Showing results: 4051 - 4065 of 6572 items found.

  • Loop Calibrator

    Model KM CAL-904-MK1 - Kusam Electrical Industries Limited

    • 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load

  • Enhanced 24 Discrete I/O Channels (0 to 60 VDC, 500 mA/Ch.)

    DT4 - North Atlantic Industries

    The DT4 module (the enhanced version) features 24 programmable channels for either input (voltage or contact sensing with programmable, on-module pull-up/pull down current sources), or output (current source, sink, or push-pull) up to 500 mA per channel from an applied, external 3 – 60 VCC source. These modules can sense broken input connections and whether an input is shorted to +VCC or to ground. Additional features of the DT4 (Enhanced Version) are listed below.

  • Analogue (1kV below) Insulation Tester

    1131 IN - Standard Electric Works Co., Ltd

    ● Hight quality Taut Band movement.● Three insulation test voltages (DC) : 250V, 500V, 1000V.● Two ranges for continuity test : 2Ω & 20Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600Vac.● 200mA continuity short-circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display of external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • Surge and Test Generator

    STG 600 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR STG 600. The STG 600 surge and test generator is a multifunctional cable fault locator for low voltage networks. The surge and test generator is used for cable testing as well as for precise location of high-resistive and intermittent faults in low voltage cables.* Specifically for use in low-voltage networks* High surge energy: 600 or 1000 J** Light, compact and transportable* Single systems for cable testing and faults location

  • Power Quality Analyzers

    APQM-702/APQM-703 - Amperis sl

    *It can be powered from the L phase.*It is intended for use in virtually all types of networks from 64 V to 760 V directly, with special consideration for measurements on low-voltage poles, due to its ease of connection.*It has an independent power supply and is therefore particularly suitable for measurements outside of voltage transformers. It can also be adapted for measurements on DC voltage systems.*Real-time remote configuration and data transfer (GPRS) using a built-in GSM modem

  • New 12v Battery Load Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    battery maximum capacity: 120Ah or 1200CCA(SAE)voltage test range: 7-15VDCoperating voltage: 7-15VDC , storage battery power suppliedmaximum power dissipation: 0.5W aroundoperating temprature: -10°C~50°C;operating humidity: 30%~90% (without condensation)display modes four super bright nixie tube with 0.56 inch ,four different color Led indicator lightkeying: three keying total for using related operation

  • Surge Generators

    Hybrid - Hilo Test

    Surge pulses occur due to direct or indirect lightning strikes in a circuit or by switching transients caused by switching inductive loads or short circuits. This leads to currents or electromagnetic fields causing high voltage or current transients. Surge voltages and currents can reach several thousands of volts and thousands of amperes. Our following Surge generators simulate these disturbances for all the necessary level in accordance with IEC / EN 61000-4-5 and IEC / EN 60060.

  • Relay Protection Test Cabinet

    SFJ018 - Shanghai Launch Electric Co., Ltd.

    SFJ018 relay protection test cabinet uses double carbon brushes regulator, big buttons for regulating AC/DC voltage, current under large loading, small buttons for regulating AC/DC voltage, current under small loading,. The two output channels could work simultaneously. It also take use of digital meters of Grade 0.5, sensor of high accuracy, six digital display stop watch, satisfying requirements for time measurement.

  • Conductivity Electrode

    ALS Co., Ltd

    As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.

  • Data Logger

    Ajinkya Electronic Systems

    Data Loggers are electronic instruments which capture and record data related to physical parameters like temperature, humidity, pressure, liquid flow etc. as well as electrical parameters like voltage, current etc. and reproduce them in a form suitable to the user. The reading of information, storage and reproducibility are the important parameters that define a data logger.Depending on how each of these parameters are handled data loggers can be classified in various categories and have various nomenclatures.Here are the various parameters that user can select from to choose a data logger

  • Data Logger (Category)

    Ajinkya Electronic Systems

    We have been offering to our clients a wide range of Data Logger. These are electronic instruments that capture and record data related to physical parameters, such as temperature, humidity, pressure and liquid flow. Moreover, these also record electrical parameters including voltage & current and reproduce these in suitable form for the user. The reading of information, storage and reproducibility are the important parameters that define a data logger. The various kinds of Data Loggers are different in nomenclature and are identified depending upon the how they handle the parameters.

  • DC Load Simulating Inductors

    Osborne Transformer Corp.

    Osborne has developed a wide range of DC load simulation inductors that are known for the transients they produce. Osborne DC load simulation inductors are unique and innovative because they are engineered to produce a precise time constant current transient during the current charge cycle.Another distinguishing feature of our load simulation inductors is that they produce a precise voltage transient during the current discharge cycle. The resulting test circuit can be used to accurately replace real loads in a variety of circuit simulation applications.

  • Digital Attenuator Operating Frequency of 1 to 20 GHz

    LDA Series - Vaunix Technology Corporation

    The LDA series of Lab Brick® RF and Microwave Programmable Digital Attenuators includes 50 Ohm and 75 Ohm bidirectional RF step attenuators with calibrated operation up to 20 GHz. These USB powered and controlled units require no additional DC supply voltage. They are easily programmable for fixed attenuation or swept attenuation ramps directly from the included GUI. Lab Brick Digital Attenuator API DLL, Linux drivers and LabVIEW-compatible drivers are also available for custom programming applications.

  • Digital Indicators

    NOSHOK, INC.

    NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. The NOSHOK Attachable Loop Powered Digital Indicator can easily be fitted to NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the Hirschmann (DIN 43650A) connector. NOSHOK also offers a dual display model that accepts a wide variety of input signals including thermocouples or RTDs, current, voltage, resistance and process signals. Plug-in option cards are available on several models for field upgrading.

  • Digital I/O Channels cPCI Cards

    GX3232 - Terotest Systems Ltd.

    The GX3232 is a multi-channel 16-bit, analog input and output cPCI module, supporting 32 single-ended or 16 differential input channels and four analog output channels. The inputs can be software configured for differential or single-end operation and are sequentially scanned with a maximum aggregate scan rate of 300 kS/s. Three input ranges are software-selectable: ±10 V, ±5 V or ±2.5 V. Optionally, the GX3232 is available with a high voltage input configuration and supports three ranges: ±60 V, ±30 V and ±15 V.