Filter Results By:

Products

Applications

Manufacturers

Noise

a signal's fluctuation other than that desired.

See Also: Pink Noise, White Noise, RF Noise, Distortion, NVH


Showing results: 1696 - 1710 of 2094 items found.

  • Air Amplifiers

    Nex Flow Air Products Corp.

    Nex Flow® Air amplifiers are compact, low cost air flow “movers” that are virtually maintenance free. Applications include the venting of fumes and smoke, conveying of low weight materials, and entraining a high volume of air to cool, blow off, and dry. Air Amplfiiers use the “Coanda effect” to draw in the surrounding atmosphereic air while consuming only aminimal amount of compressed air. These products can amplify airflow up to 17 times (depending on the size) resulting in dramatcally reduced levels of noise. Air Amplifiers (also called Air Movers) draw in atmospheric air from the back of the unit as well as having downstream entrainment further amplifying the flow. They are used for cooling and venting. While the force produced for blow off decreases as the amplifier outlet diameter increases, these Air Movers are ideal for cooling because of the high velocity outlet fow and and are much more effective for cooling compaed to air nozzles.

  • Ultrasonic NDT Transducers

    United Western Technologies Corp

    The Quick Change Transducer (QCT) series of transducers that makes changing wedge angle and transducer frequency rapid and easy, saving both time and money. The QCT connects straight into the wedges allowing for many combinations all within one kit. All QC Transducers are fitted with top mounted microdot connectors allowing for seamless transition from one transducer to the next. The stainless steel transducer housing will resist even the harshest working conditions. The emphasis of the QCT is general purpose with a balance of power and resolution, a High resolution version is available upon request.The Quick Change Wedge (QCW) is simple to setup and operate, utilizing incorporated noise dampening material on the wedge. Offered in steel, aluminum and titanium refracted angle. Custom contours, radii and wear pins available upon request.The QCT and QCW series are extremely versatile and can be used in many different applications and in a wide variety of industries and environments.

  • PCI Bus Analog Output Board, 4 Isolated Outputs, 14 Bit

    APCI-3501-4 - TEAM SOLUTIONS, INC.

    4 analog output channels Optical isolation 500 V Settling time 30 µs typ. 14-bit resolution (13 bit for 0-10 V) Output voltage: ±10 V, 0-10 V (switchable through software) Output voltage after reset: 0 V Each output channel has its own ground line (without optical isolation from the others) Driver capacity: 5 mA/500 pF Short-circuit protection, EMI filters Noise neutralization of the PC supply Creeping distance: 3.2 mm acc. to DIN VDE 0411-100 Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary2 digital input channels, 24 V, isolated 2 digital output channels, 24 V, isolated Noise immunity Test level: ESD: 4 kV Fields: 10 V/m Burst: 4 kV Cond. radio interferences: 10 V

  • RF Components

    Copper Mountain Technologies

    Using a Vector Network Analyzer (VNA) for RF component testing for design and manufacturing is based on how the component performs. The analyzer is used in multiple ways from design to manufacturing to tuning, field monitoring and maintenance of antennas, filters, mixers, amplifiers, circulators, isolators, and other RF components. Key considerations component designers should pay attention to when finding an analyzer that fits their needs is a great dynamic range, low trace noise, and fast measurement speed.

  • Acoustic Calibrators

    Castle Group Ltd.

    When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.

  • Iifrasound Monitoring System

    INFRASONITUS - BioAge s.r.l.

    The infrasonic signal, acquired by a suitable microphone, is filtered by an active low-pass filter of the fifth order with a cut-off frequency at 20 Hz, with low noise, then it is sampled and acquired by a 16-bit ADC with a speed of 50 samples. / sec. The amplification factor can be set to 0.1 / 0.5 / 1/10.The infrasonic monitoring system includes a complete diagnostic functionality that performs an exhaustive functional test without the use of other tools: this function is extremely useful when the system is installed on the volcano at high altitudes.

  • Shunt Voltage References

    Analog Devices Inc.

    Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.

  • Phase Locked Loop (PLL) Synthesizer & Translation Loop

    Analog Devices Inc.

    ADI’s industry leading phase locked loop (PLL) synthesizer family features a variety of high performance, low jitter clock generation and distribution devices. The extensive, ever growing family includes over 100 products, optimized for high data rate, low jitter clocking applications. The portfolio features PLLs, PLL/VCOs, and distribution chips, designed for clocking applications where synchronization, clock distribution, and phase noise performance are all vitally important.

  • Digital Audio Snake System

    OmniSnake - En Technology

    The OmniSnake consists of a Stage Box that converts microphone/line-level analog inputs to a multiplexed digital signal, and a companion Base Unit that de-multiplexes to provide individual outputs. Digitizing the analog audio at the source eliminates the potential for ground loops, noise interference and crosstalk. Each Stage Box has 8 inputs, and two Stage Boxes can be linked together via coax to form a combined 16 channels, which is carried over coaxial cable to the Base Unit.

  • Tire Rolling Resistance Test System

    Ono Sokki

    This system measures the rolling resistance of each tire accurately. In addition to the simultaneous measurement of tire loss resistance and rolling resistance coefficient for each drive by mode operation (JC08, WLTC), coasting test, constant acceleration/deceleration test and transient mode test are able to be performed. Furthermore, measurement of driving noise/ vibration of the tire, effect of the tire loss due to the temperature change can be verified by adding options.Conforming the JIS D 4234: 2009 and ISO 28580: 2009.

  • Sound Level Meter

    831C SoundAdvisor - Larson Davis, Inc.

    The SoundAdvisor Model 831C Sound Level Meter is designed to make noise measurement easy. Due to its color display, connectivity, extensive software features and small form factor the SoundAdvisor is an ideal choice for handheld operation. Attended measurements are simplified, with the ability to control and monitor data via any PC or mobile device with a standard web interface. Designed with the acoustic professional in mind, the SoundAdvisor offers an elegant solution for complex needs in an easy to use system.

  • Tunable Laser Source

    Apex Technologies

    AP405xA series tunable laser sources are high performance external cavity Littman tunable lasers combining wide tuning range, high output power and high signal-to-noise ratio. Different wavelength ranges are available between 1000 nm and 1650 nm. Tunable laser sources OEM and stand-alone benchtop instrument versions are available. The TLS benchtop instrument is proposed with a friendly-user software, a touch sensitive screen, GPIB, ethernet , RS-232 and USB controls.

  • RF Frontends

    Becker Nachrichtentechnik GmbH

    Software-Defined Radio (SDR) is an attractive approach for mobile communication architectures in the development and evaluation phase for a rapid prototyping on a flexible platform. SDRs support a wide frequency range. However, for practical use in the field the HF properties are insufficient. The transmit power is limited to a 2-digit mW value. Dedicated filters are required for an effective suppression of out-of-band signals and to improve the noise figure of the receiver chain. Extending SDRs with application-specific RF-frontends achieves optimal RF performance in the field.

  • Profiling Current Meter and Wave

    SeaGuardII DCP Wave - Aanderaa Data Instruments AS

    The SeaGuardII DCP Wave is a 600kHz Doppler Current Profiler able to measure directional wave parameters and currents from a bottom mounted installation.The Acoustic Wave software 5759 used by the DCPS implements unique features to improve the wave measurement accuracy by optimizing the signal to noise ratio.Maximum deployment depth is 40m in normal scatter conditions. The Profiling Current Meter and Waveis available as a self-recording instrument. It can be easily integrated into a real-time system offering reliable two-way communication.

  • NI-9265, 4-Channel C Series Current Output Module

    779334-01 - NI

    4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

Get Help