Filter Results By:

Products

Applications

Manufacturers

Noise Sources

create signal disturbances for the purpose of noise instrument calibration.

See Also: Pink Noise, Noise Generators


Showing results: 226 - 240 of 258 items found.

  • 1000W Ferroresonant Power Supply

    Series PRR - Kepco, Inc.

    Kepco's PRR are 1000 Watt rack mounted laboratory systems power supplies that offer the low cost and very high dependability of ferroresonant voltage stabilization.The ferroresonant stabilizing technique provides extraordinary isolation from a wide variety of source noise. It is inherently short-circuit proof and cannot expose delicate loads to overvoltage hazards. Hence no crowbar, fuses, or bounding circuits are needed. Ferroresonant power supplies use no noise-producing switches or oscillators. Voltage setting is independent of delicate control settings or diode references and requires no comparators, references, or limiters. Efficiency is 70-80%.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • Multi-Channel Vector Signal Generators

    875 - Berkeley Nucleonics Corporation

    The Model 875 is an ultra-fast-switching vector-modulated signal source covering a continuous frequency range from 10 MHz to 40 GHz. The Model 875 offers switching speeds as fast as to 200ns, enables ultrafast CW frequency sweeps, chirping, intra-pulse modulation and pulse shaping, all with very low phase noise. A high-performance internal I/Q modulator enables customized modulation waveforms and supports dedicated modulation schemes such as avionics modulations. This newly engineered design couples extremely deep memory and wideband capabilities - making complex modulation affordable and easy to program.

  • RF Signal Generators

    Salicon Nano Technology

    As Rigol's RF first signal source, the DSG3000 series offers standard AM/FM/ØM analog modulation, as well as options for I/Q modulation and I/Q baseband output. The instrument is available with maximum frequencies of either 3 GHz or 6 GHz. Featuring a high signal purity with phase noise measuring <-110dBc/Hz@20kHz (typical) and a wide output range of -130dBm to +13dBm, the DSG3000 RF signal generator has standard pulse modulation with an on/off ratio of up to 80dB, with optional pulse train generator available. The DSG3000 series also has an amplitude accuracy of <0.5dB (typical).

  • Multifrequency Clock Synthesizer - PMC

    Model 7190 - Pentek, Inc.

    - Simultaneous synthesis of up to 5 different clocks- 8 SMC clock outputs- Ideal for A/D and D/A converter clock sources- Typical phase noise: -125 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 or 10 MHz- Four quad VCXOs allow selection from 16 different base frequencies- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 500 MHz- Control and status via PCI bus interface

  • X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer

    MESA-7220V2 - HORIBA, Ltd.

    The MESA-7220V2 measures both sulfur and chlorine in petroleum based products using the Monochromatic Energy Dispersive X-ray Fluorescence (EDXRF) method. A monochromatic X-ray source is used in order to obtain an ultra-low noise background which affords the best detection limits for both sulfur and chlorine.The detector window size was increased to collect more fluorescent X-rays and thus achieve lower level ppm values. This provides excellent, repeatable performance at both low and high concentrations of both elements.By adjusting the angle of the graphite crystal, the excitation beam can be measured to excite sulfur in the sample, increasing sensitivity.

  • Triple Output DC Power Supply, 60V/3A (2x) & 5V/3A; 375W

    U8032A - Keysight Technologies

    Keysight now extends its range of basic DC power supplies to offer 375watt power range, making it an ideal power source alternative in electronics manufacturing, research and development as well as the education sector. The U8032A, basic DC power supply, is a manual triple-output power supply with sequencing capability. With this function, users can generate output sequences with minimal programming skills. Each power supply is also built with excellent load regulation and clean output noise for continued stability. With these and many other features, you get a solid and reliable triple-output power supply at an unsurpassed performance.

  • Triple Output DC Power Supply, 30V/6A (2x) & 5V/3A; 375W

    U8031A - Keysight Technologies

    Keysight now extends its range of basic DC power supplies to offer 375watt power range, making it an ideal power source alternative in electronics manufacturing, research and development as well as the education sector. The U8031A, basic DC power supply, is a manual triple-output power supply with sequencing capability. With this function, users can generate output sequences with minimal programming skills. Each power supply is also built with excellent load regulation and clean output noise for continued stability. With these and many other features, you get a solid and reliable triple-output power supply at an unsurpassed performance.

  • 1231a Very High Frequency Distribution

    Precise Time and Frequency, Inc.

    The ptf 1230A(1U)/1231A(2U) GPS L-Band RF Distribution amplifiers provide high performance GPS signal references for laboratory or systems use. In most applications the low noise and signal gain capability of the units will provide userswith a robust GPS signal source for lab or system requirements.The ptf 1230A/1231A uses individually buffered output stages and insures maximum isolation between the individual outputs. The ptf 1231A offers 12 outputs. Options are available for a 2U/3.5” version (ptf 1230A) with 24 outputs.Isolation from output to output is >-40 dB. The input also offers DCV for biasing an active antenna.

  • Data Acquisition Systems & Data Loggers

    imc Test & Measurement GmbH

    Whether it’s in a vehicle, on a test stand or monitoring equipment and machinery - imc data acquisition systems are easy to operate and will help you become more productive and profitable. Our products are suited for work in mechanical and mechatronic applications. They handle up to 100 kHz per channel, are compatible with almost all signal sources and sensors, and can measure nearly all physical quantities such as pressure, force, speed, vibration, noise, temperature, voltage and current. The spectrum of imc data acquisition systems ranges from simple data acquisition via integrated real-time calculations, to the integration of models and complete automation of test stands.

  • Measurement Hardware

    imc Test & Measurement GmbH

    Whether it’s in a vehicle, on a test stand or monitoring equipment and machinery - imc data acquisition systems are easy to operate and will help you become more productive and profitable. Our products are suited for work in mechanical and mechatronic applications. They handle up to 100 kHz per channel, are compatible with almost all signal sources and sensors, and can measure nearly all physical quantities such as pressure, force, speed, vibration, noise, temperature, voltage and current. The spectrum of imc data acquisition systems ranges from simple data acquisition via integrated real-time calculations, to the integration of models and complete automation of test stands.

  • High-Speed Precision SMU (100 FA, 60 V, 1 MSa/s)

    PZ2120A - Keysight Technologies

    The Keysight PZ2120A is a cost-effective, high-speed precision source / measure unit (SMU) featuring best-in-class narrow pulse width, fast Digitizer Mode, and seamless current measurement ranging. It enables narrow-pulsed measurements and fast dynamic measurements with a wide dynamic range for a wide range of emerging applications such as vertical-cavity surface-emitting laser (VCSEL) optical devices and integrated circuit (IC) testing. In addition, its low measurement noise performance enables measurements with shorter aperture times, and its seamless current measurement ranging function enables a wide dynamic range and eliminates range change time, which improves test throughput.

  • High-Speed Precision SMU (100 FA, 60 V, 15 MSa/s)

    PZ2121A - Keysight Technologies

    The Keysight PZ2121A is a high-speed precision source / measure unit (SMU) featuring best-in-industry narrow-pulse width, fast Digitizer Mode, and seamless current measurement ranging. It enables narrow-pulsed measurements and fast dynamic measurements with a wide dynamic range for a wide range of emerging applications such as vertical-cavity surface-emitting laser (VCSEL) optical devices, integrated circuit (IC) testing. In addition, its low measurement noise performance enables measurements with shorter aperture times, and its seamless current measurement ranging function enables a wide dynamic range and eliminates range change time, which improves test throughput.

  • LED Power Driver ATS

    8491 - Chroma ATE Inc.

    1. DC Electronic Load : Chroma 6310A/6330A Series2. Transducer Unit/Module*1 : Chroma A849101/A849102, A849103, A8491043. Time/Noise Analyzer : Chroma 80611 & 80611N card4. Sytem Controller*2 : Industrial PC5. DC Source: Chroma 62000P Series6. Digital Power Meter : Chroma 66200 Series7. OVP/Short Circuit Tester : Chroma 806128. ON/OFF Controller : Chroma 80613*1 : A849101 transfers UUT output signal to voltage signal, and measure by 84911 LED power driver measurement card (200kHz). The optional 80611N Noise card is required for 20MHz ripplecurrent measurement.*2 : The controller includes both 84911 LED Power Driver measurement card and 84903 control card.- 84911: Measure rms current, dimming current/frequency/duty, timing, power & ripple current (200kHz)- 84903 : Provide BL control signal(DC level, PWM, SM bus), and enable ON/OFF signal.C Source : Chroma 6500/61500/61600 Series

  • Silicon Detectors

    Edmund Optics Inc.

    Through the photovoltaic effect, detectors provide a means of transforming light energy to an electrical current. The root of the theory behind this phenomenon is a small energy gap between the valence and conduction bands of the detector. When light, with enough energy to excite an electron from the valence to the conduction band, is incident upon the detector, the resulting accumulation of charge leads to a flow of current in an external circuit. Since light is not the only source of energy that can excite an electron, detectors will have some amount of current that is not representative of incident light. For example, fluctuations in thermal energy can easily be mistaken for light intensity changes. A variety of these "non-light" contributions are present and, when summed up, make up the total noise within the detector.

Get Help