Showing results: 46 - 60 of 66 items found.
-
40-192A-012-HI -
Pickering Interfaces Ltd.
The 40-192A-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test:
-
40-193A-002-HI -
Pickering Interfaces Ltd.
The 40-193A-002-HI is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
40-191B-012-HI -
Pickering Interfaces Ltd.
The 40-191B-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
40-193A-001-HI -
Pickering Interfaces Ltd.
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
40-194A-001-HI -
Pickering Interfaces Ltd.
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
40-194A-002-HI -
Pickering Interfaces Ltd.
The 40-194A-002 is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
42-203-001 -
Pickering Interfaces Ltd.
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
OTM-XB -
Zensol Automation Inc.
The OTM-XB is the only standalone recorder to use the vibro-acoustic method that detects intermittent and sporadic operational faults on working circuit breakers.
-
A. Eberle GmbH & Co. KG
The fault recorders and power quality analyzers PQI-D, PQI-DA and PQI-DA smart are the key devices for all measurement tasks in low-, medium- and high-voltage grid.
-
Qualitrol
Multi-functional fault recorder including: -- Disturbance fault record (DFR)- Dynamic disturbance recording (DDR) - Phasor measurement unit (PMU C37-118)- Power Quality (PQ Class A)- Travelling wave fault location (TWS to +/-60m) - Impedance fault location- Protocols (61850, Modbus, DNP3) - Sequence of event recording (SOE)- GPS, IRIG and NTP time sync- iQ+ masterstation software.
-
TESLA LITE -
ERLPhase Power Technologies Ltd
The new TESLA LITE is an economical user-friendly multi-timeframe power system recorder: Economical yet complete power system recording for custom applications in smaller substations. Easy to use intuitive software Simultaneous transient fault, dynamic swing and trend recording and event logging Fault location derived from single and calculated currents IRIG-B clock synchronization (modulated and unmodulated) Smallest footprint among recorders allows easy retrofit and installation 12 current, 6 voltage and 38 digital inputs
-
2002 -
Utility Systems Inc.
The Model 2002 DME System is a state of the art, multifunction data collection and analysis system. It is suitable for application in an electrical utility substation or plant environment to produce Sequence of Event (SER), Digital Fault Recorder (DFR), Dynamic Disturbance Recorder (DDR), and Continuous Recorder data in conformance with PRC-002-1 and PRC-018-1. All data recorded by the DME system is stored in IEEE C37.111 format and named in conformance with IEEE C37.232. The system also has a software option to enable the Phasor Measurement Unit (PMU) feature to provide streaming data in conformance with IEEE C37.118.
-
9000 -
Utility Systems Inc.
The Model 9000 DME System is a high performance multifunction data collection and analysis system. It is suitable for application in an electrical utility substation or plant environment to produce Sequence of Event (SER), Digital Fault Recorder (DFR), Dynamic Disturbance Recorder (DDR), and Continuous Recorder data in conformance with PRC-002-1 and PRC-018-1. All data recorded by the DME system is stored in IEEE C37.111 format and named in conformance with IEEE C37.232. The system also has a software option to enable the Phasor Measurement Unit (PMU) feature to provide streaming data in conformance with IEEE C37.118.
-
Platinum 2.5K -
Ametek Power Instruments
For all types of power system events, the Platinum 2.5K Multi-Function Recorder provides all the information you need to capture the complete picture. This comprehensive fault recorder simultaneously performs transient, sequence of events and disturbance recordings, phasor measurements and power quality analysis. All of these functions are performed at the highest level so it will meet your needs of today and the future. In a deregulated environment, the Platinum 2.5K is the best tool to provide the necessary data to increase revenues and retain your customer.
-
Baseline 9400 TDR/ICE -
K&S Engineering and Scientific Ltd
BASELINE 9400 TDR/ICE - the unique cable diagnostic system: - A state-of-the art cable fault locating instrument containing a high speed data recorder, capable of capturing and evaluating 40 million samples of electrical data per second, while also featuring amplifiers, attenuators and an adjustable pulse generator.