Showing results: 3421 - 3435 of 6572 items found.
-
61500 Series -
Chroma Systems Solutions, Inc.
Power:500VA (61501)1500VA (61503)2000VA (61504)4000VA (61505)Voltage range: 0-150V/0-300V/AutoCompact size and weight attributable to advance PWM technologyAC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyLow output impedance for testing IEC 61000-3-2 (61505)Programmable output impedance for testing IEC 61000-3-3LIST, PULSE, STEP mode function for testing power line disturbance (PLD) simulation capabilityIEC 61000-4-11 voltage dips, short and variation simulationHarmonics, inter-harmonics waveform synthesizer for testing IEC 61000-4-13Programmable voltage, current limitComprehensive measurement capability, including current harmonicsHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientAnalog programmable interface3 units combined to 3-phase power outputEasy-use software for operation and IEC regulation testOptional GPIB and RS-232C interface
-
61600 Series -
Chroma Systems Solutions, Inc.
Power:500VA (61601)1000VA (61602)1500VA (61603)2000VA (61604)4000VA (61605)Voltage range: 0-150V/0-300V/AutoFrequency: 15Hz 1000HzCompact size and weight attributable to advance PWM technologyBuilt-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage, current limitOne-key recall for 9 different voltage and frequencyLow output impedance for testing IEC 61000-3-2 ( 61605 )Comprehensive measurement capability, V, Irms, Ipk, Inrush, P, Q, S, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates ON/OFFAnalog programming interface3 units combined to 3-phase power outputEasy-use software for operation and ON/OFF testOptional GPIB and RS-232C interfaceFull protection: OP,OC,OV and OT protection
-
Pulse Electronics
Current sense magnetics are used as a low loss method for sensing AC current in a circuit and also provide electrical and safety isolation between the source of the current and the measurement circuit. The key parameters for a current sense transformer are the rms current rating (to ensure it does not overheat in the application) and the safety and voltage isolation (to ensure it conforms to the end-application requirements).
-
LS2012 -
Lisun Electronics Inc.
• Measure Vrms, lrms, W, PF/Hz; • Measure AC, DC, AC+DC; • Automatic selecting, out of limit alarming, advance the work efficiency; • Voltage range: AC: 5-600V, DC: 1-600V. Current range: AC&DC: 0.005-20A with high measure accuracy. Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit).
-
Aguard Electronics Co., Ltd
The physical transfer of data (a digital bit stream or a digitized analog signal[1]) over a point-to-point or point-to-multipoint communication channel. Examples of such channels are copper wires, optical fibers, wireless communication channels, storage media and computer buses. The data are represented as an electromagnetic signal, such as an electrical voltage, radiowave, microwave, or infrared signal.
-
DMC-1400 -
Martel Calibrators
The DMC-1400 Calibrator fully documents any calibration easily while performing the normal job. No special software is required! It features the ability to test for pass/fail criteria, measure and simulate thermocouples, RTDs, current, voltage, and frequency, and source pulse trains. PLCs, full fuseless protection, and a serial communications port for full control with ASCII commands.
-
IMV Corporation
The principle of Reciprocal Pendulum type Pickup is to induce voltage by reciprocal motion of the seismic mass with a coil in the magnetic field being suspended by a diaphragm or coil spring.. Because of its High Sensitivity and Advanced Linearity, it is suitable for detection of malfunction or deterioration of rotational machineries. Due to its structure, mounting should be done carefully for its direction or angle.
-
4614-5 -
VECTOR Electronics and Technology, Inc.
3U x 160mm Eurocard size for 96-pin DIN connector. Pad-Per-Hole both sides Voltage and ground buses around board perimeter on both sides Press-fit dual-pole terminal blocks accepts 14-20 AWG wire. Pushbutton release for each pole. Terminal block leads extend 1/8" below bord.Available in 2-pole to 16-pole
-
GEPS-2000 -
GF Instruments, s.r.o.
Geoelectric Power Sounder GEPS-2000 is a device for data acquisition and interpretation of deep VES (vertical electrical sounding) as well as for 8 channel profiling (resistivity and IP sections). It can be used for measurements up to 1000 – 2000 m depth allowing both high voltage and high current injection of transmitter current according to real measuring conditions.
-
MIB -
GE Digital Energy
The MIB, a member of the M II family of economical and highly functional digital protection relays, is a microprocessor based relay that provides three phase high impedance differential protection for Substation Bus-bars of any voltage level. Use the MIB also to protect electrical machines like transformers, generators or motors against restricted earth faults.
-
10/10B-HS -
TREK, INC.
The Trek Model 10/10B-HS is a DC stable high-voltage power amplifier capable of precise control of output voltages in the range of 0 to 10 kV DC or peak AC with an output current range of 0 to 10 mA DC or peak AC. The Model 10/10B-HS is configured as a noninverting amplifier with a fixed gain of 1000 V/V.
-
Wuxi IMHOO Technology Co., Ltd.
1)For monitoring the ON/RUN time of AC2)Powered equipment3)Suitable for usage of hourse , factory , etc .4)Time setting from 0 to 99999.99 hours ( 5+2digits ) 5)With back cover6)Input voltage source: Ac 110/220/380V 50-60Hz7) Power consuption: 2.5W8) Mounting : by nuts , or DIN rail 9)Size/weight:70X70X50mm/480g
-
McLAREN Applied Technologies
A compact inductive ignition drive unit which drives two banks of five ignition coils. The drivers are controlled via direct logic signals from a host ECU and provide fire-by-fire diagnostics back to that unit via CAN. The coils can be run at voltages up to 30V with this unit in order to minimize dwell times for optimum response.
-
AMIC-5010 -
Amperis sl
Insulation resistance measurement - 15TΩ: * 50 - 1000 V, in 10 V steps, * 1000 - 5000 V, in 25 V steps ; Memory of 999 results and transmission to PC ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current and function with digital filter ; Measurement of continuity of protection and equipotential connections ; Adjustable alarm limits
-
AMIC-10k1 -
Amperis sl
Insulation resistance measurement - 40TΩ: * 50 - 1000 V, in 25 V steps, * 1000 - 10000 V, in 50 V steps ; Memory, bluetooth keyboard option, heating location ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current and function with digital filter ; Measurement of continuity of protection and equipotential connections ; Adjustable alarm limits.