Showing results: 151 - 165 of 6572 items found.
-
1395B -
Ballentine Laboratories, Inc.
The 1395B TVC. Has better thermal stability than it's predecessor. Measuring ac voltages between 20 Hz and 100 MHz with increased accuracy and reliability. The 1395B can be used as a primary ac voltage standard and/or standard for the calibration of ac calibrators and voltmeters.
-
BVR Series -
IBEKO Power AB
Battery voltage recorders from BVR series are designed to serve as a support tool for cell voltage measurement during battery capacity testing.During capacity testing, cell voltage, temperature, inter-cell connection voltage, and specific gravity should be measured in order to determine failling cells in the string that should be replaced.Furthermore, IEEE standards for stationary batteries applications stipulate periodical measurement of overall string voltage, as well as cell voltage and temperature.The BVR Series is the perfect tool for that purpose. All measurements are automatically saved in device’s internal memory. Additionally, DV-B Win software helps the user to download all measured results. Furthermore, the user can create test reports and export them to various formats.BVR series includes two models: BVR11 and BVR22. These are rechargeable handheld devices intended for performing monthly battery inspections and support tools during capacity testing. The list of the applications of these instruments includes:Efficient supplement to BLU series of battery load units during battery discharge testingMonthly inspections of large battery banksAmbient temperature measurementCurrent measurement using current clampsUSB and Bluetooth communication with PCSimultaneous string voltage and current measurement to analyze a discharge test processThe BVR22 model provides Bluetooth communication with an external density meter, for transferring electrolyte specific gravity and temperature readings.
-
-
VOLTCHEK -
Taurus Powertronics Systems
The VOLTCHEK is a variable non-contact voltage detector, A proximity device which detects the presence of an alternating electric or electromagnetic field. It is used by industry professionals for live or dead voltage determination of outdoor overhead or underground at URD test points. Firstly as a proximity device to determine live or dead situations and then as a touch device to verify the source has physically reached the zero AC field. This is the only equipment capable of testing all voltage from AC 415V to 765kV from a distance, beyond arcing zone.
-
Eclipse Tools
Built-in white LED illumination light provides convenient work in dark areasDetects AC voltage from 90 to 1000 VAC without metallic contactCompact size with pocket clip easily fits into pockets or tool pouchesRed LED and audible alarm if voltage is presentEntire outer surface is non-conductive for safety, helps avoid high voltage shockPowered by two 1.5V AAA batteries (not included)CAT IV 1000V Safety rating.Applications: Electricians, maintenance staff, service and safety personnel, and even homeowners
-
Extech 412355A -
Extech Instruments Corporation
412355A is a Current and Voltage Calibrator and Meter. Precision source for calibrating process devices and measuring DC process signals from 0 to 24mA or as mV in voltage ranges with a super large LCD that displays readings in mA, as a percent of the 0 to 24mA range or as mV in voltage ranges. Additional features include Touch Keypad and five stored calibration values for fast calibrations. Complete with 9V Battery, calibration cable with spade lug terminals, carrying case, neck strap, and AC Power Adapter.
-
CAEN S.p.A.
- 6 or 8 independently controllable full floating channelsup to 64 V- Up to 60 W Max channel output power- High resolution on voltage set- Programmable TRIP parameter- Programmable ramp up / down- Current generator operation in overcurrent condition- Overcurrent programmable protections- Individual remote sense lines- Up to 0,2 mV voltage monitor resolution- Up to 1 mA current monitor resolution- Voltage ripple smaller than 3 mVpp
-
N1200 Series -
Next Generation Instrumental (Shanghai) T&C Tech. Co., Ltd.
N1200 series fuel cell voltage acquisitor is specially developed by NGI for fuel cell R&D and production. It is with compact size, high integration, high reliability and fast data transmission. N1200 standalone supports up to 200 channels. More channels can be tested simultaneously under cascade mode. Voltage acquisition range is from -2.5V to +2.5V, which completely covers the voltage range of fuel cell. Real-time voltage data of total 200 channels can be uploaded within 10ms by adopting 100M Ethernet communication. N1200 PC application software supports platform-based test applications, which allows users to customize test files based on the test requirements and process.
-
Di-Log
Our range of CombiVolt voltage testers are designed to measure AC/DC voltages and continuity. Most models provide LED indication, an audible tone or a combination of both while others have a digital display to give an exact reading, all testers have a non RCD Trip feature
-
-
EE301-DCM-xx -
Executive Engineering
LCD Current Readings:0-80.0 / 40.0 / 20.0. LCD Voltage Readings:0-50.0 / 150.0
-
ERAVANT
A widely used electronic oscillator where the input tuning voltage determines the oscillation frequency.
-
Macom Technology Solutions Holdings Inc.
Voltage Variable Attenuators (VVA) from MACOM offer the ability to control the attenuation level relative to a voltage. Attenuation range is up to 30 dB covering frequency as high as 45 GHz. VVAs feature excellent return and insertion loss along with high IP3 in small SMT packages.
-
Ampstik®+ -
SensorLink
Use the Ampstik+ to safely take accurate current measurements when performing high voltage live-line load checks for balancing, switching, or breaking load. This high voltage ammeter measures in every electric utility setting with a linear current sensor to accurately measure .5A to 5000A, while in voltage environments up to 500kV. The opening of the amp sensor is electronically closed, while external currents are electronically rejected. This design enables the user to measure an individual conductor within close proximity to adjacent conductors without interference errors.
-