Filter Results By:

Products

Applications

Manufacturers

Fixtures

orient and afix UUT.

See Also: Fixturing, Test Fixtures, Mechanical Fixtures, Vacuum Fixtures, Jigs


Showing results: 646 - 660 of 699 items found.

  • PC Based Test Setup for LED Driver of LED

    SCR ELEKTRONIKS

    The tests are Performed as Prescribed in IS the Panel Carries out high voltage, open circuit and performance tests, one by one and provides indication of the Test results as PASS or FAIL lamp for high voltage test. It is very useful and handy in line testing on Mass production line as well as type Testing. Special fixture can be provided for the specific product. This avoids the connections & disconnections of the product for different tests. The total time for entire testing is less than 80 seconds. Micro controller based sequential timer maintains the sequence of operation and displays the test status. The entire system is housed in sturdy M.S cabinet with powder coating.

  • SHC68-C68-D4 Shielded Single-Ended Cable, 0.55 m

    781013-01 - NI

    68-Pin, Male VHDCI to 68-Pin, Male VHDCI, 50 Ω, 0.55m, Shielded Digital Cable - The SHC68-C68-D4 Digital Cable connects NI 6535/6/7, 654x, 655x, and 657x digital instruments with other NI accessories like the CB-2162 Connector Block or SMB-2163 Terminal Block. You can also use it with certain Digital I/O Adapter Modules for FlexRIO, Digitizer Adapter Modules for FlexRIO, Signal Generator Adapter Modules for FlexRIO, and high-speed serial instruments. It is flexible and easily fits around custom test fixtures and other equipment. It is a shielded, 50 Ω cable and is offered in different lengths.

  • Spectrum Analysis, Up To 70 GHz

    S930907B - Keysight Technologies

    The S930907B spectrum analysis (SA) adds high-performance microwave spectrum analysis to the N522xB/N524xB PNA family up to 70 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Enhanced Time-Domain Analysis With TDR

    S95011B - Keysight Technologies

    This application enables the analyzer to perform enhanced time domain analysis for high-speed data applications. All functionality of the S95010B are included (TDR/TDT mode). In addition, the S95011B enables more detailed measurements and evaluations, such as eye-diagram / mask modes, without adding PLTS software. Jitter and emphasis / equalization capabilities enable simulation of real-world signals and environment. The S95011B covers up to 53 GHz bandwidth. Full calibration is available and the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, mechanical calibration kits or ECal with DC option (i.e., N469xD or N4433D with Option 0DC) are recommended.

  • Spectrum Analysis, Up To 26.5 GHz

    S930902B - Keysight Technologies

    The S930902B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 26.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • PXI 10A Fault Insertion Switch 6-chan 2-bus

    40-192-012 - Pickering Interfaces Ltd.

    This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.

  • PXIe-5650, 1.3 GHz RF Signal Generator

    781215-01 - NI

    The PXIe‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXIe‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • PXI-5650, 1.3 GHz RF Signal Generator

    779670-00 - NI

    The PXI‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • Enhanced Time Domain Analysis With TDR

    S96011B - Keysight Technologies

    Use S96011B to perform enhanced time domain analysis for high-speed data applications. Includes all functionality of the S96010B (TDR/TDT mode). In addition, the S96011B enables more detailed measurements and evaluations, such as eye diagram / mask modes, without adding PLTS software. Jitter and emphasis / equalization capabilities enable simulation of real-world signals and environment. The S96011B covers up to 53 GHz bandwidth. Full calibration is available and the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, use mechanical calibration kits or ECal with DC option (i.e. N469xD or N4433D with Option 0DC).

  • Spectrum Analysis, Up To 13.5 GHz

    S930901B - Keysight Technologies

    The S930901B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 13.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • 9-Pin Male D-Sub to 5-Pin Female Screw Terminal, Breakout for CAN Terminal Block

    780041-01 - NI

    9-Pin Male D-Sub to 5-Pin Female Screw Terminal, Breakout for CAN Terminal Block - The CAN Breakout Box works with high-speed, low-speed, and single-wire controller area network (CAN) devices or PC interfaces. It features 14 ports for connecting devices with cables or directly to wiring harnesses. With an onboard power supply, the CAN Breakout Box can place power on the V+ pin required by some CAN transceivers. With a switch on the front panel, you can select 120 Ω, 60 Ω, or no termination on the network. You can use the CAN Breakout Box in desktop applications or mounted on a DIN Rail for test fixtures and cabinets.

  • Spectrum Analysis For E5081A Up To 20 GHz

    S960904B - Keysight Technologies

    The Keysight S960904 spectrum analyzer (SA) software application adds high-performance spectrum analysis to the E5081A ENA-X up to 20 GHz. With fast-stepped FFT sweeps resulting from optimized data processing, the SA software application provides quick spurious searches over broad frequency ranges. The application enables simultaneous spectrum measurements using test and reference receivers. The multichannel SA pairs with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application uses source-power and receiver-response calibration and fixture de-embedding, providing highly accurate in-fixture and on-wafer spectrum measurements.

  • XRF

    L Series - Bowman

    The L Series is the most versatile instrument that Bowman offers. It combines all of the features of the P Series with a larger sample chamber and greater X-Y stage travel. For samples larger than ~12 inches (300 mm) in any direction, the L Series is a must-have. The large sample stage and travel allows for both large parts, or large sample fixtures holding multiple parts, to be measured. The chamber is fully enclosed and boasts a capacity to hold samples up to 22″ (550mm) x 24″ (600mm) x 13″ (330mm) (LxWxH). The X-Y stage travel distance is 10″x10″ (254mm x 254mm). The standard configuration includes a 4-position multiple collimator assembly, and a variable focus camera allowing for measurement in recessed areas. As with other models, the collimator sizes and focal distances are customizable for different customer applications. The programmable X-Y stage is included, but can be removed to allow for the maximum sample height capacity (10″ (254mm) z-height with stage, 13″ (300mm) without). The solid-state PIN detector is included along with our long-life micro-focus x-ray tube. The high performance SDD detector is an optional upgrade.

  • Custom solutions

    NOVACAM Technologies, Inc.

    Novacam develops custom interferometric solutions to address particular inspection and imaging needs of specialized applications and OEM markets. Our modular interferometer components offer a superior and cost-effective platform for developing high-performance systems and assemblies. We will collaborate with your application experts to devise the optimal combination of inteferometric (OCT) hardware, non-contact fiber-based sensor probes, and system software.As needed, Novacam engineers: develop customized optical probes and inspection stations develop inline probe fixtures for production environments adapt Novacam standard interferometer component modules to suit your application help integrate Novacam systems or components with third-party tools write customized software

  • Vector Network Analyzer

    SNA5000A - SIGLENT Technologies

    The SIGLENT SNA5000A series of Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz, with 2 and 4 port models available. Designed to give you instant insight into scattering, differential, and time-domain measurements. They are effective instrumentation for determining the Q-factor, bandwidth, and insertion loss filters and feature impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation, and adapter removal/insertion adjustments. There are five sweep types: Linear-Frequency, Log-Frequency, Power-Sweep, CW-Time, and Segment-Sweep mode. The SNA5000A series VNAs also support scattering-parameter correction of SOLT, SOLR, TRL, Response, and Enhanced Response for increased flexibility in R&D and manufacturing applications.

Get Help