Showing results: 436 - 450 of 581 items found.
-
PSE Instruments GmbH
The potential induced degradation (PID) is addressed with the standard IEC TS 62804-1. The standard defines two methods that enable analyzing occurring PID effects in a specific PV module type. PSE AG offers the necessary equipment for the test in a climate chamber. The test equipment can work with any climate chamber on the market and is delivered turnkey. It comes with all necessary equipment, high voltage power sources, sensors, data acquisition and software.
-
Extech 407732 -
Extech Instruments Corporation
This type 2 sound level meter meets ANSI and IEC 651 Type 2 standards. Ideal for noise surveys in the workplace, installing fire alarms and speaker systems and enforcing noise ordinances. Measures from 35 to 130dB in 2-ranges with accuracy of plus or minus 1.5dB. Data hold and Max hold functions. Backlit display allows use in dimly lit areas. Complete with microphone wind screen and 9V battery.
-
Extech 407760 -
Extech Instruments Corporation
407760 Sound Level Datalogger can record up to 129,920 records and uses a USB interface for easy setup and data download. The datalogger meets ANSI and IEC 61672 Class 2 standards with a 1.4dB accuracy. Additional features include A and C weighting, Fast/Slow response time, and 2 start methods: programmed (from PC) or manual. Comes complete with software, tripod, USB extension cable, windscreen, and 3.6-Volt Lithium battery.
-
VET-1608 -
Veer Electronics
VEER make Digital Epstein Tester VET-1608 is complete stand alone instrument to measure AC magnetic properties of electrical steel of all grade and gauges mostly. It refers ASTM-343 standard. It also refers IEC 60404-2 & IS:649. Epstein Frame method is standard & worldwide accepted method to test important magnetic parameters like Watt/kg, VA/kg, Magnetizing Force, Permeability, Form Factor etc on different induction.
-
MIG2412SPD -
EMC Partner AG
The MIG2412SPD is a impulse tester for testing SPD (Surge Protection Devices) in accordance with IEC 61643-1 and VDE 0675. Up to maximum 24kV/12kA making it suitable for testing Class I to III or in accordance with VDE Class A,C, D. The MIG2412SPD is a hybrid generator with a voltage wave shape 1,2/50 ìs at "no load" and a current wave form 8/20 ìs at short circuit for testing Class III (D) SPD connected to power line.
-
Castle Sonus GA216I -
Castle Group Ltd.
The Castle Sonus GA216i is a feature packed instrument, fully compliant with IEC 61672:2002 Class 2. This meter gives simultaneous Leq and peak measurements for assessments to the Control of Noise at Work Regulations 2005. It has a high-specification measurement microphone and is cased in tough, crack resistant ABS plastic. To comply with the Control of Noise at Work Regulations 2005, this Class 2 Sound Level Meter enables you to assess Noise in the workplace at fantastic value.
-
SA 30i -
Scope T&M Pvt, Ltd.
SA 30i, the Leakage Current Analyser from SCOPE is a State of the Art, On-line test system for Residual Life Assessment of Metal Oxide Surge Arresters. The instrument measures and directly displays the values of Total Leakage Current and Third Harmonic Resistive Leakage Current. It provides system harmonic compensation as per IEC 60099-5-B2. It provides Corrected Resistive Leakage Current after applying correction factors for change in system voltage & temperature.
-
CX-Q03 -
Shenzhen Chuangxin Instruments Co., Ltd.
The Ball Pressure Apparatus is used to check the integrity of dielectric materials by exerting 20N force. The BPA10 is called out in IEC 60335, 60950, 61010, UL, CSA and European Norms. It is used to check the integrity of dielectric materials by exerting 20N force. The Ball Pressure Apparatus is made of stainless steel for long life. Since accelerated life procedures are used for this oven test, more than one apparatus may be useful for parallel testing.
-
W-IE-NE-R, Plein & Baus GmbH
VME is a high speed and high performance bus system with powerful interrupt management and multiprocessor capability. It was created by combining VERSA-bus electrical specifications (1979) with the Euro card format resulting in the VME-bus Revision A - 1981 specification. The VME-bus specification has since then been refined through revisions B (1982), C, C.1, IEC 821 & IEC297 and IEEE 1014-1987. VME represents one of today's most used industry bus .
-
LDS-6 -
Doble Engineering
The Doble LDS-6 is a highly sophisticated digital measuring system for partial discharge detection and analysis. It is trusted as a valuable tool for factory and laboratory testing.The LDS-6 can be used to test a variety of high voltage apparatus. Use the LDS-6 to perform PD quality tests on motors, generators, transformers, MV and HV cable systems, switchgear and additional HV accessories.The LDS-6 complies with IEC 60270, VDE 0434 as well as various IEEE and other standards.
-
Extech 407766 -
Extech Instruments Corporation
This 1kHz 94/114dB professional sound calibrator is for 0.5 in. or 1 in. microphones. Calibrates and verifies sound level meter operation. Level position switch to select 94dB or 114dB with power on LED indicator light. Durable die-cast aluminum housing generates a 1kHz sine wave at 94dB/114dB to an accuracy of 5% (frequency) and ±0.5dB (94dB)/±1.0dB (114dB). Meets IEC standard 60942 1997-11. Comes complete with two 9V batteries, carrying case and screwdriver.
-
Sentinel -
Seaward Electronic Ltd
The Sentinel series of test instruments has been built to provide a cost effective, yet powerful solution to hipot testing, whether on a production line or in a laboratory environment for compliance testing purposes. With the ability to perform either 5kV AC or 6kV DC dielectric strength tests and up to 500VA AC power output the Sentinel series can aid testing to many international safety standards including IEC, EN, UL and CSA to name but a few.
-
DEL-101 -
Standard Electric Works Co., Ltd
● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.
-
STT-EFT-5K series -
Beijing KeHuan Century EMC Technology Co,.LTD
STT-EFT-5K series group pulse generator is designed to determine a common and reproducible basis for evaluating the performance of electrical and electronic product power lines, signal lines or control lines when subjected to electrical fast transient pulse group interference. The performance of the generator meets the requirements of IEC 61000-4-4 and GB/T 17626.4 standards. Application areas: industrial control, home appliances, medical electronics, communication electronics, components, automation control, etc...
-
DS-0323 -
Ono Sokki
This software analyzes the 1/1 and 1/3 octave bands for 2 - 32 channels (2 - 64 channels when two units are connected ) in real-time from 0.5 to 20 kHz. The filter is compatible with the IEC, JIS, and ANSI standards. The equivalent continuous A-weighted sound pressure level (Laeq) and the single-shot sound exposure level (Lae) are calculated simultaneously by setting measurement time. Variations in level (time series) for each band can be saved for up to 2,000 points.