParameters of connected Linkam sensors displayed and stored - e.g. Vacuum, Humidity, Force, XY position and Pressure (dependent on connected stage type)Real Time chart of temperature and other measured parametersTrigger I/O for synchronisation with other equipmentTriggers recorded and plotted row by rowAutomatic setup of controls and parameter limits based on stage type connectedFull five point temperature calibrationUSB 2.0 to T96 and CSS450 ControllersOptional modules including Linkam Imaging Systems with high performance camerasIncludes .NET Components for easy integration into 3rd party applications e.g. LabViewNative 64 bit application

  • Near-Field Probes 100 kHz up to 50 MHz

    LF1 set - Langer EMV-Technik GmbH

    The LF1 near-field probe set consists of 4 shielded near-field probes used during the development process for emission measurement of longwave, medium wave, and shortwave frequencies on electronic devices. The probe heads of the LF1 set are designed for incremental detection of sources of electromagnetic interference on assemblies. First, the electromagnetic interference of the assembly is detected by the LF-R 400 probe from up to 10 cm. Then probes with higher resolution like the LF-B 3, LF-U 5 and LF-U 2.5 are used to more precisely detect any source of interference. The probe heads are designed for taking measurements at single pins and larger components. Near-field probes are small and handy. They have a current attenuating sheath and, therefore, are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. The H-field probes do not have an internal terminating resistance of 50 Ω.

  • 12 Function True RMS Professional MultiMeter + InfraRed Thermometer

    Extech EX470A - Extech Instruments Corporation

    The Extech EX470A True RMS Multimeter and Infrared Thermometer with Capacitance, Frequency, and Duty Cycle Measurements and 2 K-Type Remote Probes is the perfect meter for HVAC or plant maintenance. The IR thermometer measures the surface temperature from -4 to 518 °F (-20 to 270 °C) without contact. The built-in laser pointer centers the measuring area. Multimeter functions include AC and DC Voltage to 600 Volt, AC and DC current to 10A, resistance to 40MOhm, continuity and diode test. Also includes Type K thermometer for contact or air temperature measurements from -4 to 1832 °F (-20 to 750 °C). Advanced functions include Capacitance, Frequency and Duty Cycle. The meter comes complete with test leads, Type K temperature probe, 9 Volt battery, protective holster, adjustable tilt stand and Velcro hanging strap.

  • Manual Oscillators

    MOS-01, -01A - Compact Power Company

    The MOS-01 manual oscillator module is used as a quality, general-purpose sinewave oscillator and digital readout monitoring system in the MAC-01, -02, or -03 AC Power Sources/Frequency Converters. The unit has guaranteed operating range of 20 HZ to 20 KHZ which is covered in three one-decade scales. The LCD digital metering system is switch-selectable to readout either frequency, voltage or current. A toggle switch selects the input for the attached AC Power Source/Frequency Converter to originate from the manual oscillator itself or from an external laboratory or programmable oscillator source. With oscillator mode switch in Internal position, the BNC connector delivers the signal to drive additional slave units or for oscilloscope sync or monitoring. BNC input/output is completely isolated with 1500 VAC breakdown and excellent common mode rejection. The oscillator modules must be factory installed and calibrated.

Get Help