Filter Results By:

Products

Applications

Manufacturers

Gas

1) fills any space it's contained in and is amorphous. 2) liquid fuel powering vehicles.

See Also: Dissolved Gas, Gasoline, Ammonia


Showing results: 1306 - 1320 of 1357 items found.

  • Metal Tube Float Flow meter

    F56 - Beijing Airport Beiguang Instruments Co., Ltd

    F56 Metal Tube Float Flow meter Series are used for measure instantaneous and accumulated flow rate of liquid, gas and steam in closed pipelines. It is suitable for metering flow value on site or electronic remote. The measuring principle is based on the hydrodynamic effects,This makes float moving from bottom to top in vertical Pipe. As the displacement of float is in related to flow rate, which can be read from the indicator by means of the magnetic drive system in non-contact form . Also, flowmeters output electrical signal (4-20)mA / hart communication protocol with high / low limit Warning switches/integrating flow PCB broad can be configured.

  • High Power Narrow Linewidth Laser

    AULLD series - Amonics Ltd.

    Amonics' high power narrow linewidth laser (AULLD series) is integrated with Redfern Integrated Optics (RIO) PLANEXTM high performance external cavity laser. It features narrow linewidth, low phase noise, ultra low RIN, high output power with exceptionally reliable performance. The turnkey microprocessor controlled benchtop AULLD provides alarms and status indicators. An integrated RS232 or Ethernet computer interface provides easy control, diagnostic functions and data acquisition. It is particularly suitable for commercial fiber optic sensing applications, such as interferometric and Brillouin DTSS sensing systems for oil & gas, security, metrology and smart infrastructure.

  • Calibration Test Pumps

    Ralston Instruments

    High-precision calibration & pressure testing is the key to success in the oil & gas, petrochemical, maritime, pharmaceutical and aerospace industries and the right calibration tools make all the difference. Ralston Instruments offers a wide array of intelligently designed, high-quality calibration test pumps that simplify complex calibration processes while providing fast, accurate results. All Ralston pressure test pumps are lightweight, extremely durable, and easy to disassemble and repair with standard hand tools. And for quick connectivity with the most effective results, they all come with Ralston Quick-test™ adapters for safe, stable, leak-free connections without the need for a wrench or thread tape.

  • 2-in-1 High-Voltage Test Hood

    LX-HVE900EC - LXinstruments GmbH

    The test cells are made of stable, highly insulating plastic and are closed by a swiveling, transparent cover. The built-in safety switch is used to lock the hood and release the high-voltage sources. This ensures that no high voltage is active when the door is open. There is a generously dimensioned wiring space in the floor of the test cage. An interchangeable adapter plate in the test cell - optionally with an interchangeable interface or an interchangeable adapter cassette - allows quick adaptation to different types of test items. Prepared openings enable connectors and other common interfaces or cable bushings to be easily attached. The hood is opened and closed almost effortlessly thanks to precisely coordinated gas springs.

  • Radiometer

    X1-1-RCH-116-4 - Gigahertz-Optik GmbH

    The X1-1 radiometer from Gigahertz-Optik features an RCH-116-4 detector and is ideal for measurement of the irradiance of high power LEDs in the UV-A and blue light range. The device can accurately measure irradiance levels of up to 40,000 mW/cm². One of the outstanding features of the RCH-116-4 detector is its proven concept of a passive radiation absorber coupled to a UV sensor. This provides stability even in high temperature and intense UV radiation environments. In addition to the passive radiation absorber, the device also has a cosine-corrected field of view. The sensor’s housing also serves as a handle. The battery-powered X1-1 optometer supports a usable dynamic range from less than 1 mW/cm² to 40,000 mW/cm² thanks to its high-end signal amplifier. It can be used to perform precise measurements of up to 5 standard LED wavelengths for which the detector was calibrated for active irradiance. In addition to the CW measurement function, the device also has a dose measurement function. The radiometer can be used with other detectors from the RCH series. e.g. for gas discharge lamps. Remote control of the device is possible via its user software and a software development kit is offered for integration of the device in the user’s own software.

  • Digital "A" Flow Controller for Low Flow​

    HFM-D-300A / HFC-D-302A - Teledyne OEM Solutions

    HFM-D-300A / HFC-D-302A mass flow instruments have flow ranges from 0-5 sccm to 0-25 slm; use all metal seals, provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.

  • High Performance Liquid Chromatograph Triple Quadrupole Mass Spectrometer

    LCMS-8045 - Shimadzu Corp.

    Equipped with a heated ESI probe, the LCMS-8045 has the highest sensitivity in its class. The heated ESI probe, high-temperature heating block, desolvation line (DL) and drying gas, all act to promote desolvation and prevent contamination due to the penetration of liquid droplets into the MS unit. This improves the robustness, so reliable and high-accuracy data can be obtained over the long term. The LCMS-8045 also achieves the world's fastest scan speed (30,000 u/sec) and polarity switching speed (5 msec). These enable ultra-high-speed, high-sensitivity analysis. The excellent cost performance of this system is demonstrated in food safety, environmental analysis, and other quantitative analyses, it can be upgraded to the LCMS-8060.

  • Desktop Spectrometer

    Electro-Technic Products, Inc.

    The RSpec Explorer is an educational tool which makes it possible for an entire class or lecture hall to study atomic emission spectra. This is a great device for hands-on student learning including having students identify the gas in an unknown spectrum tube. Your students will find the software (included) is easy to use right out of the box. Until now, it’s been nearly impossible to teach about light and color using traditional tools like diffraction gratings because you can’t determine if all your students are even seeing the same results of their experiments. But with the RSpec-Explorer’s camera and software system, you will be confident knowing that every student is seeing the same thing.

  • Power Meter

    2015 PM - Standard Electric Works Co., Ltd

    ● Determine the running cost of your appliances.● Measure voltage, current, frequency, watt, power factor, and greenhouse gas emissions.● Log and Recall function.● Enable users to read the data in memory directly on the meter without connecting to a PC. ● Optical USB to RS-232 data transmission.● 2 Optical LEDs are built-in for data transfer.● Transferring and showing real-time data to a PC.● Make informed decisions when purchasing appliances and equipment.● Reduce your electricity bill.● Calculate electrical expenses by real, hour, month.    ● Data communication function.● Freely set upper and lower limit for V, A, W and alarm when measured value is out of limit.● Backlight function.

  • Miniature Zirconia Oxygen Analyzer with Pump to be DIN Rain Mounted as a True OEM

    Rapidox 1100Z-OEM-RSB & 1100ZR3-OEM-RSB - Cambridge Sensotec Ltd

    The new Rapidox 1100Z-OEM-RSB is the World’s first miniature zirconia oxygen analyser with pump designed to be DIN rail mounted into customer’s equipment as a true OEM. The Rapidox 1100-OEM-RSB is a cost-effective 24Vdc OEM version of our sampling 1100 zirconia analyser range. The package has been shrunk down and simplified to fit onto a DIN rail in an electrical cabinet, and comprises a compact control unit (with or without OLED display and menu keypad), a zirconia sensor with sample connection points, a particle filter and a powerful miniature sample pump capable of drawing a gas sample at up to 1.5 litres per minute through 6mm OD/4mm ID flexible tubing.

  • Pneumatic Test Pump Kit

    700HPPK - Fluke Calibration

    The Fluke Calibration 700HPPK Pneumatic Test Pump Kit generates and adjusts pneumatic pressures up to 21 MPa (3000 psi), without requiring a nitrogen bottle or other external pressure supply. It supplies pressure to devices under test (DUTs) that include transmitters, controllers, pilots, digital and analog gauges, and more. It’s the perfect solution for generating high pressure in the field, where conditions and operating surfaces can vary. The 700HPPK is the ideal choice for calibration technicians, test engineers, and instrument technicians working in industries like natural gas transmission and distribution, process, aerospace and defense, who need a simple-to-use, safe and portable pressure source that they can depend on in a wide variety of conditions.

  • Wide Range Vacuum Gauge

    HVG-20​​20B - Teledyne Hastings Instruments

    The HVG-2020B wide range, dual sensor vacuum gauge takes measurement to the next level. With a Piezo based sensor and a thermal based Pirani sensor accurately and confidently measure pressures across seven decades. The Piezo sensor is media isolated, gas composition independent, and periodically zeroed by the Pirani sensor. An ambient thermal sensor enables the instrument to adjust for temperature and therefore better accuracy.The optional touchscreen display, free windows data acquisition software and a variety of digital communication paths makes the HVG-2020B flexible and user friendly. Whether you need USB, RS 232, RS 485, linear or log outputs, graphical displays for data acquisition logging, this wide range gauge can perform.

  • Power Meter

    8015 PM - Standard Electric Works Co., Ltd

    ● Determine the running cost of your appliances.● Measure voltage, current, frequency, watt, power factor, and greenhouse gas emissions.● Optical USB to RS-232 data transmission.● 2 Optical LEDs are built-in for data transfer.● Transferring and showing real-time data to a PC.● Make informed decisions when purchasing appliances and equipment.● Reduce your electricity bill.● Calculate electrical expenses by real, hour, month. ● Can make different kinds of plugs for different countries / areas, such as Type B, E, G, I plugs.....etc.● Data communication function.● Freely set upper and lower limit for V,A,W and alarm when measured value is out of limit.● Backlight function.

  • Ultra-thin Mass Flow Controller

    DZ-100 - HORIBA, Ltd.

    The DZ-100 inherits the same CRITERION™ technology—a differential pressure detection system for laminar viscous flow ranges—used on HORIBA STEC’s MFC, the D500. This innovative technology controls the mass flow of various gases with high precision. As with the D500, the user-configurable DZ-100 supports multi-range and multi-gas applications. The compact design of the MFC reduces the internal volume of the internal gas flow path, and the optimized control algorithm improves response characteristics. It uses a compact CPU with high processing capacity, and the piezo drive circuit and control CPU are installed in the MFC module while the power supply components are housed in a separate small control box. Up to four MFC modules can be controlled by connecting them with the dedicated miniature connectors.

  • Laser Open Path H2S Detector

    GD1 - Teledyne Gas & Flame Detection

    The GD1 has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from offshore production facilities to wastewater treatment plants. At the heart of the detector is a tuneable laser diode that eliminates environmental effects from sun, rain and fog. The laser scans single absorption lines where there is no interference from other gases.The GD1 needs no recalibration and can replace multiple standard detectors to cover the same risk. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved while providing unparalleled service life and detector stability, thus saving on maintenance and service costs.Supplied with worldwide hazardous area approvals. Suitable for use in systems with SIL 2 requirement.

Get Help