Showing results: 961 - 975 of 1357 items found.
-
SEMOZON® AX8407 -
MKS Instruments
The SEMOZON AX8407 generator converts pure oxygen into ozone through silent electrical discharge and achieves high output and high concentration level. It requires only minute levels of dopant nitrogen gas, far below the levels required for competitive ozone generators. As a result, the presence of contaminants, e.g. NOx compounds, is extremely low.
-
UFRGA Series -
Shimadzu Corp.
The Ultrafast RGA system utilizes the new Barrier Discharge Ionization Detector (BID) technology coupled with Nexis GC-2030 to create new system GC for ultrafast, high-sensitivity analysis. Since the electrode creating Helium plasma is totally isolated from the carrier gas, there is no chance to contaminate this electrode with a dirty sample. This enables long-term stability.
-
5100 Percent Oxygen -
Bacharach, Inc.
The Neutronics 5100 Percent Oxygen Analyzer is a compact analyzer designed for percent oxygen gas measurement. This analyzer features a rapid-response mini-zirconia sensor with a measurement range of 0 to 100% oxygen. Extremely high accuracy and single point calibration make this analyzer a low-maintenance solution that delivers reliable performance for critical process control applications.
-
pQA -
Hiden Analytical Ltd.
The Hiden pQA portable gas analyser is a versatile mass spectrometer and offered with a range of interchangeable sampling inlets to suit a broad application range. MIMS inlets are offered for analysis of dissolved species in ground water, sediments, fermentation cultures, soil samples, and general applications where analysis of dissolved species in liquid sample is required.
-
PDRM2 -
Bacharach, Inc.
The Parasense PDRM2 Portable Refrigerant Monitor is a robust single channel monitor designed with flexibility in mind allowing ease of transport and mounting to a piece of equipment or in a confined space for safety purposes. Built for accuracy and reliability, the monitor uses unique infrared absorption technology and combines different sensing techniques for dual gas species detection.
-
PRTrans1000 -
MadgeTech, Inc
The PRTrans1000 is rugged, submersible transient pressure data logger that records time and date stamped transient pressure event data at user-defined intervals and threshold triggers. Its stainless steel enclosure is designed for use in harsh, industrial environments. Features a ¼" NPT fitting for easy connection to gas, water, steam and hydraulic pressure lines.
-
ST120 TO-5 -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 1.2mm x 1.2mm in a TO-5 package. Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.
-
ST60 TO-5 -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a TO-5 package. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.
-
ABB Ltd.
The robust design of ABB’s vortex flowmeters provides high performance and reliability in liquid, gas and steam measurements. Equipped with digital signal processing (DSP) and advanced filtering techniques, these innovative flowmeters from ABB allow excellent flow signal detection and provide measurement immunity from the effects of hydraulic noise and pipeline vibration.
-
Dantec Dynamics A/S
Planar laser-induced fluorescence (PLIF) is an optical diagnostic technique widely used in fluid and gas applications. PLIF has proven to be a valuable tool for flow visualization as well as for quantitative whole-field measurements of scalars such as concentration and temperature in liquid and concentration in gaseous flows. Applications can be found in process engineering, biomedical engineering, and fluid dynamics research.
-
Ultima ID Pro RI-700H -
Bacharach, Inc.
The Neutronics Ultima ID Pro RI-700H Refrigerant Analyzer enables fast, accurate testing of refrigerant for HVAC/R applications. The Ultima ID Pro RI-700H reduces the need for costly and time-consuming gas chromatography. Improved accuracy and the ability to test a wide variety of refrigerants make this an essential tool for pre-screening refrigerant prior to consolidation and reclamation.
-
Model 6400TSG -
Teledyne Analytical Instruments
The 6400TSG series utilizes our field-proven ultraviolet (UV) fluorescence technology to continuously monitor the total sulfur content found in process gas and liquid feeds. UV-Fluorescence is a non-consuming method of detection, eliminating the hassles associated with replacing tape cartridges, and enables detection as low as 10 ppb, depending on application, with stable, reproducible results.
-
LSC series -
HORIBA, Ltd.
HORIBA's best-selling baking system has been developed to meet the requirements of today’s high technology industries. Without the need of a carrier gas, the system can provide stable vaporization of materials such as TEOS (at a rate of 600 SCCM) and H2O (at a rate of 2 SLM). For ease of access all device maintenance can be performed from the front of the unit.
-
ESPP-MIT1 Sensor -
ES Systems
ES Systems has developed a series of strain gauge pressure transmitters featuring very good accuracy at a low cost. Each module is based on an all-welded hermetically sealed structure in a single stainless-steel piece. The ESPP-MIT1 is a medium isolated pressure sensor suitable for gas or fluid pressure measurements in harsh industrial or HVAC environments.
-
CP RC -
OMICRON electronics
For HV testing OMICRON’s CPC 100 + CP RC are directly connected to the voltage transformer of the GIS, forming a resonance circuit. This reinforced “Power VT” is an integrated part of the GIS. So the need for draining and refilling any SF6 gas is eliminated. Acting as both the measuring and controlling device, the CPC 100 injects the required energy.