Filter Results By:

Products

Applications

Manufacturers

IEC

International Electrotechnical Commission.

See Also: Standards, IEEE


Showing results: 316 - 330 of 586 items found.

  • Capacitor Tester

    MIG0603CAP - EMC Partner AG

    The MIG0603CAP consists of two circuits with impulse capacitance 20 µF and 0,25 µF. Both circuits generate a voltage wave shape 1,2/50 µs and are combined in a 4 unit height 19" rack. The generator circuits are defined in IEC 60384-14 and EN 132400. The serial resistors Rs, the impulse capacitor CT, and the load capacitance Cp will be automatically switched when different capacitance ranges are selected on the MIG0603CAP.

  • Pyranometer

    SR15-A1 - Hukseflux Thermal Sensors B.V.

    SR15-A1 is a high-accuracy solar radiation sensor. It is” First Class” according to the ISO 9060:1990 standard and “Spectrally Flat Class B” in the 2018 revision. With its on-board heater, it is compliant in its standard configuration with the requirements for “Class B” PV monitoring systems of the new IEC 61724-1:2017 standard. SR15-A1 measures the solar radiation received by a plane surface from a 180 o field of view angle.

  • Horizontal & Vertical Sphere Gap

    SGS H & SGS V - Shanghai Jiuzhi Electric Co., Ltd.

    The sphere gap type SGS H or SGS V can be used for Impulse, AC and DC voltage calibration according to the IEC 60052 recommendation.The spheres are arranged vertically or horizontally, one being mobile. In the vertical version the mobile sphere is remotely adjusted by using an electrical drive. In the horizontal version, both spheres are mounted on columns of insulating materials, hence enabling to superimpose impulse AC and DC voltages.

  • Ear Simulator

    BO1028 - BaKo Co., Ltd

    The BO1028 Ear Simulator is a special coupler for microspeakers or earbuds that has been designed to be compliant with ATU-T P.57 and IEC 60318-1. While mics in our BP1090 couplers receive sound waves the way they travel through air, the dual compartment chamber of the BO1028 is designed to modify sound pressure so that the mic receives air vibrations the way a human ear drum would receive them.

  • EtherCAT Workbench

    ESD Electronic System Design

    EtherCAT® is a very flexible real-time Industrial Ethernet protocol published as IEC 61158 standard. The data exchange follows the 'processing on the fly' principal which means that data is passed by each slave device with just a minimal delay before it is processed. This makes EtherCAT to the ideal solution for Ethernet based industrial control systems with many distributed I/Os and/or cycle times less than 100 µs.

  • MCB Temperature Rise and Power Loss Test Bench

    SCR ELEKTRONIKS

    The SCR Elektroniks 3 station MCB Temperature Rise and Power Loss Test Bench is economically designed to verify temperature rise and measure power loss as per clause 9.8 of IEC 60898 with the circuit designed to follow test procedure as per Cl 9.8.2. The temperature rise is measured in accordance with Cl 9.8.3 and 9.8.4 while power loss is measured and verified as per Table 15 of Cl 9.8.5.

  • Close Match Solar Simulators

    TS Space Systems

    We design and manufacture a wide range of world leading solar simulators that meet and surpass the IEC, ASTM and JIS international standards. Our close spectral match solar simulators are used across the globe in world-leading laboratories. Our award winning Unisim solar simulators are used in both research and development work as well as 24/7 production facilities and are regularly cited in the latest photovoltaic research literature.

  • Plastic Optical Fiber Analysis System

    2500 - Photon Kinetics

    While the 2500 Optical Fiber Analysis System is the industry-standard for testing standard, silica multimode optical fibers, it is also capable of performing comprehensive characterization of the new generation of graded-index plastic optical fibers (GIPOF). The 2500 provides high speed, repeatable measurement of several critical fiber properties including spectral attenuation, time- domain (pulse) bandwidth, single-mode launch differential mode delay, core diameter and numerical aperture - all in accordance with recently developed IEC measurement standards. The GIPOF-capable 2500 is compatible with fibers having core diameters up to 120 um (IEC Type A4g and A4h).

  • Product Safety and Compliance Testing

    Washington Laboratories LTD.

    We provide Testing and evaluation to IEC 60950, 61010, 60601-1 for information technology, industrial, laboratory, measurement and medical equipment. We also provide NRTL support for product safety certification and listing to OSHA Nationally Recognized Testing Laboratory program.

  • Full-Featured Life Cycle Test System

    LCV - Bitrode, Inc.

    Configurations for testing to industry standards: IEC, SAE, BCILife Cycle Testing: Perform charge/discharge cycling of batteries or modules to obtain charge and discharge capacity, energy and DC internal resistanceAutomotive Battery TestingStarting, Lighting and Ignition (SLI) TestingTraction Battery Testing

  • GNSS Satellite Clock

    TTM 01-G - Tekron International Ltd

    The TTM 01-G is a reliable and accurate GPS and GLONASS (GNSS) clock with sub-microsecond timing that is used to synchronize IEDs (Intelligent Electronic Devices) in the power industry and other industries where precise and reliable timing is required. As with all Tekron GPS clocks, the TTM 01-G has electrically isolated outputs, providing excellent noise immunity. The TTM 01-G supports both NTP/SNTP (IEC 61850) and PTP (IEEE 1588 v2).

  • Bore Gauges Xtreme 3 Holematic Smart

    Sylvac

    • Great measuring range (2 - 300 mm)• Bluetooth® and Proximity• Blind bore measurement from 2 to 6 mm and from 12.5 mm• Fixed anvils• UKAS certificate included with all rings• UKAS certificate included with each instrument• Manufactured according to DIN863• Memorization of 4 ring gauges values• Water and coolant resistant, protection rating IP67 according to IEC 60529• Programmable by PC

  • Capacitive Discharge Testers

    Compliance West USA, Inc

    For IEC Testing of residual voltage after plug disconnect. The CDT-240 disconnects the line at the voltage peak and analyzes results to the requirements of various Standards, allowing quick results. Scope output for viewing decay waveform. Presets for EN 61010, EN 60065, EN 60950, EN 60601-1 and EN60335. Recommendations for Pluggable Type B equipment. NIST calibration supplied; A2LA calibration available. 16A option for testing large equipment.

  • Powerline Analyzer

    SHARK 100 - Amperis sl

    Amperis introduces one of the highest performance panel-type billing grade meters in the industry. Based on a new platform, this low cost meter significantly outperforms other much more expensive equipment. This unit is perfect for new measurement applications and for direct and simple replacement of existing analog meters. The Shark is excellent for high accuracy energy measurement exceeding ANSI C12.20 (0.2%) and IEC 687 (0.2%) energy measurement standards.

  • External Micrometers

    Rhopoint Metrology Ltd

    Automatic wake-up by moving the measuring spindleSleep mode after 20 min. of no usePosition memorised in sleep modeWater protected for heavy-duty work with coolants and lubricants, protection rating IP67 according to IEC 60529, with or without connectorMeasuring range 0-102mm covered with 3 instruments onlySet of 3 micrometers 0-102mm availableQuick displacement of the measuring spindle 12mm / rotationBattery life 12,000 hoursNon-rotating spindlePreset functionSetting masters provided where applicable

Get Help