Filter Results By:

Products

Applications

Manufacturers

Rectifiers

Convert AC to DC.

See Also: Power Supplies


Showing results: 91 - 105 of 116 items found.

  • S Series Panel Meter

    ST-670 - Standard Electric Works Co., Ltd

    ● DC up to 50A● AC up to 30A● Hz Meter : Measuring Ranges : 45~55 Hz, 45~65 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0● Case and Composition: Acrylic resin front and Bakelite case. Four studs mounting.● Accuracy : Moving coil type:Class 2.0 Moving lron type:Class 2.5 Rectifier : Class 2.0● Color:Black case. white scale plate..● Pointer:Tube or knife-type, color in black or red.

  • F Series Panel Meter

    ST-70U (Three studs mounting) - Standard Electric Works Co., Ltd

    ● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.

  • AC Filament Switching and Line Relays

    Mors Smitt Group

    *Heavy duty Elkonite contact tips*AC and DC versions available*AC versions available with or without internal rectifier PCB*Automated vision system and operator inspection*Comprehensive automated end of line testing*Test Certificates supplied with each relay*Certificate of Conformity supplied with each order*Recertification and repair services available

  • DC Filament Switching and Line Relays

    Mors Smitt Group

    *Heavy duty Elkonite contact tips*AC and DC versions available*AC versions available with or without internal rectifier PCB*Automated vision system and operator inspection*Comprehensive automated end of line testing*Test Certificates supplied with each relay*Certificate of Conformity supplied with each order*Recertification and repair services available

  • DC Standard Load Banks

    Ohm Loads Powertek Inc.

    The DC SERIES load banks are designed for connection to DC Power Supplies , Aircraft Power Converters, Telecom Rectifiers, Batteries, Fuel Cells or any other DC power source. The DC SERIESis ideal for integration into racked test systems or bench - top testing. These standard models are easily configured for other voltage and current ratings.

  • Megohmmeter

    1864-9700 - IET Labs

    The GenRad 1864 Megohmmeter is the choice for more demanding applications. The test voltage can be set to any value from 10VDC to 109VDC in 1-volt steps and to 1090VDC in 10 volt steps. Thus the GenRad 1864 can be set to any common, or uncommon test voltage for ceramic, mica or paper capacitors, or other devices. The reverse resistance of rectifiers can be readily measured; the low test voltages are especially useful in measuring solid state diodes. An additional range on the 1864 Megohmmeter permits measurements up to 200 T (2 x 1014)

  • Rotating Electrical

    WAI Global

    Through its vast distribution network, WAI provides customers in the aftermarket with access to a wide range of product lines they need, when they need them. WAI’s production team is committed to consistently being the First-to-Market with the latest model products. This commitment, paired with the skill and expertise of the team, results in the introduction of more than 500 new products to the aftermarket each year. WAI offers 100 percent new alternators and starters as well as generators, motors, voltage regulators, rectifiers and other components for the Rotating Electrical market.

  • Stick Meters

    Fieldpiece Instruments, Inc

    Stick Meter and is packed with the portability, toughness and modular expandability HVACR professionals expect. This slim-shaped digital multimeter fits easily in your pocket or on your belt in the included case. Features most of the electrical parameters you use everyday including microamps DC for flame rectifier diode tests and capacitance for motor-run and motor-start capacitors. It’s a manual ranging meter and features a rugged ABS plastic housing with an O-ring to block contaminants, MAX hold, hi-voltage and continuity LEDs and beepers, and auto power-off (APO) to conserve battery life.

  • Resistive & Capacitive AC Load Bank

    RCD - Junxy Energy

    RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.

  • Diode Tester

    FEC VF40CM - Frothingham Electronics Corporation

    The VF40CM is intended for testing VF, HALF CYCLE SURGE, and THERMAL RESPONSE/RESISTANCE on small- and medium-power diodes and rectifiers. It can also measure THERMAL RESPONSE/RESISTANCE on NPN and PNP bipolar transistors using an external user-supplied VCB supply.The VF40CM also is sometimes used to measure VZ of low-voltage zener diodes up to the compliance voltage limit of the tester. 20V at 20A is possible.

  • ePortable Load Bank

    Swift - Simplex Inc

    Quick and easy testing of small generators is possible with the Simplex Swift-e Portable Load Bank. Fully self-contained, lightweight and hand transportable, the Swift-e can be used to test and maintain engine generators, inverters, batteries, battery chargers, rectifiers and small UPS systems. Swift-e's are available as AC or DC units with capacities up to 15,000 watts of load switchable in 250W increments.

  • Device Thermal Test Systems

    Thermal Engineering Associates, Inc.

    Thermal test system combines the test and measurement capability of dedicated instruments with the ease of operation and data collecting capability offered by graphical-user-interface-driven software operating on an integrated computer.Diodes (PN, Schottky, LED, varactor, PIN), Stacked Diodes (Hi-V Rectifiers & LEDs), Laser Diodes, Transistors (Bipolar, MOSFET, IGBT) & Diodes, Integrated Circuits (Application & Thermal Test Die).

  • Miller 400D

    44550 - M. C. Miller Company

    No need to select ranges or adjust dials – the Miller 400D provides a direct read-out of resistance with the push of a button• Bluetooth interface allows optional data-logging via a Bluetooth-enabled PC (or PDA)**• Rugged, hard plastic case - safe to use on wet ground – IP67 rating for dust and water intrusion• Resistance measurement range from 0.01Ω to 10MΩ (auto-ranging) • High resolution digital display• Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 82.2Hz (the unit’s operating frequency)• Runs on a set of replaceable D-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source• Performs 10,000 single readings on a fresh set of batteries• Integrates with Universal Rectifiers’ Soil Depth Selector/Multi-Pin Cable Harness System (please see Integration with Universal Rectifiers’ Cable Harness)

  • Watt-MuncherPortable Load Bank

    Simplex Inc

    The Simplex Watt-Muncher is a small DC rated load bank used to test battery systems, AC to DC rectifiers and power supplies, battery chargers, UPS systems and DC generators. The Watt-Muncher provides a variable test load used to measure charge and discharge rates, response, stability and endurance. Corresponding calibrations and adjustments can be made while maintaining a constant, precise, resistive load on the power source.

  • Surface Roughness Meters

    Rinch Industrial Co.,Limited

    This instrument is compatible with four standards of site to measure surface roughness of various machinery-processed parts, calculate corresponding and clearly display all measurement parameters.When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of inductive amount of induction coils so as to generate analogue signal, which is in proportion to the surface roughness at output end of phase-sensitive rectifier.