Filter Results By:

Products

Applications

Manufacturers

Showing results: 721 - 735 of 1169 items found.

  • EMC / RF Test System Engineering / Development & Integration

    EMC Instruments Corporation

    Anechoic chamber, radio isolation room construction, removal, maintenance and repair. System Integration of complete Test System. Development team has the expertise and technical experience and provide a customized service demand, the project includes a full range of EMI / EMS / RF test equipment with neighboring sell and repair reference signal source Noise Generators Signal Generators

  • 1500V Multifunction I-V Curve Tracer

    HT Italia Srl

    SOLAR-515w allows both testing a single-phase (three-phase with optional MPP300) photovoltaic system and verifying I-V curve. Thanks to remote unit SOLAR02, it is possible to test the system complying with the requirement of simultaneity as provided for by the reference standard. SOLAR02 is a datalogger which, synchronized with SOLAR-515w, acquires the data relevant to irradiation and temperature while tests carried out by SOLAR-515w are carried out.

  • DC Josephson Voltage Standard

    Supracon AG

    The system enables a number of calibration and measurement functions for dc voltages:*Calibration of secondary standards*Calibration of linearities and accuracies of dc voltmeters in the measuring range from 0 to ± 10 V.*Extremely exact output of any reference voltages*Direct comparison of two voltage standard measuring systemsNo other measuring system in the world offers such a variety with the highest precision.

  • Spectrally Enhanced Imaging Colorimeter

    LumiTop 2700 - Instrument Systems Optische Messtechnik GmbH

    The LumiTop 2700 combines the accuracy of Instrument Systems’ well-known spectroradiometer CAS140 series with the obvious advantages of imaging colorimetry. Our innovative design merges an RGB CCD camera and a flicker-diode with the high-end spectroradiometer CAS140 CT or D. Using the extremely accurate spectral information of the CAS140 measurements as reference, guarantees spectroradiometric precision across the whole 2D image.

  • Oscilloscope Probe Kit

    6HP-9060 - Prokit's Industries Co., Ltd.

    Switchable X1/X10/X100 attenuation with reference switch positions. Break-resistant center conductor & wide compensation range. Flatter response, sharper leading edges. Faster rise time and replaceable cable probe head tip and ground lead. Max. input voltage: 600V/1200V (DC-peak AC). Includes BNC adapter, IC tip, insulating tip & trimming tool.

  • Solar Cell I-V Characterization System

    VS6821 - Industrial Vision Technology Pte Ltd.

    This system provides cell manufactures and laboratories a new way in testing and measuring photovoltaic cells. Integrated with Steady-State Solar Simulator, it provides complete coverage of testing parameters and measurement requirements by most international standards. Its test methods, procedure & equipment are IEC 60904 compliant. Calibration of reference cell is performed at Fraunhofer ISE in Germany, and is traceable to PTB.

  • Meter Testing System

    ASTel - Radian Research, Inc.

    Three-phase Meter Test Equipment of ASTeL 3.2x.x series system is a fully automatic system enabling simultaneous, multi-position calibration and legalization of electric energy meters. The automatics include power sources, reference standards, stand controllers, photoelectric scanning heads, separating transformers, and other elements of the system. All these elements are controlled through a Windows based executive program.

  • Signal Converters For High-accuracy Angular Measurement

    EIB 1500 series - Heidenhain Corp.

    *Interpolation and digitizing electronics for the real-time digital processing of positions from two scanning heads*Input: incremental rotatory HEIDENHAIN encoder with two scanning heads and distance-coded reference marks (relative orientation of scanning heads: 180° ± 5°)*Output: EnDat 2.2, Fanuc Serial Interface, Mitsubishi high speed serial interface*Integrated subdivision: 16 384-fold

  • Multicoupler

    Novotronik

    Receiver (RX) multicoupler by novotronik are used whenever a common signal from antennas, signal generators or reference clocks has to be distributed to several radio receivers, spectrum analysers or radio scanners. Incoming signals are transmitted without attenuation losses. In addition to our standardized RF devices, we also know to convince in the realization of your individual requirements.

  • Boresight Systems

    Inframet

    Boresight is a process to align optical axis of single system or a series of optical or electro-optical systems with a certain reference optical axis or mechanical axis. Proper boresight is particularly critical in case of multi-sensor electro-optical surveillance systems built from a series of systems like thermal imager, VIS/NIR camera, SWIR camera, laser range finder, laser pointer.

  • Test Fixturing

    ATE Systems

    There are no good measurements without good test fixtures. Ideally the test fixture needs to make the electrical connection between the test instrument and the device-under-test (DUT) and be electrically transparent. ATE has developed fixtures for SMT components, leadless packages, and miniature coaxial interfaces, in such a way that the fixture effects can be removed, and the measurement reference plane can be brought right down to the DUT.

  • Temperature Calibration Software v5.1

    MET/TEMP II - Fluke Calibration

    MET/TEMP II software allows you to easily automate the calibration of a wide range of temperature sensors. It provides a comprehensive temperature calibration solution that allows you to test large quantities of sensors, calculate characterization coefficients, and print calibration reports. You can standardize comparison or fixed point calibrations and use multiple temperature sources or references in one test.

  • Fully Automatic Colorimeter

    DRK103C - Shandong Drick Instruments Co., Ltd.

    (1)5 inch TFT color LCD touch screen, the operation is more humanized, new users can be mastered in a short period of time using the method.(2)Simulation of D65 lighting lighting, using CIE1964 complementary color system and CIE1976 (L*a*b*) color space color difference formula.(3)The motherboard brand new design, using the latest technology, CPU uses 32 bits ARM processor,improve the processing speed, the calculated data is more accurate and rapid electromechanical integration design, abandon cumbersome testing process of the artificial hand wheel is rotated, the real implementation of the test program, a determination of the accurate and efficient.(4)Using d/o lighting and observation geometry, diffuse ball diameter 150mm, diameter of the testing hole is 25mm.(5) A light absorber, eliminate the effect of specular reflection.(6)Add printer and imported thermal printer, without the use of ink and color, no noise when working, fast printing speed.(7) Reference sample can be physical, but also for data,? Can store up to ten only memory reference information.(8) Has the memory function, even if the long-term shutdown loss of power, memory zeroing, calibration, standard sample and a reference sample values of the useful information is not lost.(9) Equipped with a standard RS232 interface, can communicate with computer software.

  • Clock and Data Recovery/Retiming

    Analog Devices Inc.

    Analog Devices provides single rate, multiple rate, and continuous tuning clock and data recovery (CDR) ICs for metro, long haul, DWDM, FSO, instrumentation, and other applications. Our any rate CDR ICs allow easy integration into protocol agnostic applications, automatically locking onto incoming data streams at any rate, from 10 Mbps to 2.7 Gbps or from 6.5 Mbps to 11.3 Gbps, without the aid of a reference clock while reporting the acquired data rate over the I2C interface. With a proprietary dual loop design, our any rate CDR ICs feature fast locking with superior jitter performance.

  • C Series Relay Output Module

    NI

    The C Series Relay Output Module enables you to switch up to eight signals at 60 V maximum DC switching voltage and up to 250 V of maximum AC switching current. For quick reference, every channel features an LED to indicate the state of that channel. The C Series Relay Output Module allows for direct connection to a wide array of industrial devices such as motors, actuators, and DC devices.The C Series Relay Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

Get Help