Showing results: 3706 - 3720 of 6572 items found.
-
TINA-TI -
Texas Instruments
TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages and waveforms. TINA''s schematic capture is truly intuitive-a real "quickstart."
-
DR-700 -
Daerim Electronics Co.
1. Insulation resistance measurement(earth-state, line-cut, line-short, and telephone capacity measuring) 2. Tone & pulse dialing3. Speakerphone for hands free two way conversation4. Subscriber calling5. Last number redial6. Hook and flash function7. High impedance monitor function8. Transmitter mute switch9. Continuous polarity LED indications10. Line powered with high voltage protection11. Water-proof
-
NEO TELE-TRONIX PVT. LTD
This modern Test Set For Instrument Transformer is used for measuring relative errors of Instrument Voltage and Current Transformers. This is developed for reading out the unbalance of any bridge circuit. It also calculates the burden associated to the test sample. In addition to this, it further converts it to ratio and phase error values for presenting them on a LCD screen. With high-tech microprocessor controller, it ensures to provide quick and correct measurements.
-
F30PV -
FLC Electronics Inc
The F30PV is a very fast general purpose linear amplifier having a variable amplification of 0-10 times and capable of bipolar voltage output of ±35V. Any functiongenerator or arbitrary waveform generatoror any othe signal source can be used as an input device. The amplifier's output is linear from DC up to ca 10 megahertz range. It can be used in a wide range of high speed applications.
-
DER EE Electrical Instrument
Meter DimensionPlease indicate meter size Internal Resistance250 , 650, 750, 1200 Sensitivity200A , 250A , 500A, 1mA Pointer ColorAs your color request Scale PlateCustom design according to your drawing LampStandard type is 12V/55mA transparent. If you request special specs., please indicate the voltage and current Install position of the level meterVertical or horizontal Popular spec500A/650
-
Computer Gesteuerte Systeme GmbH
The MCM is designed to drive a variety of brushed motors. This is the CM version of our IMCM. The overload-proof 4-quadrant chopper outputs voltages between 5.5V to 16V up to a constant load of 16A (32A peak). The PWM can be set between 1kHz and 20kHz. The module is protected against undervoltage and overvoltage, shuts down automatically when overheating and is also equipped with a linear current limiting.
-
MFG-3005 -
MCH Instruments Co.,Ltd.
*Frequency range: 0.1Hz~5MHz*Output waveforms: Sine ,triangle, square, positive and negative pulse, positive and negative ramp*Output impedance: 50Ω±10%*Output Amplitude: Not less than 20Vp-p(open circuit)*DC voltage: 0~±10V continuously adjustable*Symmetry range: 90:10—10:90*Rising edge of square: Less than 100ns
-
PS200-1U -
Axiomtek Co., Ltd.
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 17A**+3.3V, 14A**+12V1, 6A**+12V2, 12A**-12V, 0.8A**+5Vsb, 2A*MTBF(hours): At 25°C, 100,000h*Safety: CB, TUV, CE, FCC, C-TICK, CUL, UL, CCC*Dimensions: 150 x 81.5 x 40.5 mm*Compatible with Axiomtek products: AX61120/AX60530
-
44KS3-02 -
North Atlantic Industries
NAI's 44KS3-02 is a 72.5-Watt Power Line Conditioner with holdup time that protects downstream DC/DC converters from transients, low voltage conditions, and power interruptions. This unit accepts +28 VDC input and provides a single output at 72.5 Watts either 22.5 to 30 VDC with holdup time or +16 VDC without holdup time - to all downstream DC/DC converters.
-
CM100 -
General Technologies Corp.
Small jaw: 1.2"(W) x 0.53" (D) (300x13.4mm). Clamp opens up to 1/2 inch (12.5 mm). One rotary switch operation. Large 4 digit LCD display. AC/DC Voltage measurement up to 600 Volt. AC/DC current measurement from 0.001 up to 100 A. Relative measurement. One touch auto zero
-
HA1600A -
Aim-TTi
Compliance quality measurements to EN61000-3-2 and EN61000-3-3Measures peak or rms voltage or current, real or apparent power, power factor, phase etc.Tabular/histogram of 40 harmonicsVoltage/current waveforms displaysContinuous analysis with real-time graphical updateWide range of power connectors available320 x 240 pixel high-contrast displayUSB, RS232 and printer interfaces fittedPC control and documentation software supplied (HA-PC-Link+)
-
MCH Instruments Co.,Ltd.
Is a measurement apparatus capable of visually depicting regular changes in electrical activity, such as an electrical current or signal. The resulting data appears as a waveform drawn on a graph with two axes, where the horizontal X axis represents time and the vertical Y axis indicates voltage. In addition, the luminance of the waveform itself is often referred to as the Z axis, which demonstrates the intensity of the activity measured.
-
CT8017 -
General Technologies Corp.
State of the Art ergonomic design and styling for easier handling and use. Full Auto Ranging range selection. Manual range selection function. Large 3 digit LCD display with analog bar graph. AC/DC Voltage measurement up to 600 Volt. Manual or automatic VDC/VAC selection. DC Current measurement up to 10 A. Resistance measurement up to 32 MOhm
-
HH2205F -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.5%). 3-3/4 Jumbo LCD display 4000 count with symbolic signs. Auto Ranging High Voltage test up to 1000V DC and 750V TRMS AC. Higher Current test up to 20A AC/DC. Diode and Continuity check. Measure Resistance up to 40MΩ. Measure Temperature up to 760oC or 1400oF
-
Frequency Devices Inc.
precision band-pass and band reject (notch) active filters that provide high performance in a compact 32-pin DIP package, with a broad range of fixed center frequencies (fo) from 1 Hz to 100 kHz. Each filter type features a neartheoretical amplitude/phase response along with lowoutput voltage noise enabling these filters to achievea 10,000:1 or better dynamic signal range.