M9186A -
Keysight Technologies
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
GX3104 -
Marvin Test Solutions, Inc.
The GX3104 is a precision 3U PXI module that forces and senses both voltage and current over a range of ±20 V and up to ± 1 A ( channel 1) with channels 2- 4 capable of supplying up to 500 mA. Total available output current from the module is 1A. The four channels are electrically isolated from the PXI power supply and share a common, isolated ground.
-
52403P -
Chroma ATE Inc.
Chroma's 52403P is a PXI Express Short Pulse SMU (Source/Measure Unit) designed for fast, precise and reliable sourcing and measurement of thermo-sensitive devices such as high-power laser diodes (LD). Integrating a high-speed pulser, a high precision SMU and a DAQ module into a single PXIe SMU, the 52403P can measure both the LIV and the low-level leakage current of a high-power LDs.
-
52400 series -
Chroma ATE Inc.
Hybrid Compatible PXIFour quadrant operationHigh source/measurement resolution (multiple ranges)Low output noiseHigh programming/measurement speed (100k s/S) & slew rateOptional measurement logDIO bitsOutput profiling by hardware sequencerProgrammable output resistanceFloating & Guarding output16 Control Bandwidth SelectionMaster / Slave operationDriver with LabView/LabWindows & C/C# APISoftpanel GUI
-
Guildline Instruments Ltd
DC Precision Current Sources provides precise and very stable output currents from 3 A to 10,000 A. The 6623A-PCS Series provides the best uncertainties of any DC high current sources (i.e. < 5 ppm of precision and stability at 1000A). In addition this Series is modular and initial output currents can be expanded at any time.
-
CCS-BTA -
Vernier Software & Technology, LLC
The Constant Current System is a DC power source with a built-in current probe designed for use in electrochemistry experiments.
-
-
Chroma 87001 -
Chroma Systems Solutions, Inc.
Chroma 87001 Battery Cell Simulator is a high precision, programmable, and bidirectional DC power source with both voltage source and current source functions. In addition, the model can be used as a multi-channel DC power supply or an electronic load as well. A single simulator has 16 channels and each of them can set voltage and current respectively via Chroma software.
-
AK-10 -
Amperis sl
The new AK-10 three-phase relay test equipment from Amperis features AC and DC Voltage Source ; AC Current Source ; AC/DC Auxiliary Power Source ; 8 possible configurations.
-
SpikeSafe Performance Series -
Vektrex Electronic Systems
SpikeSafe™ Performance Series Current Sources supply DC and precision continuous or single pulse current for light measurement and other applications. With sustained output power and no duty cycle limitations, Performance Series Current Sources support a broad range of applications.
-
PDX-1/7 -
Langeo Co., Ltd.
PDX-1 and PDX-7 DC rechargeable power source is available for resistivity/IP survey, light and portable with high voltage and large current.
-
Shenzhen Setec Power Co., Ltd.
A type of power inverter that converts DC (direct current) power from batteries or other DC sources into AC power that can be used to power a wide range of electronic devices and appliances
-
TH1775 -
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
AK-30 -
Amperis sl
AC voltage source with 4 channels, current source and aux with 6 channels. DC source can be used simultaneously. Amplitude, frequency and phase angle can be adjusted respectively, independently and continuously; Control via PC via Ethernet RJ45 interface
-
TEST-330B -
Beijing GFUVE Electronics Co.,Ltd.
Three phase secondary current injection test set is testing relay set, protective device, instruments, output ac dc current and voltage source, embedded Window XP system.