Electrical Testing Solutions
Short-Circuit Currents are currents that introduce large amounts of destructive energy in the forms of heat and magnetic force into a power system.
-
P50 -
Beijing GFUVE Electronics Co.,Ltd.
mv AC clamp on current probe has 1mV voltage or 1mA current output, can measure cable and bus bar, max current is 1000A, high precision, can be used to monitor power quality. Perfect material permalloy core.
-
ET System Electronic GmbH
*Fast regulation of the current*Voltage depends on the load*Current and voltage values are configured based on the customer's actual requirements*Power from 250VA to 36kVA*Output voltages 1VAC to 300VAC*Maximum currents up to 2000A per phase
-
Cambridge Instruments & Engineering Co.
A clamp meter is a clothespin-shaped instrument that can be clamped around a live wire in order to measure the current it's carrying. As a measurement principle, clamp meters detect the magnetic field emitted by current flowing in a wire in order to measure the current value.
-
HA-GFD -
Summit Technology, Inc.
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
3920 CL -
Standard Electric Works Co., Ltd
● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Low battery indication.
-
ETAP Enterprise
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
Megger Group Ltd.
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
5658 -
Abaco Systems Inc
ECM P/N 5658 provides eight channels of 16 bit current measurement in the 0 to 25 milli-amp range. Each channel allows independent common mode voltages from -100 volts to +100 volts. Current detection is accomplished with a precision 100 ohm current sense resistor, creating a voltage drop of 2V in the current loop at 20 milli-amps.
-
Beha-Amprobe
Is an electrical test tool that combines a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage.
-
Brymen Technology Corporation
An electrical test tool that combines a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage.
-
SERIES 93 -
Test Connections Inc.
ElectricalMAXIMUM CURRENT: 7 amps continuousat working travel, non-inductiveRESISTANCE: At 35 mA test current,35 mOHMS mean
-
-
M-310 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*The unique U type CT enabled to measure the load current of single or three phase cable without separating the cable to the wires.*Leakage current measurements with least affection from the external magnetic field.*Wide current measurements.(AC0.01mA-300A)
-
LXinstruments GmbH
Leakage current and discharge current depend on the insulation of the device. The measurement simulates various fault situations that could occur during operation. The test determines whether the measured current is within the permissible limits and poses no danger to the user in case of a fault.