Filter Results By:
Products
Applications
Manufacturers
-
product
Laser & LED Testing
Lasermet is the UK’s leading test house for testing to the following standards:EN 60825-1 / IEC 60825-1*EN 60825-2 / IEC 60825-2EN 60825-12 / IEC 60825-12*EN 60601-2-22 / IEC 60601-2-22*21 CFR 1040.10and is the only test house with UKAS accreditation for laser and LED testing (other than the National Physical Laboratories).
-
product
Immunity
EFT coupling
s used for direct-contact measurements of impulse immunity in IC pins, according to IEC 62215-3 and IEC 61000-4-4.
-
product
Temperature Logger For Human Body Range
HBTS 2.0
The HBTS is designed to monitor the temperature of parts, gas or liquids associated with intended/unintended heat to the patient. High accuracy and resolution is achieved in a range of 0-75°C. Typical standards are IEC 60601-1 (Table 24), IEC 60601-2-18 (endoscopes), IEC 60601-2-19 (infant incubators), IEC 60601-2-21 (radiant warmers), ISO 80601-2-74 (humidifiers).
-
product
Source Code Libraries
We provide ANSI 'C' source code libraries for IEC 61850, DNP3, IEC 60870, and Modbus that can easily be ported to your device.
-
product
Voltage and Current Measuring Technology
HIGHVOLT Prüftechnik Dresden GmbH
Designed for the measurement of alternating current (AC), direct current (DC), lightning (LI) and switching (SI) impulse high voltages (HV) as well as AC and impulse high current (HC) according to IEC 60060, IEC 61083 and IEC 60052, available as indoor and outdoor design.
-
product
Glow Wire Test Apparatus
GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.
-
product
Glow Wire Test Apparatus
GWT A2
GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.
-
product
Electronic Ballast Tester
WT5000
WT5000 is the updated version of WT3000 with a super LCD for displaying waveforms and parameters directly, and it includes all the functions and technical parameters of WT3000. Reports can be printed if printer is connected. It also meets the latest requirements for electronic ballasts in international standards IEC 60929, IEC 60969, IEC 61000-3-2, GB/T15144-2005, GB/T17263-1998 and so on.
-
product
Current Transformer
DCT 57
Shanghai Powoo Industry Develop Group Limited
Accurate DC measurement, comply to IEC 1036 and IEC 62053. Suitable for a wide range of current (from 1.5A to 100A); linear output current, high precision; compact, delicate appearance.
-
product
DC Immune Current Transformer
DCT 108
Shanghai Powoo Industry Develop Group Limited
- Accurate DC measurement; comply to IEC 1036 and IEC 62053; - suitable for a wide range of current (from 1.5A to 100A); - linear output current, high precision; - compact, delicate appearance.
-
product
Electrical Testing Monitoring
The IEC 61850 represents the migration from the analog to the digital world to the substations. Accordingly, industry faces a period of transition, also noticing the effects of IEC 61850 in the traditional checking and monitoring procedures.
-
product
Thermometer / Cardiac / Invasiv, non Invasiv Blood Pressure Simulator
TBH-400
Test device for functional testing of medical thermometers (DIN EN ISO 80601-2-56), cardiac output, invasive (IEC 60601-2-34) and non-invasive blood pressure devices (IEC 60601-2-30).
-
product
Electrical Safety Tester
PSE AG has developed an electrical safety test that combines different tests for the testing of PV modules. With our four-in-one tester it is possible to test the following according to IEC 61215-2 and IEC 61730:
-
product
Socket Outlet Torque Test Device
CX-LJ
Shenzhen Chuangxin Instruments Co., Ltd.
*For measuring and testing the torque strain exerted by appliances with plug pins on socket-outlets, in accordance with IEC 60065 clause 15.4.1 and figure 11, IEC 60335-1 clause 22.3, IEC 60884-1 clause 14.23.2. *The balancing arm of the test apparatus pivots about a horizontal axis through the center lines of the contact tubes of the socket-outlet at a distance of 8 mm behind the engagement face of the socket-outlet.
-
product
Transient Over-voltages Tester
SUG335
The SUG335 is a 1.2/50μs Transient Over-voltages Tester. The polarity interval time can be at least 1s. The standard voltage waveform complies with the IEC 60335, IEC61180, IEC 62052-11: 2003, IEC 61008-1: 1996, IEC 61009-1:1996 and IEC 60947-1: 1995, IEC60060, IEC1036 surge voltage test and has been used for safety testing to determine if the clearance was fulfilled the safety requirement while the transient voltage in the circuit.
-
product
Socket-Outlet Torque Balance
CX-L12
Shenzhen Chuangxin Instruments Co., Ltd.
For measuring and testing the torque strain exerted by appliances with plug pins on socket-outlets in accordance with IEC 60065/1998-07 § 15.4.1 Fig. 11, IEC 60335-1 / 1991-04 § 22.3, IEC 60884-1 / 1994-06 § 14.23.2, EN 60335-1/1994 + A11 /1995 § 22.3, EN 60950/1992 + Amendments up to 1997-03 § 4.3.18, VDE 0700 Part 1 /1995-10 § 22.3, VDE 0805/1997-11 § 4.3.18
-
product
Immunity
RF coupling
is used for the conducted measurement of the immunity according to IEC 62132-4.
-
product
Power Gail Generators
Voltage dips, short interruptions or voltage fluctuations in the public supply networks can affect electronic and electrical equipment to a large extent. The AC-tests for this are defined in IEC / EN 61000-4-11 and the DC test in the IEC / EN 61000-4-29.
-
product
Sound Level Meters
Acoustic Data These definitions are intended simply as an aid to understanding and for this reason, some are not strictly scientifically accurate. For correct formal definitions, consult IEC standards 60651, 60804, 60942, 61252 and IEC 61672: 2003 part 1.
-
product
ESD - Simulator
SESD 216
The test generator SESD 216 simulates electrostatic discharge as defined in the standard IEC / EN 61000-4-2. Depend on the Equipment Under Test (EUT) and the test set-up for laboratory tests the IEC standard shows two test methods
-
product
ESD - Simulator
SESD 230
The test generator SESD 216 simulates electrostatic discharge as defined in the standard IEC / EN 61000-4-2. Depend on the Equipment Under Test (EUT) and the test set-up for laboratory tests the IEC standard shows two test methods
-
product
200W to 250W - Single Output
CUS200M Series
*IEC 60601-1 (2xMOPP), IEC 60950-1 Approvals*200W Convection Cooled Rating*High Efficiency, up to 94%*Industry Standard 3" x 5" footprint*Suitable for B and BF rated equipment*5V Standby Output
-
product
Protection Relay Test Generator
The MIG0603OS2 includes combination wave circuit IEC 61000-4-5. Additionally a 0.5J, 500 Ohm circuit is included in accordance with IEC 60255-5. The two BNC monitor outputs allow monitoring the voltage and current wave shapes by an oscilloscope
-
product
Conduit Bending Tester
King Design Industrial Co., Ltd.
Equipment complies with IEC 61730-2:2004 MST 33 specification.
-
product
IEC61032 Test Probe Pin
CX-112
Shenzhen Chuangxin Instruments Co., Ltd.
1. Jointed test finger probe (Figure 2 / Test Probe B / IEC 61032)This is a precision probe made in accordance with all IEC standards. Examples are IEC 61032, 60950, 61010 and 60601; and it is also used for Canadian and USA standards. It features a palm simulator and a restricted joint movement, which simulates the characteristics of the human hand. The finger is made of stainless steel and the rest of the instrument is Delrin®. Handle is designed to accept either a banana jack or a force gauge.It is no longer necessary to have a separate probe for the medical safety standard. This one probe will meet all the different requirements that are in the IEC standards.
-
product
Protection Relay Testing
Haomai Electric Power Automation Co.,Ltd.
1)Embedded industrial PC with 9.7" TFT LCD screen 2)Both online and offline test available 3)Can test both universal and IEC 61850 protection relay 4)6-phase current + 6-phase voltage output 5)Provide various type of messages which conforms to IEC 61850-9-1/9-2,GOOSE, IEC 60044-7/8 FT3 6)Able to test MU and optical digital signal 7)Built-in GPS module
-
product
Plug Socet & Cord Testing
Educated Design & Development, Inc.
Flexing Tests: On flexible cables (or cords sets with fitted plugs), electric tools or hand lamps. Meets requirements of standards such as IEC 60335, IEC 60227, IEC 60745 and UL745. This product is for continuous bending tests of cables or cord sets fitted with plugs. The model F39 allows the simultaneous testing of two samples in it's standard version. This not only allows for substantial time savings, but also allows for the testing current circuits to be simplified by looping through the cables.
-
product
4.0mm Hazardous Live Parts Probe
CX-A4D
Shenzhen Chuangxin Instruments Co., Ltd.
Used to verify protection against access to hazardous parts through top openings. Meets IEC, EN, UL and CSA Standards including IEC 1010, EN61010-1, UL3101-1, and CSA 1010-1. The handle and stop face are made of Delrin. The rod is made of stainless steel.
-
product
K Thermocouple Air Probe
TP744