Showing results: 451 - 465 of 910 items found.
-
PIT-12 -
Physitemp Instruments
PIT-12 General Purpose Probe for Pressurized Systems - 12'' #304 stainless steel shaft. Diameter is 1/16''. Immersible. Maximum temperature 350°C, Time constant 0.5 Seconds. Shaft Terminated in a sub-miniature Type T Thermocouple plug. 10 foot Sub Miniature Type T extension lead supplied. Not isolated.
-
PIT-6 -
Physitemp Instruments
PIT-6 General Purpose Probe for Pressurized Systems - 6'' #304 stainless steel shaft. Diameter is 1/16''. Immersible. Maximum temperature 350°C, Time constant 0.5 Seconds. Shaft Terminated in a sub-miniature Type T Thermocouple plug. 10 foot Sub Miniature Type T extension lead supplied. Not isolated.
-
629-10 -
Electronic Specialties Inc.
After numerous requests, we are introducing 10 foot version of our popular 629 test lead. This test lead is 10 feet long, with no connectors or reels. This test lead can be deployed for various applications involving the need for a longer reach. Also, there are no connectors or extension plugs to snag, catch or scratch any part of the vehicle.
-
DPM 2000 -
Lascar Electronics Ltd
The DPM 2000 is a 3 digit LCD voltmeter with 12.5mm (0.5") digit height. It features 200mV d.c. full scale reading, a bandgap reference, auto-zero, auto-polarity and a set of annunciators. The meter plugs directly into a DIL socket or can be panel mounted using the bezel and window. Connection to the meter is via two rows of pins.
-
Extech USB200 -
Extech Instruments Corporation
The Extech’s USB200 monitors voltage, current, and charge capacity (mAh) to determine the quality and stability of chargers, power banks, and cables. It’s designed with a standard USB-A connector to plug into a device to be measured. It also has a USB input to test the quality of charging cables by observing the displayed current. The USB Power Monitor measures the output voltage, current, capacity and stability to prolong the charging equipment’s life cycle and memory stores up to 10 readings. Includes protective USB plug cover for storage.
-
DSR-TT -
ZOGLAB Microsystem Co., Ltd.
Original medical probes being resistant to low temperature and free of toxicity and halogen Dual temperature channels for simultaneously monitoring of double-door refrigerators Original fittings for sensor connection, ensures 100,000 plugs Support single DSR connecting to PC via USB interface, and multiple DSR grouped in RS485 or LAN networking for central management
-
LabNation
The logic analyser cable plugs in to the AUX port of the SmartScope, providing 8 shielded probe pins for each of the digital inputs, as well as the external trigger input. Each digital probe has its own ground connector and embeds a small passive filter close to the header, allowing for digital probing without signal cross-talk on the cable
-
4251WF -
ScanTool.net, LLC
OBDLink WiFi features Plug and Play connectivity with your laptop, iPhone, iPod Touch, iPad or any other standard WiFi device. The built-in USB port gives you maximum versatility. Compatible with all model year 1996-2011 cars and light trucks sold in the United States, including all American, European, and Asian vehicles.
-
Pico Technology Ltd.
Pico data acquisition products provide a straightforward answer to your data logging needs.Our data loggers require no power supply and simply plug into a USB port on your PC, or an Ethernet port on your PC or network.Every logger is supplied with PicoLog data acquisition software so you can measure, record and analyze your data.
-
AST Labs
Test cables for tone generators, butt sets, oscilloscopes, digital multi-meters (DMM), and other test equipment that uses specialized connectors like Bed of Nails alligator clips, RJ11, sheathed banana plugs, etc. Our cables are similar and replaces genuine manufacturer cables from Fluke, Harris, Tektronix, HP, JDSU etc.
-
Honeywell International Inc.
To install the optional cable sensor, simply plug it into the detector. The entire length of cable is an extended sensor. Additional 4 foot cable sensors (sold separately) can be connected to extend the cable and increase water sensing area even more. Note: The cable sensor jack is NOT for plugging in a power adapter. Doing so could damage the detector.**
-
DPM 950S -
Lascar Electronics Ltd
The DPM 950S is a 3 digit LCD voltmeter with 19mm (0.75") digit height and LED backlighting. It features 200mV d.c. full scale reading, auto-zero and auto-polarity. The meter plugs directly into a 16-way IDC socket or can be panel mounted using the bezel. An optional IP67 / NEMA 4X bezel (BEZ 900-IP) is available for waterproof applications
-
DPM 2AS-BL -
Lascar Electronics Ltd
The DPM 2AS-BL is an ultra-miniature 31/2 digit LCD voltmeter with 8.25mm (0.32") digit height and LED backlighting. It features a negative rail generator which enables the meter to measure a signal referenced to its own power supply GND. The meter plugs directly into a SIL socket or can be snapped into a panel. Connection to the meter is via two rows of pins
-
HALT -
Integrated Test + Measurement
The Hopper Ash Level Thermocouple (HALT) System is a preventative maintenance and safety tool that continually monitors the levels of ash within a hopper. As the hopper plugs and the ash levels increase, the thermocouples will become insulated from the boiler heat by the ash. Low temperature readings trigger visual and digital alarms which indicate that the hopper has plugged.
-
327/328 -
Sensoray Co., Inc
Model 327 and 328 are bus-to-bus adapters that allow operating a PCI board from a PC/104+ card stack. They allow selection of important PC/104+ signals using jumper plugs, thereby avoiding the requirement of using hardwired settings. Model 327 aligns the PCI board parallel to the PC/104+ boards, while model 328 places it perpendicular.