Picarro Inc.
Picarro Gas Isotope Analyzers - δ13C, δ15N, δ17O, δ18O, δD, Isotopic Carbon Dioxide, Isotopic Methane, Isotopic Nitrous Oxide, Isotopic Oxygen, Isotopic Water, etc.
-
RayMon10 -
Kromek Group plc
A powerful and rugged handheld gamma detector for high-resolution radioactive isotope identification. The RayMon10 is one of the most powerful and rugged handheld radiation monitors in the world. It can be used to detect, measure and accurately identify gamma-ray emitting radionuclides, providing high-resolution isotope identification using the latest CZT solid-state detector technology. It is an all in one solution to your gamma radionuclide identification needs
-
Thermo Fisher Scientific Inc.
Research, production and analytical laboratories worldwide rely on us for rapid, efficient qualitative and quantitative analysis. Our innovative instruments and user-friendly software serve a range of industrial, educational, environmental and health markets. We offer a comprehensive portfolio for the quantification and identification of trace elemental species at ppm to sub-ppt levels in addition to isotopes. We also provide a wide range of lab-based and handheld instruments employing analytical techniques including XRF, FTIR, NIR, Raman spectroscopy, IRMS, ICP-MS and more.
-
isoprime precisION (IRMS) -
Elementar Analysensysteme GmbH
Stable isotope analysis provides great insight into diverse applications and delivers a greater understanding of the micro and macro cycling mechanisms of the organic elements through the world around us. Though our collective knowledge continues to grow, so does our desire to explore further. The more we know, the more we question.
-
LI-7825 -
Li-Cor Environmental, Inc.
The LI-7825 measures the four most abundant CO2 gas isotopologues in air and reports δ13C , δ17O , and δ18O with high precision and accuracy.
-
Iso CHROM® LC -
Elementar Analysensysteme GmbH
Unlike the existing LC-inlet solution via chemical oxidation, the iso CHROM LC works with high-temperature combustion. It quantitatively converts organic carbon to CO2.In addition, the easy-to-use iso CHROM LC shows outstanding precision, accuracy, and linearity without significant peak broadening that can diminish the chromatographic performance. In continuous operation, virtually all peaks in a chromatogram can be analyzed for the stable isotope ratios of carbon.
-
LiquiFace -
Elementar Analysensysteme GmbH
Compound specific isotope analysis of aqueous samples by LC is highly advantageous for those compound classes which are thermolabile or require derivitisation prior to GC analysis. Samples such as carbohydrates, amino acids, alcohols, organic acids and peptides make ideal candidates for LC-IRMS and the technique has been employed to great success in food and biogeochemistry applications. The LiquiFace works as an interface for the LC system to provide quantitative on-line conversion of organic carbon to CO2 prior to analysis by the IRMS system. Isotopic precision, accuracy and linearity is exceptional due to the highly efficient quantitative conversion of the organic carbon to CO2. This level of performance means that the LiquiFace is able to cover a range of sample types with a complete independence upon sample concentration, making the analysts life even simpler.
-
iso FLOW -
Elementar Analysensysteme GmbH
The iso FLOW is the first complete platform solution for the analysis of trace and pure components of simple gases derived from air, carbonates, water, and life. Driven by a new concept in separation science, the UltiTrapTM permits cryogen-free concentration prior to dynamic chromatographic separation.
-
IRMS -
Elementar Analysensysteme GmbH
The most advanced software ever created for the stable isotope community, the IonOS® has been designed uniquely for stable isotope analysis and aims to save analysts time and money while at the same time facilitating consistent data generation. It provides exceptional automation and sophistication for GC and EA data processing. ArDB analytics software extends the envelope of data analysis beyond simply data processing. Perhaps more so than any other analytical technique, stable isotope ratio mass spectrometry is about comparison. Comparisons of one stable isotope to another; comparisons of a sample to a standard, and comparison of unknown samples to known samples within a database. With ArDB, we provide powerful new stable isotope data analytics tools.
-
D3S NET -
Kromek Group plc
The D3S NET radiation detector is a fast and accurate radioisotope identification device (RIID) for gamma isotope identification and neutron detection. The data collected by this radiation detector is not only shown to the user via the mobile phone app but also sent to a central control screen showing data from every other SIGMA enabled detector on the network. The D3S NET detector unit houses larger detectors that provide identification of isotopes in seconds, alerting the user and your command centre of gamma isotope source, dose and any neutron detection.
-
EA Inlets -
Elementar Analysensysteme GmbH
The combination of elemental analysis (EA) with isotope ratio mass spectrometry (IRMS) has allowed the explosion of stable isotope analysis across a broad range of application areas. This diversity in application areas means that our customers often have different demands of their EA-IRMS solutions and so we offer a range of elemental analysers for coupling to IRMS products.
-
8250-02 -
Li-Cor Environmental, Inc.
Expand your soil gas flux research to include CO2 isotope measurements. The Calibration Manifold works directly with the LI-7825, adapting it from atmospheric to soil gas flux capabilities. It is ideal for researchers who are interested in using an existing LI-7825 for soil gas flux applications or expand their current soil gas flux research with CO2 isotope measurements.
-
D3S PRD -
Kromek Group plc
The D3S PRD personal radiation detector is a high-speed PRD or SPRD replacement that is a cost-effective radiation detection and preliminary identification device for first-line users. It fits on your belt or even in your pocket giving you radiation alerts for gamma and neutron radiation plus the ability to identify what isotopes have been found. It is the only PRD that detects the presence of radiation and also displays the isotope identified and it does all this in seconds.
-
OS5400 -
ORTEC
This extremely stable and reliable system monitors concentrations of fission and activation products in reactor plant systems to detect degradation in the fuel boundary integrity based on key isotope activity levels and their relative abundances. The FINESS System is an excellent example of this type of system.
-
Model MSI-3000 -
TEK-VAC INDUSTRIES Inc.
The Tek-Vac MSI-3000 is a general purpose inlet system, utilized for introduction of precision gas quantities into a mass spectrometer for quantitative analysis.Combined with Tek-Vac's proprietary stainless steel passivation for nuclear applications, the MSI-3000 may be implemented in functions where handling and exposure to hydrogen isotopes is required.