Filter Results By:

Products

Applications

Manufacturers

LCD

Analyze Liquid Crystal Displays.


Showing results: 1216 - 1230 of 1292 items found.

  • Digital Melting Point Apparatus

    DRK8011 - Shandong Drick Instruments Co., Ltd.

    DRK8011 Digital melting point apparatus is fully in line with ‘humanize’ of the design concept, using photoelectric automatic detection, dot matrix image LCD technology, digital keyboard input, each measuring one sample, measure three times the average of the melting point of the automatic strike, and has a melting, melting end automatically, melting curve automatic recording function. Temperature system uses high inearity make platinum resistance sensing element, the use of PID regulationtechnology to improve theaccuracy and reliability of the melting point, and with integrated electronic circuits to achieve rapid "starting temperature" setting and eight stalls to choose from linear "heating rate" Automatic Control. Instrument to establish communication with the PC via USB, save or print the graph, the instrument can be directly connected with the RS232 mini-printers, print graphs. The instrument uses Pharmacopoeia as a sample capillary tube.

  • Three-Channel Version of Rapidox 3100

    Rapidox 3100 OEM-3 - Cambridge Sensotec Ltd

    The Rapidox 3100 OEM-3 is a three-channel version of our high-performance zirconia oxygen (O2) analyser. Supplied in a metal controller box, the Rapidox 3100 OEM-3 comprises three individual zirconia sensors on bespoke length cables with several options for gas fittings. All three sensor channels are controlled by a single RS485 digital communications link to a PC or PLC using a high-speed USB EasySync device which is included as standard. A special version of our Rapidox software is provided giving full LCD emulation and datalogging of all three channels simultaneously. In addition, a full set of analogue outputs and alarms are provided for each separate channel for more traditional communications needs. We offer a bespoke scope of supply service for customers, which gives a flexible, seamless and cost-effective integration into machinery, products or processes. Please ask us about this service.

  • Benchtop Unit for Universal Coating Thickness Measurement

    FISCHERSCOPE MMS PC2 - Helmut Fischer AG

    Coating thickness measurement and material testing with just one instrument!Compact and extremely versatile desktop multi-function measuring system with data archiving and measurement data processing capabilities.User-friendly operation with large, high-resolution color LCD touch screen. Windows CE based.Many different plug-in testing modules allow numerous instrument configurations to meet the needs of the user. The modular design allows the upgrading of the instrument at any time. Similar or different modules can be installed depending on the applications.Different physical measurement principles are applied by the plug-in modules BETASCOPE, SIGMASCOPE, PHASCOPE, DUPLEX, NICKELSCOPE, SR-SCOPE and PERMASCOPE, Details see brochure.Multi-channel measurements at up to 8 measurement locationsA great variety of probes for different test piece geometries and measuring ranges are available.Delivery with PC software FISCHER DataCenter with the following functionality: Transferring and archiving measurement data, comprehensive statistical and graphical evaluations, easy creation and printing of inspection reports

  • Electronic Ballast Automatic Test Equipment

    ATE-1 - Lisun Electronics Inc.

    Test series connection, parallel connection and series/parallel connections of the electronic ballast (about 15 kinds of connections), available for various electronic ballast. • With a precise resistance box, tube is substituted for the resistance, can act as many as 6 tubes. Resistance value: 1-4095Ω adjustable. • Measure input parameters (vrms, irms, w, pf, harmonics, etc), output parameters (on-circuit voltage, lamp voltage, filament voltage, lamp current, lamp power, oscillatory frequency), can also test the ballast efficiency, abnormity protection, and power symmetry of partial rectifier effect and etc. • Program controlled AC power source to guarantee the smart choice of input voltage and the frequency. • Equipped with 17 inch LCD controlled machine, specially designed A/D combined with special CPU, has the two left and right testing interfaces to achieve stability of data and high- speed testing. • We can make the special-designed product for you and promise to upgrade the software for free.

  • Handheld Water Quality Meters

    LAQUA PH210 - HORIBA, Ltd.

    - Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers) - 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty

  • Handheld Water Quality Meters

    LAQUA EC210 - HORIBA, Ltd.

    - Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Automatic / manual temperature compensation and temperature calibration function- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data - Auto stable, auto hold, and real-time measurement modes- Auto shut-off (programmable: up to 30 minutes)- Monochrome LCD with white LED backlight: 50 x 50 mm- Powered by 2 x AA batteries - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty

  • Handheld Water Quality Meters

    LAQUA DO220 - HORIBA, Ltd.

    Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation0.01 mg/L or 0.1% DO resolutionCompensates salinity, temperature, and atmospheric pressure Allows up to 2 calibration points using galvanic DO electrode°C & °F temperature readingsWith real-time clock and date/time stamp for GLP complianceAuto log data; built-in memory can store up to 1000 dataAuto stable, auto hold, and real-time measurement modesAuto shut-off (programmable: up to 30 minutes)Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mmPhono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slipPowered by 2 x AA batteriesPackaged with galvanic electrode in carrying case3 years meter warranty

  • Laser Diode Driver

    S-101 - Notice

    LD Driver slot module of FOTS system is an efficient module that is user centered, which can drive various kinds of laser diode for the use of optical signal transmission or light source. The module has a built in LD socket, in which LD of 14 pin butterfly type is installed, which makes it possible for the user to change the LD he or she wants to drive when needed. It is leaded to get rid of the inefficiency of expense, at which various types of expensive united source module needed are purchased. By operating monitoring PD and high-performance processor that are installed inside the module, the output power and temperature of LD can be driven accurately and stably. The laser diodes can be modulated internally in square, sinusoidal, and triangular waves and its output power and temperature can also be maintained the level set by the user. In order to realize the various functions, the efficient and multi-functioned control programs with high speed processor, LCD monitor or GUI for remote control are available.

  • Surveyor Thickness Gauge

    Multigauge 5650 - Tritex

    The Multigauge 5650 Surveyor Thickness Gauge is a simple, robust ultrasonic thickness gauge designed specifically for ship and small craft surveyors, but can also be used in applications where different measurement modes are required. The user has a choice of Multiple Echo, Echo to Echo or Single Echo to cover all requirements. The gauge can be used for metal, GRP or plastic measurement and it automatically switches modes and settings depending on the type of probe fitted. The easy to use keypad on the Surveyor Thickness Gauge allows operator interface whilst the bright LCD display can be used in all light conditions. All probes have Intelligent Probe Recognition (IPR), which automatically adjusts settings in the gauge at the same time as transmitting recognition data the result is a perfectly matched probe and gauge for enhanced performance. Additionally, the Automatic Measurement Verification System (AMVS) used with multiple echo ensures only true measurements are displayed, even on the most heavily corroded metals.

  • Lab Oven

    ACE Technology

    Provided to industrial and mining enterprises, laboratories and scientific research for desiccation, torrefaction, wax-melting and sterilization. Features 1.Microprocessor control (with timing function) 2.Interior of oven is made of secular steel by argon-arc-welding techniques, and the exterior of oven is made of high-quality steel sheet with a beautiful and novel appearance. 3.Microprocessor PID temperature controller with temperature control protection, digits display and timing function ensures a precise and reliable temperature control. (Intelligent programmable LCD temperature controller is and option). 4.Hot-air circulating system consists of a fan keeping running under a high temperature and proper air ducts to ensure a uniform distribution of temperature in chamber. 5.Independent alarm system for temperature-limiting ensures experiments run safely and no accident would happen. (Option) 6.Recorder and printer are options which can print or record setting parameters and tracing variation curves of temperature. (Option)

  • Digital Colorimeter & Illuminance Meter

    CHC-I - Lisun Electronics Inc.

    This Digital Color Meter & Illuminance Meter is based on all digital integral photometric and colorimetric measurement technology. It has no analogue unit, thus it is very simple to overcome the zero drift which is impossible to be avoided in current colorimeter. The digital X (λ), Y (λ), Z (λ) sensor has large dynamic range so that there is no range-changing error in it; moreover, it possesses strong anti-interference ability and high accuracy. The CHC-I contains internal RS232 computer interface, the calibration is done by software. It is suitable for monitoring and remote applications. The CHC-I software can calibrate the instrumentation, sample the data through RS232 interface and print out the results. It can also be calibrated by other standard light sources to obtain very high measuring accuracy of x, y color coordinate and color temperature. It is a real-time measuring system and run under Windows System. 128*64 lattice LCD display, RS232 computer interface and software, Data hold function.

  • 5KVA to 100KVA Industrial UPS (3Ø – 1Ø)

    NSP Series 5KVA to 100KVA - Aplab Limited

    - Designed for powering critical Industrial and IT systems- DSP controlled IGBT based PWM technology- Design topology enables N+1 parallel redundancy- Industrial grade high speed CAN bus communication- User Friendly Matrix LCD and LED mimic front control and digital monitoring- Fully rated make before break maintenance bypass operation- Optional break-less load transfer via static switch- Low harmonic distortion- High crest factor tolerance and dynamic stability- Lower TCO- Continuous full rated power at ambient as high as 45°C- N+1 Parallel operation of UPS without any common hardware- Advanced Communication Capability (RS485/Modbus/SNMP)- High branch fuse clearing capacity- On-line battery bank test without load disconnection- Compact, elegant, and light weight enclosure- Easy installation with wheels for maneuverability and front bottom terminals

  • 20KVA to 200KVA Industrial UPS (3Ø – 3Ø)

    NSP Series 20KVA to 200KVA - Aplab Limited

    - Designed for powering critical Industrial and IT systems- DSP controlled IGBT based PWM technology- Design topology enables N+1 parallel redundancy- Industrial grade high speed CAN bus communication- User Friendly Matrix LCD and LED mimic front control and digital monitoring- Fully rated make before break maintenance bypass operation- Optional break-less load transfer via static switch- Low harmonic distortion- High crest factor tolerance and dynamic stability- Lower TCO- Continuous full rated power at ambient as high as 45°C- N+1 Parallel operation of UPS without any common hardware- Advanced Communication Capability (RS485/Modbus/SNMP)- High branch fuse clearing capacity- On-line battery bank test without load disconnection- Compact, elegant, and light weight enclosure- Easy installation with wheels for maneuverability and front bottom terminals

  • Hazardous Location Syringe Pump

    100HLf - Teledyne LABS

    Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compat​ible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Hazardous Location Syringe Pump

    1000HLf - Teledyne LABS

    The Teledyne ISCO HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

Get Help