Filter Results By:

Products

Applications

Manufacturers

Temperature Chambers

Life test cycling of temperature accelerating electronic degradation.

See Also: Environmental Chambers, Chambers, Humidity Chambers


Showing results: 286 - 300 of 342 items found.

  • Multi Channel Optical Fibre Verification

    LXinstruments GmbH

    The multi-channel optical fibre test system is used in the development and qualification of single mode optical fibres. The fibres are exposed to environmental influences in a climatic chamber in order to analyse the data on insertion loss and reflection. In addition, the current temperature in the climatic chamber is documented. Insertion loss measurement is performed with the help of an optical power meter, laser sources and optical switches. An Optical Time Domain Reflectometer (OTDR) from Exfo is used for the reflection measurements. The system was designed for the simultaneous characterization of 15 sample fibres and one reference fibre.

  • Temperature Humidity Logger

    IM3700 Series - Ajinkya Electronic Systems

    We offer IM3700 Series Temperature / Humidity Loggers that are highly versatile monitoring & recording units. These can accept input from different type of humidity sensors as well as RTD sensor for Dry Bulb / Wet Bulb measurement technique. Moreover, these loggers can be used for monitoring of clean rooms, green rooms, server rooms, storage rooms & environment chambers in various industries, such as pharmaceutical, textile, cement, & logistics.

  • High Temperature Un-Cooled Extensometers (700 C)

    Model 7642 - Jinan Testing Equipment IE Corporation

    These extensometers use a high-temperature capacitive sensor and do not require any cooling. They will operate up to the maximum temperature limit of most environmental chambers used in materials testing. The Model 7642 is ideal for testing composites, metals and high temperature polymers in tensile, compression or cyclic testing. All units can be displaced in both compression and tension. The extensometer is supplied with the advanced DT6229 controller. The standard output is 0-10VDC analog signal, factory calibrated with the extensometer. This system provides a number of functional enhancements, including high speed digital output, built in calibration and tare functions, analog and digital filters, and more.

  • Walk in Chamber for Altitude Simulated Test

    Guangdong Bell Experiment Equipment Co.,Ltd

    Walk in Chamber for Altitude Simulated Test Relative Standard test requirementsTest Object: battery pack and systemTest Conditions: Altitude 4000m or the equate air pressure condition, atroom temperature.The test objects stay in the test condition as Item 2 for 5 hours.Subject the test object to 1C(no more than 400A) constant current discharge until reaching the cutoff condition.After testing, observe for 2h under the room temperature.

  • IP X5, X6 - Walk-In Rain Test Chamber

    ACMAS Technologies Pvt. Ltd.

    WEIBER designs and manufactures standard as well as customized water spray test chamber for evaluating various automotive, electrical and electronics items under water, rain or shower conditions. The chamber interrogates the performance of parts when subjected to water droplets.The system is based on the IP X5, X6 specification requirements, and can also accomplish individual automaker’s tests, as well as electrical-enclosure tests.Our system uses multiple control solenoids to vary the water's spray volume/pressure. A holding tank prepares the water to the desired temperature, if required. A pump ensures the water is delivered in the proper pressure range.

  • Wafer Bonder

    AML - OAI

    Wafer bonding has found many applications in the field of MST, MEMS and micro engineering. These include the fabrication of pressure sensors, accelerometers, micro-pumps and other fluid handling devices. The process is also used for first-order packaging of silicon microstructures to isolate package-induced stresses. The OAI AML Wafer Bonder facilitates both the alignment and bonding to be performed in-situ, in a high vacuum chamber. For anodic bonding the wafers are loaded cold and heated in the process chamber. For high accuracy alignment the wafers are aligned and brought into contact only after the process temperature has been reached, thus avoiding differential thermal expansion effects which can compromise alignment. The AML Wafer Bonder is excellent for anodic bonding, silicon direct and thermal compression bonding applications. These features enable the bonder to be used with virtually any processing tool.

  • Compact TLP/VF-TLP/HMM Probearm Set for Temperature Measurements

    PHD-4001A - High Power Pulse Instruments GmbH

    *Electrically isolated probearm kit for VF-TLP, TLP, HMM, HBM force and sense probingbased on the GGB Picoprobe Model 10 replacement probe tips*Buried coaxial cable channel for thermo-chuck in isolated chamber temperature measurements*Compatible with GGB Picoprobe Model 10 replacement probetips*Compatible with all standard micropositioner interfaces*High precision rotation of the probearm by backlash-free 80:1 gear*Rugged stainless steel design*SMA connectors

  • Environmental Testing

    dB Technology Ltd.

    We have a CTS C-65/100 Climatic Test Chamber available for hire at dB Technology.They have available:*Internal dimensions: 500 x 500 x 400mm (w x h x d)*Temperature range: -65°C to +180°C*Heating rate: 3°C/min*Cooling rate: 2°C/min*Climatic temp range: +10°C to +95°C*Humidity Range: 10 to 98% RH

  • Magnetic System

    NMR-EA300 System - Caylar

    The NMR-EA300 system is the reference for calibrating magnetic sensors. It allows to generate an absolute magnetic field at <±10mG (0.1 uT) without temperature drift (<0.1ppm/C°) over a range from 14mT to 3T. This system is composed of an EA300 electromagnet with NMR poles, a MPU-16U ±150A ±70V current source of class 1ppm and a NMR20 Teslameter with a magnetic field controller (FR020).A thermostat chamber can be installed in the air gap (Optionally available on 50mm and 70mm gap poles).

  • Halt Hass Chambers

    ACMAS Technologies Pvt. Ltd.

    HALT and HASS chambers from WEIBER provide extreme temperature & vibration capabilities used during the product design and manufacturing cycles to compress the time normally required to identify design and process weaknesses. HALT techniques are important in uncovering many of the weak links inherent to the design and fabrication process of a new product. HASS techniques are incorporated during the production phase to find manufacturing process defects that could cause product failures in the field.

  • Total Sulfur Analyzer​​​

    Model 6200T​​​ - Teledyne Analytical Instruments

    The Model 6200T Total Sulfur Analyzer utilizes proven UV fluorescent technology to continuously detect sulfur found in inert gas streams. An internal, quartz catalytic converter is employed to convert the sulfur, when mixed with scrubbed ambient air, into SO2 via higher temperature oxidation. An internal vacuum pump is employed to draw both the sample and the ambient air into the converter. The converted sample gas is fed to the fluorescence chamber where it is then exposed to ultraviolet radiation.​

  • Short-wave Infrared Camera

    Goldeye CL-008 Cool - Allied Vision Technologies

    The Goldeye CL-008 is one of the fastest QVGA resolution short wave infrared (SWIR) cameras with Camera Link interface. With frame rates up to 344 fps at full resolution, versatile application fields can be addressed and processes can be sped up strongly. To enable low-noise imaging in the spectral range from 900 nm to 1700 nm, the camera is equipped with a nitrogen filled cooling chamber. It enables the thermo-electric cooler (TEC) to operate the sensor at a temperature of 5o C and avoids condensation.

  • Sand and Dust Testing

    National Technical Systems

    NTS operates some of the largest and most accurate sand and dust testing chambers available in the industry. We can accommodate parts in excess of 8 ft3 (0.25 m3) and comply with the requirements of various regulatory standards. While sand or dust circulate at up to 40 mph (65 kph) we can modify the test according to your special requirements, including running at temperatures of up to +200°F (+95°C). A calibrated “hopper” which assures that an adequate amount of contaminant is entering into circulation manages the input to the chambers. In addition to measured inputs, NTS employs an electronic beam, which determines that there is the right mixture of sand or dust and air in the test medium at any given time. This enables our technicians to adjust for loss in real time, and make corrections to ensure that the test article is exposed to the harmful particulate matter for the requisite amount of time.

  • Insect Rearing Chamber - One Door Model

    IRC20 - Canden Products LLC

    IRC20- ONE DOOR INSECT REARING CHAMBERThe IRC20 one door insect rearing chamber is used by scientists in many research areas, from genomics to clinical epidemiology and species conservation. This chamber not only can be used in drosophila research but also in many types of insect growing projects.Chamber features all stainless steel interior and exterior construction with 2″ polyurethane CFC free insulation.Cabinet standard featuresStainless Steel Exterior & InteriorMaintains temperatures between 10°c to 40°cTemp and Humidity controller that displays both PV/SVLED interior light with programmable digital diurnal timerRecessed Door HandleDoor locks standard2″ access portMagnetic door gasket standard for positive door sealPre-Installed 4″casters with bumper brakesThree (3) Pre-Installed shelves per sectionBack wall plenum for even distribution of conditioned airn goes here.

  • Walk-In Test Chamber

    Sanwood Environmental Chambers Co ., Ltd.

    Energy-saving design: Adopting PID + PWM principle of VRF (refrigerant flow control) technology to achieve low-temperature energy-saving operation (electronic expansion valve according to thermal energy conditions refrigerant flow servo control technology) low temperature working state, the heater does not participate in the work, through PID + The PWM regulates the flow rate and flow direction of the refrigerant, and regulates the three-way flow of the refrigerant pipe, the cold bypass pipe, and the hot bypass pipe to achieve automatic constant temperature to the working chamber. This method can reduce energy consumption by 30% under low temperature conditions. The technology is based on Danish Danfoss' ETS series of electronic expansion valves, which can be used to smoothly adjust the cooling capacity for different cooling capacity requirements, that is, to achieve the compressor cooling capacity adjustment when different cooling rate requirements are met.

Get Help