Showing results: 76 - 90 of 97 items found.
-
Weshine Electric Manufacturing Co., Ltd
High-voltage Dividers (High Potential Divider) are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they are used to measure alternating voltage (AC), direct voltage (DC), lightning impulse voltage (LI), and switching impulse voltage (SI) systems. High-voltage dividers by HIGHVOLT comply with the relevant IEC standards. The systems are available for both indoor and outdoor use.
-
DWX Series -
ECG KOKUSAI Co., Ltd.
The DWX tester is designed to test other coils and low inductance coils used in high-end electronic components. Through the use of impulse power source with high-speed switch, highly efficient input circuit, and high-speed A/D sampling circuit, the DWX tester can offer a new solution to the low inductance coil tests.
-
VE9036SU -
Vasavi Electronics
6 CHANNEL Microprocessor based Automatic Test System for Automobile Coils, Magnetos, Alternator, Motor Winding. Can Test : Impulse Winding Tester (IW), AC/DC HiPot, Insulation Resistance (IR), Inductance (L), DC Resistance (DCR)
-
MIG0624 -
EMC Partner AG
The MIG0624 current tester is designed to test surge protection devices for low voltage applications (<1000 V). MIG0624 is a current generator delivering a 8/20 µs impulse up to 24kA. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied.
-
MIG0603CLV1 -
EMC Partner AG
The MIG0603CLV1 is a generator for testing varistors. It has circuits with three different source impedances and up to 11 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 200A which is maintained over the entire load range.
-
Transmission Line Pulse Test System -
Impulse Semiconductor Inc.
The Impulse Semiconductor High Current Transmission Line Pulse (TLP) test system is the tool of choice for extracting ESD parameters for transient protection devices in a package, or at wafer level. With accuracy better than 100 milliohms at 40 amps peak current, the Impulse high current TLP is specially tailored to the needs of today's ESD device designers who must accurately measure low values dynamic resistance irrespective of breakdown voltage.
-
MIG0603CLV2 -
EMC Partner AG
The MIG0603CLV2 is a generator for clamping voltage testing of varistors. It has circuits with four different source impedances and up to 15 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 500A which is maintained over the entire load range.
-
19036 -
Chroma Systems Solutions, Inc.
The industry’s first Wound Component Electrical Safety Test (EST) Analyzer that combines impulse winding, AC/DC hipot, insulation resistance and DC resistance test measurement functions. Chroma’s 19036 Wound Component EST Analyzer has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement with a maximum output of up to 40 channels. Capable of outputting and measuring AC100mA/DC 20mA, Chroma’s 19036 is suitable for testing to high power motor standards such as UL 1004-1.
-
ToneGenerator -
NCH Software Pty Ltd
Tone Generator is a sine wave generator, frequency generator and signal generator that lets you create audio test tones, sweeps or noise waveforms using your computer or a PDA handheld. Generate sine wave, square wave, triangular waveform, saw tooth waveform, impulse, white noise and pink noise.
-
COMP0804CAP -
EMC Partner AG
Active flammability test system according to IEC 60384-14 Ed4. For testing X & Ycapacitors up to 1uF. The test system includes control of the nominal AC supply via an integrated variac up to 1800V. Impulse amplitudes are programmable up to 8kV which covers all requirements. X1 capacitors are stressed up to 4kV, X2 and Y4 capacitors up to 2.5kV and Y2 capacitors up to 5kV.
-
Techsquare -
Techimp HQ S.r.L
New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.
-
Techimp HQ S.r.L
The Impulsive Test Synchronization Module (ITSM) is a device aimed at generating a digital synchronization signal, to use the PDBaseII system for impulsive voltage PD test. The digital synchronization signal generated by the ITSM, is synchronized with the voltage impulse of the impulsive source (voltage generator). The ITSM must be connected between the DIN channel of PDBaseII and the output of the synchronization sensor (e.g. capacitive coupler). The ITSM provides also a low voltage signal reproducing the impulsive voltage source.
-
Mess- & Prüfsysteme GmbH
Our high-voltage coupling capacitors are a main component of our partial discharge test stations. They serve to decouple the partial discharge impulses and act as a voltage divider, the output voltage of which is matched to our partial discharge measuring devices (with integrated voltage measurement) and peak voltage measuring devices. These high-voltage components are also available separately in their various designs, sizes, capacities and voltage ranges.
-
PP1S -
Hsiang Cheng Electric Corp
1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540
-
KT-905D -
Kast Eng Co. LTD.
Surge Tester of KAST is divided for the use of 3¡40 §Ç by output voltage, and subdivided into type C of manual decision type, type A of auto decision type, type L of exclusive use for low inductance product test and type P loading printer which can printout its wave form and digital scope. Surge test requires only 0.5 second. Because Surge tester already performs 30 times of Impulse voltage test only for 0.5 second. Turn-to-turn short : phenomenon shorted between the side coils.