Showing results: 1 - 15 of 162 items found.
-
ZERA® COM5003 -
Powermetrix Systems
The COM5003 Reference Standard is part of the ZERA/Powermetrix high precision measuring instrument series. With the highest accuracy of 0.005 % (50 ppm), the COM5003 presents its new innovative digital technology and extended features for measurement. As a primary standard, the COM5003 is designed for testing current and voltage meters as well as single- or three-phase power and energy meter testing systems. This precise technology is especially useful in metrological institutes, official utility lab applications, and other environments for energy suppliers or manufacturers of electric meters and designed for integration of existing systems. All operation, measurements and data visualizations can be viewed using by the COM5003’s simple user interface and 9“ touchscreen.
-
2250A -
North Atlantic Industries
NAI's 2250A Phase Angle Voltmeter is the most accurate and versatile AC measurement tool in the Synchro/Resolver and LVDT/RVDT marketplace. Considered the industry standard and based on the latest DSP and FPGA technologies, the 2250A substantially extends and simplifies the capabilities of the legacy 2250 model.
-
Signals & Systems India Private Limited
The Single Phase Portable Reference Standard (SPRS-1102) from SANDS is a portable meter test equipment that helps to calibrate the error present in the single-phase energy meter i.e. the meter under test (MUT). The SPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, phase angle etc of the meter under test. It has an LCD display and an alphanumeric keypad to suit the user. It can be interfaced with the PC for analysis. It has the capability of storing 1000 test results.
-
Signals & Systems India Private Limited
The Three Phase Reference Standard Meter (TPRS-1107) is portable equipment from SANDS. The main objective of this device is to calibrate the errors in three-phase and single-phase energy meters i.e. the meter under test (MUT). The TPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, power factor etc of the meter under test. It has an LCD display, an alphanumeric keypad that makes it easy for the user to operate the TPRS. It can be interfaced with the PC for data analysis. It has the capability of storing up to 8000 test results.
-
SY3102 -
Hong Kong Songyang Industrial Ltd.
There are three ports for pulses to output. And its constants can be set automatically or manually. Types of constants can be set also: active power, reactive power, apparent power, voltage, and current.
-
PAA/PLA -
North Atlantic Industries
NAI's PAA and PLA are AC-Powered, Phase Sequence Monitors that protect three-phase loads from damage due to phase reversals or phase absence. These sequence monitors are ideally suited for rugged defense and industrial applications.
-
5002 -
Clarke-Hess Communications Research
The Model 5002 Phase Verification Bridge set comprises passive devices that are used in conjunction with Model 5500-2 Phase Standard and an output null indicator such as a true rms voltmeter, an oscilloscope or a wave analyzer to verify that the Phase Standard is continuing to operate within its specified phase accuracy limits.
-
SY 1018 -
Hong Kong Songyang Industrial Ltd.
Type SY1018 single phase DIN watt-hour meter is a kind of new style single phase electronic watt-hour meter, the meter completely accord with relevant technical requirements of class 1 and class 2 single phase energy meter stipulated in National standard GB/T17215-2002 and international standard IEC61036
-
Quartzlock (UK) Ltd.
The Quartzlock A6-CPS is a board level product designed for synchronising two stable oscillators. A typical example is the locking of a low phase noise OCXO to a rubidium frequency standard. The product uses a digital implementation of a standard phase lock loop.
-
DDS38 -
Shanghai Powoo Industry Develop Group Limited
The DDS38 single phase static watt-hour meter is designed for measurement of electric energy flowing in one or two directions in households and at commecial customers in single phase 2 wire networks. It complies with IEC61036 standard and is manufactured in compliance with the ISO9001 standard.
-
ERAVANT
The phase shifter features a high resolution precision micrometer which allows for finer adjustment sensitivity than a standard micrometer. The phase shifter is an ideal piece of equipment in waveguide systems where broadband phase shifting is required. The phase shifter exhibits a 2.5 dB typical insertion loss and an adjustable phase range of up to 180 degrees.
-
Applied Meters, a.s.
The Reference Standard RS is precision standard meter in single- and three-phase version for electrical power and energy measurement. It is designed to meet all requirements put on a reference standard in a single- and three-phase electricity meter testing and calibration systems. The Reference Standard can be set to any true or artificial mode of operation in three phase system and is capable to evaluate individual quantities in any phase
-
2401 -
The Eastern Specialty Company
TESCO’s Calibration Pulse Processor (Catalog No. 2401) adapts to any Next Generation three phase test board to directly calibrate with three independent single phase standards.
-
STP-18-10-M2 -
ERAVANT
Full band phase shifters are micrometer-driven, waveguide-based phase shifters. The configuration of the micrometer-driven phase shifters is similar to that of level setting attenuators, where the phase shifting is caused by an E-plane dielectric insert in the rectangular waveguide. The amount of phase shifting is directly dependent on the volume of the insert. The VSWR and the insertion loss of these phase shifters are dependent on the frequency. The below standard offering covers the frequency range of 18 to 110 GHz and a phase shifting range of 180 degrees. These micrometer-driven phase shifters are typically used to introduce a certain amount of phase shifting when the absolute number is not a focus.
-
SPS-50 -
Kongter Test & Measurement Co., Limited
SPS-50 standard power source is applied for various tests of analog and digital AC voltage meter and current meter, single/three phase active and reactive power meter, phase angle meter, single/three phase power factor meter, frequency meter, and synchronous-meter, single/three phase active and reactive power meter. It also output 2nd ~63rd harmonics.