ENET-A429P -
Alta Data Technologies LLC
eNet-A429P™ is an innovative product that provides “remoting” of ARINC operations on 10/100/1000 Ethernet IP/UDP local area networks (LAN). eNet-A429P is a small, low-power, device ideal for details ARINC signal testing with variable voltaqe control of the first 3 TX channels. Alta has combined the industry’s most advanced 32-bit ARINC FPGA protocol engine, AltaCore™, with a real-time IP/UDP thin server. The customer can implement their application with the same feature-rich application programming interface, AltaAPI™, as used with standard cards – often without even recompiling – the utlimate in code portability.
-
780878-01 -
NI
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9215 performs differential analog input. The sbRIO‑9215 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
781029-01 -
NI
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9215 performs differential analog input. The sbRIO‑9215 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
787814-01 -
NI
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The sbRIO‑9220 helps you perform differential analog input. The sbRIO‑9220 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and … noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
780874-01 -
NI
Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9229 performs differential analog input. The sbRIO‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Non-enclosed modules are designed for OEM applications.
-
780875-01 -
NI
Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the sbRIO‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range. Non-enclosed modules are designed for OEM applications.
-
785479-01 -
NI
Non-Enclosed, ±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9222 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The sbRIO‑9222 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the sbRIO‑9222: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
780588-01 -
NI
Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The sbRIO‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three sbRIO‑9225 channels. Non-enclosed modules are designed for OEM applications.
-
Aplab Limited
- 19” Rack Adaptable- Laboratory Bench Unit- Digital Output Metering- Constant Voltage Current Limit Type Character- Micro Switch Provided for Protection against Shock- 3U High (133 mm)- Power Saving Thyristor Preregulator Technique
-
PLH Series -
Aim-TTi
Single output 120V 90W or 250V 94WLinear regulation - for the best performanceUltra-compact design - uses up less spaceTrue Analogue controls - for ease of useS-Lock function - instantly lock settingsV-Span function - customize the voltage rangeLow current range and current meter averagingDC output switches and "view limits" buttonSelectable remote sense terminals
-
783107-01 -
NI
250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.
-
PDiagnostic Series -
Power Monitoring and Diagnostic Technology Ltd.
The PDiagnostic is a portable system that utilizes Ultra-High Frequency (UHF), Acoustic Emissions (AE), High-Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV) sensors to detect, analyze, and locate the PD signals in real time for a multitude of medium and high voltage electric power equipment.The multi-channel PDiagnostic system locates PD on power equipment down to a meter by utilizing Acoustic-Electromagnetic Combination Location Technique, Time Difference of Signals’ Arrival (TDOA), Partial Discharge Signals Separation (PDSS), and 3D Positioning Technology with PC software included.The system features advanced PD diagnostic capabilities, automatic PD type pattern recognition, and accurate PD location capabilities. The PDiagnostic is an ideal trouble-shooting tool for your PD programs. Severity is determined and maintenance suggestions are provided accordingly.
-
783106-01 -
NI
400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.
-
Low Voltage Adapter -
Corelis, Inc.
High technology, energy efficient, and small form factor products push JTAG interfaces to the limits; low power and high performance means low voltage, high speed, and high drive requirements. Building specialized interface circuits on product Printed Circuit Boards (PCBs) is inconvenient and costly—an out-of-the-box, external solution is needed.The Corelis Low Voltage adapter is an add-on accessory that provides existing scan controllers with an active, plug-in interface to access low voltage scan chains, without sacrificing performance.
-
Frequency to Voltage -
Encore Electronics, Inc.
Encore Electronics offers a complete line of frequency to voltage converters ranging from the economically priced and compact DIN rail mounted Model FL228 to the rack mounted Model 225. For applications requiring performance between these two models, we now offer our FL236 DIN-rail packaged Digital Frequency/Voltage converter, featuring fast response time, low power and compact footprint.