Filter Results By:

Products

Applications

Manufacturers

Immunity Test

EMI exposure impermeability test.

See Also: Immunity, Radiated Immunity, Conducted Immunity, Radiated Emissions


Showing results: 121 - 135 of 139 items found.

  • Test Compliance

    CTS Series 3.2 - AMETEK Programmable Power, Inc.

    The CTS Series is a complete, turn-key compliance test system for EN IEC 1000-3-2 (Harmonics) Including A14, EN IEC 1000-3-3 (Flicker) and various EN IEC 1000-4 AC immunity tests. Consisting of an AC power source, a power analysis conditioning system (PACS) and a PC based data acquisition system, the CTS provides a complete turn-key solution for IEC testing. The Windows™ based CTS software performs the IEC tests and generates detailed test reports. Comprehensive data files are stored on disk to allow post test analysis.

  • Amplified Noise Modules

    NC1000 Series - Noisecom

    The NC1000 Series amplified noise modules produce AWGN as high as +13 dBm, and have bandwidths up to 10 GHz. The high power modules are designed to test noise immunity for Cable TV equipment, secure communication channels, and military jamming systems. The lower power modules, <= 0 dBm, are random jitter sources for many applications including, PCIexpress, Infiniband, and 10 GigE.

  • E-Series Average Power Sensor

    E9304A - Keysight Technologies

    Refer to the E9301A for standard power sensor features Low frequency coverage (9 kHz to 6 GHz) for EMC/EMI test applications such as the radiated immunity test (IEC61000-4-3)High sensitivity (-60 to +20 dBm) and fast measurement speed to reduce the time taken to calibrate radiated field uniformity and EMC/EMI test receivers Measure transmitter power and receiver sensitivity at Very Low Frequency (VLF) to microwave frequencies Special option available to 18 GHz Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters

  • RF Conducted Immunity Testing

    AR RF/Microwave Instrumentation

    If you are tired of mixing and matching various components, try AR’s complete line of RF Conducted Immunity Test Systems. We now make one fully configured and standalone CI System from 4 kHz to 400 MHz with output powers designed to meet the latest commercial, custom, and military standards. In addition, AR provides configurable systems meeting your specific requirements of increased power and frequency range.

  • Test Compliance

    MX CTS Series - AMETEK Programmable Power, Inc.

    A growing number of electronic products manufactured today have to meet international regulatory requirements for emissions and immunity. This is particularly true for products sold in the European community as well as a growing list of countries in the Far East. The California Instruments MXCTS System provides a cost-effective test solution aimed at verifying higher power product compliance to a number of AC and DC related harmonized test standards. The MXCTS system offers many of the same features and capabilities of the California Instruments CTS Series product line already in use at many EMC labs around the world.

  • One Port Vector Network Analyser

    TE3001 - TrewMac Systems Pty Ltd

    The TE3001 One Port Vector Network Analyser is built for the professional who understands the calibration process and has a network analysis task to perform. The unit features a larger output signal than the TE3000 for better noise immunity, and is supplied with a 6 piece custom calibration kit to remove the effect of test fixtures and cables. Together, these features make the TE3001 ideal for broadcast and plasma applications that require a length of cable for connection and may be high in noise or interference.

  • Biconical Antennas

    A.H.Systems, Inc.

    For many years most standards called for the use of a half-wave dipole antenna set for frequencies above 80 MHz. However, to reduce test time, broadband antennas such as the biconical antenna and log periodic antennas began to be accepted. Broadband antennas, compared to half wave dipoles, reduce test time because the technician did not have to stop the test to adjust the dipole antenna for each frequency. A.H. Systems'' 7 models of Biconical Antennas operate efficiently over the frequency range of 20 MHz to 18 GHz. Suitable for FCC, MIL-STD, VDE, TEMPEST, and immunity testing, each Biconical antenna will provide reliable, repeatable measurements.

  • LETIS

    Laplace Instruments Ltd.

    Power amplifiers that are universally used for radiated immunity testing either cover the range below 1GHz or the range above 1GHz. This means that if the test requirement extends both sides of this 1GHz point, the power amplifier needs to be changed over. Genrally, this involves three connections... The LETIS handles all these connections automatically. Each is switched via a high performance RF relay under the control of a USB interface. Software issued with the Laplace Synthesisers automatically detects the presence of a LETIS and handles the switching automatically.

  • Low-Noise DC Bias

    Pulse Instruments

    Imaging devices, such as CCDs, IR FPAs, and CMOS image sensors, require DC bias with very low electrical noise to prevent contamination of the image. Image quality can also be enhanced by carefully tuning each bias voltage to extract the maximum signal/noise ratio out of an array. Pulse Instruments has decades of experience providing DC bias supplies with the flexibility required tocharacterize and test a variety of devices while maintaining the noise immunity required for satellite and astronomy applications.

  • H.V. Multifuntion Phasing Sticks

    PC7k, PC11k, PC22k, PC33k, PC44k - Standard Electric Works Co., Ltd

    ● No user’s assembled parts.● Dual color-coded scale (%, Vac).● Neon indicator when >1200Vac.● Lightweight, robust & compact.● Carry case included.● Compare between phases.● Measure and test phase to earth.● High quality fiberglass wound rod.● Self powered operation. No battery required.● DC version available.● Measure phase to phase.● Hi immunity to interference fields.● Suitable for indoor and outdoor use.● Current is limited to ±1 milli-ampere.● Grounded or ungrounded systems.● Meets IEC 61481 (excludes PC44K).

  • Immunity Testing Systems

    CIS Series - Com-Power Corporation

    The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes an ACS series power amplifier, coupling/decoupling Network (CDN), directional coupler, 150Ω to 50Ω adapters, power attenuators, cables and [optional] CSAT software. These systems, when properly configured, are capable of testing your products to all levels given in IEC 61000-4-6 up to 230 MHz. You can choose from three systems. Follow the links below for detailed information, including a comprehensive datasheet listing system specs.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-01 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-02 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    781210-01 - NI

    Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.

  • Traveling Wave Tube Test System

    Yelo Ltd.

    Yelo has a wealth of experience in developing and customizing test systems for the Travelling Wave Tube (TWT) market. TWT testers feature specialized power supplies, measurement equipment, and comprehensive control and safety systems.A rugged PLC is used to control all voltages and perform all monitoring functions. User interface and datalogging functions are provided by a supervisory PC that is electrically isolated from the PLC. Power Supplies are solid state with optical fibre barriers to ensure that all control/monitoring is carried out at safe voltages, and with maximum noise immunity. All safety interlocks are hardwired, and the testers are equipped with emergency shutdown features for added security.

Get Help