Filter Results By:

Products

Applications

Manufacturers

Gas

1) fills any space it's contained in and is amorphous. 2) liquid fuel powering vehicles.

See Also: Dissolved Gas, Gasoline, Ammonia


Showing results: 496 - 510 of 1390 items found.

  • MPS™ Refrigerant Gas Sensor

    NevadaNanotech Systems, Inc.

    NevadaNano’s Molecular Property Spectrometer™ (MPS™) MPS Refrigerant Gas Sensor provide accurate and reliable detection of mildly flammable (A2L) R-32, R-454b blends, R-1234yf and other low global warming refrigerant gases such as  (A1) R744 as well as (A3) R290 and R600 common in HVAC applications. With a 15+ year calibration interval and lifetime, the MPS A2L Refrigerant Sensors deliver industry-leading performance and the lowest total cost of ownership.

  • Low Power Wireless Gas Detector

    CX - Teledyne Gas & Flame Detection

    Model CX sensors are equipped with standard analog 4-20mA, and Modbus™ RTU RS-485 outputs and can be used with SmartWireless Site Sentinel CX/CXT controllers. The CX is a very low power device making it an ideal choice for a battery powered detector (optional) in applications where power is unavailable or not economically feasible.CX gas detection sensors are easily and economically deployable in both permanent and temporary installations. These low power sensor assemblies utilize electrochemical technology for a long list of toxic gases.​​​​​​​​​​​​​​​​​​​​

  • Fire, Gas & Intruder Controllers & Alarms

    MultiSafe-MX - Teledyne Gas & Flame Detection

    The MultiSafe-MX system is intended for the protection of high hazard, high risk plant and facilities.The MultiSafe-MX is certified, by European laboratories, to comply with the applicable regulations.The panel is composed of dedicated cards, installed in 19” racks which have their own “intelligence”, programmed for active/passive fire protection, gas detection, intruder alarm and logic functions. Moreover, the MultiSafe-MX can interact with supervisory and SCADA systems via Ethernet, TCP/IP or Modbus.The MultiSafe-MX interfaces with devices using either conventional and/or addressable module inputs and outputs. These modules are used to tailor the system to customer requirements.

  • Gas Detector — Methane, Butane, Propane

    ENVIROMUX-GD-MBP - Network Technologies Inc

    Use to detect leaks of combustible gas (methane, propane, butane, acetylene, etc.). Choose between two levels of detection. First level: Detects methane at concentrations in excess of 0.5%; Detects propane/iso-butane at concentrations in excess of 0.3%. Second level: Detects methane at concentrations in excess of 0.8%; Detects propane/iso-butane at concentrations in excess of 0.5%. Continuous air monitoring. Audible alarm signal: 94 dB at 1 foot. Relay specifications: level selectable, normally open or normally closed, 250V AC, max 5A. Maximum cable length: 1000 ft (305m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: CE.

  • Open Path Combustible Gas Detector

    SafEye (Quasar 900) - Teledyne Gas & Flame Detection

    The Open Path Combustible system detects hydrocarbon gases by analyzing the absorption of radiation caused by gases in the atmosphere and comparing it to background atmospheric absorption. This is accomplished between a pair of units: a Flash Source and a Detector that can monitor a distance of up to 200 meters.Open Path Combustible Gas Detectors are robustly designed and can handle the toughest environments: 316L stainless steel housings that meet IP66/IP68 and NEMA 250 6P egress standards; circuit boards epoxy coated for protection; MIL-C-810C testing for humidity, salt, fog, vibration, mechanical shock and temperature extremes; and SIL-2 approval per IEC61508 is a final statement in reliability.

  • Ar Gas Cluster Ion Source

    GCIS - Kratos Analytical Ltd

    The Kratos Ar Gas Cluster Ion Source (GCIS) is optimised for depth profiling organic materials in Arn+ cluster mode and inorganic materials in Ar+ monomer mode, dependent on the operating parameters defined by the user and the type of material to be profiled. In Arn+ ion cluster mode the ions can be accelerated up to a maximum of 20 keV. This enables the successful sputter depth profiling of the widest range of polymer materials to be undertaken. However, Arn+ cluster depth profiling has been shown to give very low sputter yields for inorganic materials. In order to retain the capability of generating depth profiles from this class of materials this ion source can also be operated in the more conventional Ar monomer (Ar+) mode.

  • Gas Filter Correlation CO Analyzer

    Model T300U - Teledyne Advanced Pollution Instrumentation

    The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.

  • Gas Filled Hv Test Transformer

    YDQW-50KVA/250KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • Gas Chromatograph for Analyzing Pure Argon

    GC2010R - Chongqing Kailian Yongrun Industrial Co.,Ltd.

    GC2010R pure argon analyzer performs trace analysis on H2, O2, N2, total carbon (CH4, CO, CO2) in pure argon. It is equiped with FID, TCD, methane converter, ten-way injection valve, special chromatographic column. The whole analysis is completed through one injection with ten-way injection valve.

  • Gas Chromatograph for Analyzing Trace Hydrocarbon

    GC2010B - Chongqing Kailian Yongrun Industrial Co.,Ltd.

    To analyze trace hydrocarbon (C1 – C4) in liquid oxygen, liquid air, air at exhaust inlet of air separation equipment, and trace hydrocarbon (C1 – C4) in liquid oxygen tank. Provide data for safety production of oxygen generator and guide the production.

  • Highest Precision Pure Gas Analyzer

    iso DUAL INLET - Elementar Analysensysteme GmbH

    Dual inlet technology is the most precise, accurate and sensitive technique for carbonate and water analysis. Because of this, the iso DUAL INLET has a unique role in the paleoclimate applications where instrumental precision contributes directly to the precision of paleoclimate models. Whilst the world's climate continues to behave erratically, we must know what has happened in Earth's history before we can attempt to predict what will happen in the future. To elucidate this complicated story, the iso DUAL INLET is a valuable tool for paleoclimatologists to build a detailed picture of the past to better inform policy makers who might just be able to influence the future of our planet.

  • Handheld SF6 Gas Leak Detector

    XP-1A / 696 - Wuhan Huatian Electric Power Automation Co., Ltd.

    We have more than 30 years of production experience, recently launched a new generation of automatic intelligent leak detector.

  • 8-Gas On-Line Transformer Gas Analyser

    TRANSFIX - GE Digital Energy

    The TRANSFIX is an 8-gas on-line transformer DGA monitoring unit. Using specially developed advanced photo-acoustic detection technology, the TRANSFIX measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect and diagnose a complete range of transformer faults.

  • Analyzer for Total Sulfur in Gas Application

    SGA-1000 - Atom Instrument

    The ATOM SGA-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.ATOM Instrument offers the most versatile total sulfur analyzers available. The ATOM SGA-1000 has the fastest analysis time of any commercially available analyzer allowing user-defined, multiple cycle averaging to improve analyzer performance. The analyzer operating software is both intuitive and user-friendly. In addition, the ATOM SGA -1000 only requires bottled air for normal operation and does not require installation in a shelter.

  • Inverse Gas Chromatography-Surface Energy Analzyer

    (iGC-SEA) - Surface Measurement Systems

    The iGC-SEA is a second generation iGC instrument. It is the world’s only commercial instrument based on the iGC principle. The unique SMS injection scheme provides a wide range of injection concentrations with unrivalled accuracy and reproducibility.

Get Help