Filter Results By:

Products

Applications

Manufacturers

Rectifiers

Convert AC to DC.

See Also: Power Supplies


Showing results: 106 - 116 of 116 items found.

  • IGBT Power Supplies - Air Cooled

    Carl E. Holmes Company

    CEHCO The MSA1000 Rectifiers are based on IGBT Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%. The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.

  • Switch Mode Power Supplies-Water Cooled

    Carl E. Holmes Company

    The MSW Rectifiers are based on Switch Mode Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%.The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.

  • Bench Type Panel Meter

    ED-305 - Standard Electric Works Co., Ltd

    ● Precision meters for plant maintenance, field servicing and educational purposes.● Taut Band movement with rectifier type.● Multi terminals (4mm socket) for range selection.● Carbon pointer, mirror scale to eliminate parallax error.● High resistance to shock and vibration.● Accuracy:±1.5% F.S.● Scale length:80mm.● Dimension:107(L) × 117(W) × 53(D)mm.● Weight:Approx. 300g.● Meets CE EN 61010-1 CAT Ⅱ 600V EN 61326-1 (for 0~600V)

  • "Stiff Grid" and Parallel Operation AC Generator Excitation Regulator

    SVRFP - Kinetics Industries

    The Kinetics model SVRFP Exciter/Regulator rectifier is designed and rated in capacity and operating parameters for the application of exciting the fields on an AC generator in parallel with other AC generators and the power system is a "stiff system" in relation to loading. A "stiff system" is a generating system that is of sufficient capacity or the generator is "small" in relation to the system grid, that the AC system voltage under impulse/step loading condition does not require forcing of the generator field to maintain the power grid voltage. Systems are designed with a standard unit service factor to operate within the +10% to -20% nominal voltage rating at 100% current rating.

  • Power Discrete Tester

    Mostrak-2 - ipTest Limited

    M2 test system has multiple test generators which cover static and dynamic test procedures. It is our first truly modular tester which allows for the system to be upgraded and expanded when needed. M2 are designed to get the tester as close as possible to the handler interface and operator at the highest possible speeds. M2 is capable of HV (3 kV) and LV (600A) testing and has dynamic switching capabilities up to 1200V. MOSTRAK systems can test the following device types: MOSFET, IGBT, Bipolar transistor, Diode - rectifiers, Thyristor (SCR) - Triac, Linear voltage regulator (VReg), Transient voltage suppressor (TVS).

  • Earth Ground Meters

    PCE Instruments

    The earth tester determines ground resistance for both specific and ohm resistances. The earth tester is powered by batteries and have a clock timer function (3 minutes), Data-Hold function, a 3 ½ positions LCD display and their dimensions are 163 x 100 x 50 mm. Resistance ranges come from 20, 200 to 2000 ohms. They have a resolution of 10 / 100 mΩ / 1 Ω. The earth tester measure resistance by means of a constant reverse current (approx. 800 Hz, 2 mA). To measure ground voltage a rectifier is used (5 kΩ/V aprox. 40...500 Hz). The earth tester PKT-2630 series have a small format as well as multiple functions.

  • Signal Acquisition and Filtering Technology

    SNAPTrack® - Rycom Instruments, Inc.

    Built on a proven design, and with Pathfinder SAF Technology™ at its core, the SnapTRACK® offers RYCOM’s most advanced signal acquisition and filtering technology. The SnapTRACK® cable & pipe locator offers utility locators FrequencyFlex™ allowing users to adapt the system to their specific needs. Multiple active frequencies allow the user to accurately locate with a minimum of interference while maintaining the ability continue locating past faults and around conduit bends. Passive frequencies identify "live" and charged lines by their naturally occurring electromagnetic fields. The SnapTRACK® offers multiple passive frequencies -- 50Hz, 60Hz, Radio Frequency, Cathodic Protection Rectifier & CATV -- allowing line locating without the use of a transmitter.

  • Electronic Ballast Automatic Test Equipment

    ATE-1 - Lisun Electronics Inc.

    Test series connection, parallel connection and series/parallel connections of the electronic ballast (about 15 kinds of connections), available for various electronic ballast. • With a precise resistance box, tube is substituted for the resistance, can act as many as 6 tubes. Resistance value: 1-4095Ω adjustable. • Measure input parameters (vrms, irms, w, pf, harmonics, etc), output parameters (on-circuit voltage, lamp voltage, filament voltage, lamp current, lamp power, oscillatory frequency), can also test the ballast efficiency, abnormity protection, and power symmetry of partial rectifier effect and etc. • Program controlled AC power source to guarantee the smart choice of input voltage and the frequency. • Equipped with 17 inch LCD controlled machine, specially designed A/D combined with special CPU, has the two left and right testing interfaces to achieve stability of data and high- speed testing. • We can make the special-designed product for you and promise to upgrade the software for free.

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • Turns Ratio Testers

    TRT Standard Series - IBEKO Power AB

    When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

Get Help