Filter Results By:

Products

Applications

Manufacturers

LCD

Analyze Liquid Crystal Displays.


Showing results: 916 - 930 of 1292 items found.

  • High Temperature IR Thermometer - 50:1 Wide range InfraRed Thermometer with Laser Pointer

    Extech 42545 - Extech Instruments Corporation

    The 42545 is a High Temperature IR Thermometer which measures up to 1832°F (-50 to 1000°C) with 50:1 distance to target ratio and laser pointer that identifies target area. High 50:1 distance to target ratio measures smaller surface areas at greater distances for safe and accurate readings. Large backlit LCD display. Adjustable emissivity. Complete with 9V battery and carrying case.

  • LCR-Reader-MPA: Ultimate All-in-One Digital Multimeter

    Siborg Systems Inc

    LCR-Reader-MPA combines tweezer probes with a powerful LCR/ESR-meter that is able to determine the type of component and best test parameters before measuring with a 0.1% basic accuracy. The device will display the main impedance value, any secondary values such as ESR, Q or D, component type and test parameters used instantly on a bright backlit LCD display. The 1 oz. device is very portable and ideal for fieldwork.

  • Pan & Tilt Push Cameras

    Advanced Inspection Technologies Inc.

    Pan & Tilt Push Cameras Inspection System are the first true high definition push rod camera system with a remotely controlled pan & tilt camera. A brilliant 7" touchscreen LCD allows you to remotely control camera direction, focus add text annotation, view camera position and level. Super portable and operates on AC or DC power (4 hour rechargeable Li-ion battery).

  • AC/DC Clamp Meter

    3902 CL - Standard Electric Works Co., Ltd

    ● 2000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.

  • AC/DC Clamp Meter

    3904 CL - Standard Electric Works Co., Ltd

    ● 4000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.

  • AC/DC Clamp Meter

    3801 CL - Standard Electric Works Co., Ltd

    ● Full auto range for V.A and Ω functions.● LCD backlight display.● Flashlight function.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.

  • Video Signal Generator

    MSPG-3233RS - Master Co. LTD

    Analog was a main item in display device industries at the past time, but from now on, the digital is getting developed with multi-function and large-sized resolution. Preparing for this change, this signal generator is an essential equipment of CRT, LCD, PDP, TV, D-TV display device industries, which was made for generating analog signal, digital signal, and TV signal, D-TV signal, HDCP Code simultaneously and sufficiently examining a large-sized display device.

  • Digital Circuit Breaker Analyzer

    CT-3500 S2 - Manta Test Systems

    The CT-3500 S2 is Vanguard’s second generation, stand-alone, digital, microprocessor-controlled, circuit-breaker timer. It measures the elapsed time from the instant a breaker coil is energized to the instant of opening or closing of a circuit-breaker’s dry contacts. In addition to timing a breaker’s contact response time, the CT-3500 S2 can also time relays or other switching functions that use an initiating trigger voltage (24-300 Volts DC or AC). The timer-triggering voltage starts three independent electronic timers. Each timer is individually stopped by its respective dry-contact closing or opening. The CT-3500 can fully analyze the timing of all circuit breaker operations (Open, Close, Open – Close, and Close – Open). Timing results are displayed in milli-seconds and cycles on the unit’s back-lit LCD screen and can be printed on the built-in 2.5-inch wide thermal printer.

  • General Purpose Geiger Counter

    Radalert® 100X - International Medcom

    The Radalert® 100X is a general purpose geiger counter that measures alpha, beta, gamma, and X-radiation. Features of the Radalert® 100X, include a three-second update and a Utility Menu that allows you to change the default settings for several operating parameters. Its digital liquid crystal display (LCD) shows the current radiation level in your choice of SI units (microsieverts per hour) from .000 to 1,100 and counts per minute (CPM) from 0 to 350,000 or counts per second (CPS) from 0 to 3,500. For users of conventional units mR/hr (milliroentgens per hour) from .000 to 110 and CPM are optional in the Utility Menu. This instrument also offers an accumulated total and timer function, up to 9,999,000 counts and 40 hours.

  • Sound Level Meters

    Dalian Taijia Technology Co.,Ltd

    Display: 10mm (0.4″) LCD (Liquid Crystal Display)● Function: LP , Leq ,LN.● Frequency range: 31.5Hz~8kHz● Measurement range: LP:30~130dB (A) 35~130dB (C) 35~130 dB (F) Leq :30-130dB LN .: 0-100%● Resolution: 0.1 dB● Accarcy:1dB● Memory: Maximum value (30groups)● Indicator: Low battery indicator● Alarm: electron● Connector:RS232C● Power supply: 4x1.5v AAA (UM-4 battery● Size: 236 x 63 x26 mm● Weight: 170g (including batteries)● Standed delivery:1.Main Unit................1pc2.Carrying Case............1pc.3.Operation Manual.........1pc.● Optional Accessories:1.ND9 sound level meter calibrator2.RS-232 and software3.External rela4.Bluetooth interface

  • Temporal Artery Thermometers

    Shenzhen Everbest Machinery Industry Co.,Ltd.

    Body temp range: 30.0 to 43ºC/86ºF to 109ºFSurface temp range: 0 to 60ºC(32ºF to 140ºF)Basic accuracy: in mode of body +0.3ºC/+0.6ºFIn mode of surface +0.8ºC/+1.5ºFMeasuring distance: 5~15CMResponse time: 0.5 secondOver range indication: LCD will show "HI"/"Lo"Polarity Automatic (no indication for positive polarity)Minus (-) sign for negative polarityEmissivity: 0.95 fixed valueSpectral response: 6~14umPower off: automatic shut off after 7 secondsOperating temp.: 0ºC to 50ºC (32ºF to 122ºF)Storage temp. : -20ºC to 60ºC(-4ºF to 140ºF)Relative humidity: 10%~90% RH operating, <80% RH storagePower supply: 2X1.5V AAA batterySize (H x W x D): 131 x 82 x 35mmWeight: 130g

  • Oyster™ Series pH/mV/Temperature Meter

    Extech Oyster-10 - Extech Instruments Corporation

    Exclusive Oyster Design can be used in the lab or in the field. Large LCD built into adjustable “flip-up” cover displays pH or mV and Temperature simultaneously. Splash proof housing and front panel tactile touch pad to slope and calibrate. Rugged design for handheld or benchtop use; neckstrap for “hands-free” operation. Measures pH (0.00 to 14.00pH), mV (-999mV to 999mV) and Temperature (32.0°F to 212.0°F /0.0°C to 100.0°C). Accurate to 0.02pH, 2mV, 0.8°F/0.5°C and resolution of 0.01pH, 1mV and 0.1°. Memory function stores and recalls 25 labeled readings. Min/Max storage and recall, °C/°F switchable. Audible beeper to alert user when function is completed. Automatic or Manual temperature compensation. Probe sold separately.

  • Professional Thermal Camera

    FLIR T530 - Teledyne FLIR

    The FLIR T530 has the features professionals need to accurately troubleshoot hot spots and potential faults. With the 180° rotating lens platform and a bright 4" LCD, the FLIR T530 is engineered to help users diagnose hard-to-reach components in any environment. Advanced on-camera measurement tools, laser-assisted autofocus, and FLIR’s industry-leading image quality ensure you’ll find and diagnose problems quickly. With on-board Inspection Route mode, you can download and run survey plans to your camera from FLIR Thermal Studio Pro (with Route Creator plugin). Together these systems will help you record temperature data and imagery in a logical sequence for faster troubleshooting and repair. The purchase of a T530 camera includes a 3-month subscription to FLIR Thermal Studio Pro and FLIR Route Creator.

  • Milliohm Meter

    16502 - Chroma Systems Solutions, Inc.

    Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface

  • pHTestr® 5 Waterproof Pocket Testers

    OAKTON Instruments

    These pocket-sized testers have a replaceable single-junction sensor which can be easily switched out, allowing you to save money by using the tester body over and over again. A large LCD makes viewing measurements easy and features a three-color backlight indicating operational mode—blue for measurement, green for calibration and red for alarm condition. Additional features include hold function to lock in measurements, self-diagnostic error message, and status icons for measurement stability and low battery voltage. The IP67-rated housing features an easy-to-grip design and floats if accidentally dropped in water when sensor cap is on. Powered by four AAA batteries, the testers can operate up to 400 hours continuously. To conserve power, the unit will auto power-off after 8 minutes of nonuse.

Get Help