Showing results: 31 - 45 of 63 items found.
-
Inframet
Meters offered by Inframet are basically meters designed to support calibration of test systems manufactured by Inframet. The meters can be divided into two groups:*Temperature meters*Luminance meters
-
SphereOptics GmbH
Imaging colorimeters and photometers of the ProMetric® series are calibrated to replicate human response to brightness, color, and scatter. The ProMetric® Imaging colorimeters and photometers are cooled CCD-based camera systems designed to make precise, spatial measurements of luminance and chromaticity.The spatial measurement capabilities are luminance cd/m², radiance W/m², illuminance lux, irradiance W/m², luminous intensity candela, CIE chromaticity coordinates, L*a*b color scale, correlated color temperature, dominant wavelength.
-
SphereOptics GmbH
Versatile, miniaturised spectroradiometer with the ability to measure both spectral radiance (luminance in cd/m²) and spectral irradiance (illuminance in lux) in one instrumentSpecbos models provide for measurements in the 250-1000 nm range, with specialist versions available for flash photometry and average LED intensity in accordance with CIE 127:2007A built-in red laser pointing device conveniently defines the measurement spot for luminance measurementsThe large variety of accessories and the UV option make this small instrument to a versatile all-rounder to fit a lot of applications
-
HD2102.1 -
Delta OHM S.r.L.
Portable handheld luxmeter for measuring illuminance, luminance, PAR, irradiance (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve).
-
CHROMA-1 -
Lisun Electronics Inc.
• Measure Pa rameters: CCT, Chromaticity Coordinate(x, y, u, v) • Display range: 1500K~25000K, Resolution: 1K • Accuracy: 0.5%F.S. • Luminance test function (lx test)
-
MI-6201 Multinorm -
Metrel d.d.
Universal all-in-one instrument for measurement of air temperature, air velocity, relative humidity, illuminance, luminance and the Class 1 (Pro Set) or Class 2 (Euro Set and Standard Set) sounds analyses.
-
Spectra Cine, Inc.
The Spectra One degree Photospot is a unique optical accessory that converts your Spectra Professional IV-A into a high-sensitivity one degree Spotmeter for narrow-angle reflected-light measurements. Readings are displayed in reflected f/stop or in footlamberts in luminance mode
-
DTS Series -
Instrument Systems Optische Messtechnik GmbH
Characterization of emissive, transmissive, reflective, and transflective displaysViewing-angle-dependent analysis of illuminance, contrast, color, and derived parametersDetermination of the electro-optical transfer function: analysis of luminance, contrast, and color depending on electrical driving conditionsMeasurement of transient properties, such as switching times, flicker, and modulation
-
MS-321LR -
EKO Instruments Co., Ltd.
The automatic Sky Scanner MS-321LR is designed only to measure Luminance and Radiance of the sky hemisphere. The sensor has 2 highly sensitive detectors which respond to the low light levels of the diffuse sky and will automatically block direct radiation by the active shutter function.
-
Radiant Vision Systems, llc
Calibrated to replicate human photopic response to brightness and color, Radiant ProMetric® Imaging Colorimeters and Photometers are scientific-grade camera systems designed to make precise, spatial measurements of luminance and chromaticity. These systems are used to design and qualify light-emitting elements and devices according to how they will be visually experienced by human users.
-
Model 7123 -
Chroma ATE Inc.
Luminance and chromaticity measurement of Color Display0.005 cd/m2low luminance measurement (A712301)Wide luminance range: 0.0001 to 25,000 cd/m2 (A712301) 0.01 to 200,000 cd/m2 (A712302)High accuracy measurementMaximum 9 display modes: xyY, TΔuvY, u’ v’ Y, RGB, XYZ, Contrast, ProgramAble to control Video Pattern Generator and UUT (Unit Under Test)Built-in contrast measurement function to calculate the contrast ratio directlyEquipped with programmable test items that can complete the planned tests with one single buttonSupport USB flash disk that can copy the test procedures to other station for useJudgment function embedded to judge the test result automatically with one single buttonCalibration period setting and reminding functionMemory for storing 100 channels of standard color data and calibration dataBuilt-in flat display calibration data LCD-D65 & LED-D65* to be applied for chromaticity measurement instantlyOptional display white balance alignment system can be used to integrate all optical test stations to one single station
-
Harkness Screens International Ltd
The low-cost digital cinema luminance meter for accurately measuring screen brightness. Now available, the Digital Screen Checker is an ideal tool for projection managers / projectionists or service engineers to monitor screen brightness and check lamp life. The Digital Screen Checker from Harkness Screens helps exhibitors to ensure that their presentations remain at optimum levels and ensure DCI-compliancy.
-
MCH Instruments Co.,Ltd.
Is a measurement apparatus capable of visually depicting regular changes in electrical activity, such as an electrical current or signal. The resulting data appears as a waveform drawn on a graph with two axes, where the horizontal X axis represents time and the vertical Y axis indicates voltage. In addition, the luminance of the waveform itself is often referred to as the Z axis, which demonstrates the intensity of the activity measured.
-
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.
-
Gamma Scientific Inc.
Lamp-based calibration light sources from Gamma Scientific are used for optical calibration of light measurement instruments including spectroradiometers, photometers and radiometers. All of our calibration light sources meet rigid quality standards for use in the most challenging testing environments. A wide range of light sources is available to serve as precision standards of radiant flux and white-light standards of spectral irradiance or luminance.