Showing results: 31 - 45 of 62 items found.
-
H2 -
Dwyer Instruments Inc.
Explosion-proof, UL & CSA Listed for Class I, Groups B, C & D and Class II, Groups E, F & G. The H2 is designed for sequencing two different actions as pressure of a liquid or gas increases or decreases. The patented design consists of two concentric pistons operated by a single diaphragm with one pressure chamber.
-
RT110 -
Klein Tools, Inc.
Light sequence indicates correct/incorrect wiring.Conforms to UL Std 1436, Certified to CSA Std C22.2 #160.Operating temp: 32°F to 140°F (0°C to 40°C).Built to withstand a 6.6 ft. (2m) drop.Nominal Voltage: 110/125V AC at 50/60Hz in 3-wire outlet.Designed to detect the most common wiring problems in standard receptacles.
-
CX-T04 -
Shenzhen Chuangxin Instruments Co., Ltd.
This Spring Impact hammer is strictly designed according to IEC60068-2-75, IEC884 and UL1244 GB/T2423.55-2006, GB4706.1, GB8898 and GB7000 standards. It is used to test the mechanical integrity of product enclosures. After applying the impact with the hammer, the product is examined with accessibility probes to determine access to shock, energy, and injury hazards. Built in exact accordance to IEC\EN, \UL\CSA and other international Standards.
-
PS401-HRP -
Axiomtek Co., Ltd.
*Input Range: 90 ~ 264Vac Full Range*Output Voltage:**+5V, 35A (5A min)**+3.3V, 28A (1A min)**+12V, 20A (2.5A min)**-12V, 1A**-5V, 0.8A**+5Vsb, 2A (0.1A min)*MTBF(hours): 100,000h*Safety: UL, TUV, CE, CSA*Dimensions: 183 x 167 x 187.8 mm*Compatible with Axiomtek products: AX61492
-
PS302-XP2 -
Axiomtek Co., Ltd.
*Input Range: 100 ~ 240VAC Full Range*Output Voltage:**+5V, 16A**+12V1, 17A**+12V2, 17A**-12V, 0.3A**+5Vsb, 2.5A**+3.3A, 19A*MTBF(hours): At 25°C, 100,000h*Safety: UL, CSA, CE, FCC*Dimensions: 150 x 140 x 86 mm*Compatible with Axiomtek products: AX61221, AX61222, AX61220, AX61400, AX6156LE, AX60552, AX60501,AX60551, AX61492
-
CX-12.5 -
Shenzhen Chuangxin Instruments Co., Ltd.
The rigid sphere (12.5 mm) from Autostrong is designed and manufactured to perform the test specified in many standards (IEC 60335, IEC 60065, IEC 60745, IEC 61029, IEC 60950) to prove the degree of protection for the first characteristic numerals 2 (IP2X) .Its is designed to meet the requirements of international safety regulatory agencies such as UL, DNV, IMQ, BVSQ, ITS, IRAM , CSA, VDE, DIN , INMETRO.
-
SSP-30XL -
Progressive Industries
Progressive Industries, Inc., a leading provider of Recreational Vehicle (RV) Surge & Electrical Protection products announces the debut of their new UL Listed (Underwriters Laboratory) & CSA Approved Portable Smart Surge Protectors SSP-50XL. Progressive Industries continues to raise the standard in RV protection innovation. The new Portable SSP-50XL’s offer impressive new features and several design features are “patent pending” for exclusivity of design and function.
-
Model InstaTrans-XD -
Teledyne Analytical Instruments
This model utilizes a design to meet the requirements of NEMA-4(IP-66) levels as well as ATEX Zone 0/1/2 and FM/FMc Class I Div 1 approvals when used with select intrinsic safety barriers. In addition, the CSA approval extends to Class I Div 2 as a non-incentive device without the use of barriers. The transmitter head contains the electronics and user display interface including 4-button design to access functions.
-
Ci3000+ -
Atlas Material Testing Technology
The Ci3000+ Weather-Ometer and Fade-Ometer with their advanced digital control systems, represent monumental achievements in applying digital and optical technologies in easy-to-use laboratory weathering instruments. The 3000 Series is approved by many OEMs in the textiles, paints & coatings and plastics industries as the exclusive platform to deliver accurate, reproducible and repeatable results for predicting service life. The 3000 Series has been certified CE, UL, CSA, ISO and EN compliant.
-
CX-Q03 -
Shenzhen Chuangxin Instruments Co., Ltd.
The Ball Pressure Apparatus is used to check the integrity of dielectric materials by exerting 20N force. The BPA10 is called out in IEC 60335, 60950, 61010, UL, CSA and European Norms. It is used to check the integrity of dielectric materials by exerting 20N force. The Ball Pressure Apparatus is made of stainless steel for long life. Since accelerated life procedures are used for this oven test, more than one apparatus may be useful for parallel testing.
-
Vision G2 Elite 8 -
Teledyne LABS
The Vision G2 Elite 8 dissolution tester is a versatile performance machine, built with the highest quality components and engineering. The G2 Elite 8’s ergonomic design and workhorse performance make it ideal for automation and extended applications as well as for 8-sample manual testing. The G2 Elite 8 meets and exceeds worldwide standards including compliance with USP, US FDA, ASTM, EP, JP, CE, CSA, RoHS, and 21 CFR Part 11.
-
PS270-1U -
Axiomtek Co., Ltd.
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 18A (0.5A min)**+3.3V, 16A (0.5A min)**+12V1, 16A (1A min)**+12V2, 10A (1A min)**-12V, 0.8A**+5Vsb, 2.5A*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CSA 22.2 NO.60950-1, IEC, UL, NEMKO, CE*Dimensions: 150 x 81.5 x 40.5 mm*Compatible with Axiomtek products: AX61120 / AX60530
-
BTK2 -
Dwyer Instruments Inc.
he Model BTK2 Backflow Prevention Test Kit is capable of testing hydronic systems with test procedures recommended by ASSE, AWWA, CSA, FCCC, HR-USV, and NEWWA. The BTK2 is comprised of three valves and is specially designed for testing backflow prevention assemblies. The tests can be completed in almost any area by mounting the unit with the included high performance elastic cord. PTFE-lined brass ball valves simplify the adjustment procedure. The large, easy-to-grip needle valve allows for quick adjustment.
-
Vision G2 Classic 6 -
Teledyne LABS
The Vision G2 Classic 6 dissolution tester is the compact, rugged workhorse sibling to the Vision G2 Elite 8. Named in honor of the world’s first dissolution tester, a six-position test station introduced by Hanson Research in 1969, the G2 Classic 6 is precision engineered to ease the rigors of manual dissolution testing. The G2 Classic 6 meets and exceeds worldwide standards including compliance with USP, FDA, ASTM, EP, JP, CE, CSA, RoHS, and 21 CFR Part 11.
-
Models M100BVS5 & M500BVS5 -
Rod-L Electronics
Now you can perform safe, rapid and efficient hipot testing, ground continuity testing, and total or real current monitoring in one simple operation. The ROD-L Electronics model M100BVS5 and model M500BVS5 hipot testers perform safe and accurate AC hipot and ground continuity testing in compliance with UL, IEC, CSA, VDE, FCC and other electrical equipment testing standards