Showing results: 91 - 105 of 581 items found.
-
CX-W600 -
Shenzhen Chuangxin Instruments Co., Ltd.
It's to determine the stability of electric appliances which are used on a table or on the floorin accordance with IEC 60065 / 1998-07 clause 19.1, IEC 60335-1 / 1991-04 clause 20.1, IEC 60601-1 /1988 clause 24.1, IEC 60950 / 1991 + Amendments, modified, clause 4.1.1,EN 60335-1 / 1994 and A11 / 1995 clause 20.1, EN 60950 / 1992 + Amendments up to 1997 clause 4.1.1,VDE 0700 Part 1 / 10.95 clause 20.1 and Part 3 / 3.96 clause 20.1, VDE 0730 Part 1 / 3.72 clause 20a,VDE 0805 / 11.97 clause 4.1.1Inclined Plane Device is used to test the stability of an apparatus that requires a surface in order to work.The device cosist of a surface and an angle adjusting device with 0- 15 °
-
783106-01 -
NI
400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.
-
Elmeasure India Pvt. Ltd
Multiple branches of load can be monitored togetherCan group the device as 3 phase load and single phase loadFaster communication through RS485 port (Modbus protocol)Simultaneous sampling of Volts and AmpsAccuracy Class 1.0 as per IEC 62053-21 & Class 0.5 as per IEC 62053-22 StandardsDisplays more than 25 parameters
-
TMG -
Mess- & Prüfsysteme GmbH
The partial discharge meter TMG was developed for Partial Discharge tests according to VDE 0434 and IEC 60270.
-
-
-
DTV -
Bitrode, Inc.
Cold Crank Testing to industry standards: IEC, SAE, BCIDischarge capacity performance testing to thousands of amperes
-
TEMPMED -
New Infrared Technologies
TEMPMED is a non-contact body temperature measurement system fully compliant with IEC 80601-2-59:2019 Standard
-
-
JEMStar ll IEC -
Ametek Power Instruments
AMETEK’s JEMStar II has the highest accuracy in the market, provides many communication options and monitors your power quality to make it the ideal choice for any metering application. An impressive color display makes it easy to view power measurements, phasor displays and meter diagnostics. The JEMStar II is easy to use and configure with our intuitive JEMWARE software and the meter display provides a user menu to show and edit configuration details. The JEMStar II has 1 GB of non-volatile memory to store your metering and power quality data for as long as you want. The meter has a single base model that can be used for simple revenue and billing applications as well as more complex power quality monitoring applications.
-
PP1S -
Hsiang Cheng Electric Corp
1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540
-
King Design Industrial Co., Ltd.
*Complies with IEC 61646, IEC 61215 mechanical load test specification. * Air pressure is adjustable, output range is from 2400pa to 5400pa ±5% . * Maximum measurement range: 220 x 260 cm. * Apparatus structure material:aluminum-extruded. * Fixtures and holders can be customized design for requirement of testing module. * Manual operation is simple; manual maintenance is easy.
-
EMCTEST
Meets IEC/EN 61000-4-20, SAE J1752/3, IEC 62132-2 and IEC 61967-2. The GTEM cell is, in principle, a tapered coaxial line (offset septum plate), which is terminated by a hybrid combination of discrete resistors and RF absorbers to achieve a 50 Ohm broadband match. It is applied for Measuring of Emission, Radiated, radio frequency field-immunity test.
-
Fuji Electric Co., Ltd.
Personal surface contamination monitor [IEC 61098/IEC 61256 compliant]. *Innovative plastic scintillation detector for beta rays
-
Emission -
Langer EMV-Technik GmbH
is used to measure conducted emissions (measurements with direct 1 Ohm/150 Ohm-coupling) according to IEC 61967-4 at IC pins.