Filter Results By:

Products

Applications

Manufacturers

VDE

Verband der Elektrotechnik


Showing results: 46 - 52 of 52 items found.

  • Phase Detector

    Paula - BAUR Prüf- und Messtechnik GmbH

    BAUR paula phase detector. The paula phase detector is used for clear phase identification in earthed and shorted medium and high-voltage cables. With the help of the measurement procedure tried and tested over many years, paula delivers precise phase allocation without scope for interpretation and corresponds to the highest safety standards for tasks on and close to electric equipment.* Clear phase determination possible in cable lengths up to 40 km* Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)* Suitable for all switchgear constructions due to compact design of the signal injectors* Ready for operation for up to 2 weeks (standby mode)

  • Insulation Meters

    PCE Instruments

    Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.

  • Installation Safety Testers

    PeakTech Prüf- und Messtechnik GmbH

    This innovative combination meter for testing electrical installations according to VDE 0100 convinces by its technical performance in the high-end range.With the large 3.5 "TFT color display all important safety checks as the RCD-, Voltage-, Loop-, Low-Ohm, Earth resistance and Insulation tests for annual safety-checks and newly installed systems can safely be carried out by the responsible electrical engineer.Since this new development was designed only according to the latest standards, the required measuring values can be even more convenient stored with an App (iOS / Android) via Bluetooth on the mobile phone, saved to an SD card or, when work is completed, from the internal data memory via USB connection to a PC.

  • [5kV AC] Hipot Tester, Rise/Fall-Time Control Function Equipped

    TOS5200 - Kikusui Electronics Corp.

    TOS5200 is designed for AC Hipot Test with 500 VA capacity and 200 mA short circuit current output capability. Equipped with the PWM amplifier, the TOS5200 can provide a stable & reliable output without being affected by ACpower line. Therefore, it is a perfect solution for electronic equipment or devices complied to IEC, EN, UL, VDE andJIS etc. requirement.As TOS5200 covers most of features of our upper class model for AC Hipot Test, it achieves thesuperb cost / performance ratio for those who need 200 VA or 500 VA capacity, or both. Also, as it equips the Interlockfunction together with other safety features, operator can carry out the test with higher current value in safe.

  • PCI Bus Analog Output Board, 8 Isolated Outputs, 14 Bit

    APCI-3501-8 - TEAM SOLUTIONS, INC.

    *8 analog output channels*Optical isolation 500 V*Settling time 30 µs typ.*14-bit resolution (13 bit for 0-10 V)*Output voltage: ±10 V, 0-10 V (switchable through software)*Output voltage after reset: 0 V*Each output channel has its own ground line (without optical isolation from the others)*Driver capacity: 5 mA/500 pF*Short-circuit protection, EMI filters*Noise neutralization of the PC supply*Creeping distance: 3.2 mm acc. to DIN VDE 0411-100*Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary*2 digital input channels, 24 V, isolated*2 digital output channels, 24 V, isolated

  • [5kV AC/6kV DC] Hipot and Insulation Resistance Tester, Rise/Fall-Time Control Function Equipped

    TOS5300 Series - Kikusui Electronics Corp.

    The "TOS5300 Series" is a series of test instruments used in Hipot (withstanding voltage) tests and insulation resistance tests, two of the four tests regarded as necessary for ensuring the safety of electrical products. With an output of 5 kV/100 mA (AC) and 6 kV/10 mA (DC), the series can be used in Hipot (withstanding voltage) & insulation resistance testing of electronic equipment and electronic parts, based on the requirements of IEC, EN, UL, VDE, JIS, and other international safety standards and the Electrical Appliance and Material Safety Law. Also, the test voltage stability is improved with the adoption of a newly developed switching amplifier. Since the output voltage can be kept constant even when the AC line voltage or frequency changes, consistent testing can be performed, even when the power supply environment is in an unstable region. The TOS5300 is also equipped with a number of features that are capable of meeting a variety of test needs. It is a new low-cost standard model that provides thorough operability, reliability and safety.

  • PCI Bus Analog Output Board, 4 Isolated Outputs, 14 Bit

    APCI-3501-4 - TEAM SOLUTIONS, INC.

    4 analog output channels Optical isolation 500 V Settling time 30 µs typ. 14-bit resolution (13 bit for 0-10 V) Output voltage: ±10 V, 0-10 V (switchable through software) Output voltage after reset: 0 V Each output channel has its own ground line (without optical isolation from the others) Driver capacity: 5 mA/500 pF Short-circuit protection, EMI filters Noise neutralization of the PC supply Creeping distance: 3.2 mm acc. to DIN VDE 0411-100 Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary2 digital input channels, 24 V, isolated 2 digital output channels, 24 V, isolated Noise immunity Test level: ESD: 4 kV Fields: 10 V/m Burst: 4 kV Cond. radio interferences: 10 V

Get Help