Showing results: 466 - 480 of 689 items found.
-
MRC ltd.
Tension & compression capability .* 5000 g, wide capacity, highresolution, high accuracy, highrepeatability.* 3 kind display unit, g/oz/Newton.* Separate sensor.* Peak hold ( Max. load ) measurement.* Positive or reverse display direction.* Hand held & stand mounting.* Microprocessor circuit & exclusiveload cell transducer.
-
H261 -
Howell Instruments, Inc.
The H261 Series Temperature Indicator Tester provides accurate testing of the calibration and operation of temperature indicators. This is achieved by simulating thermocouples, resistance temperature devices, and other millivolt transducers. These testers also troubleshoot thermocouples and millivolt sources by measuring their outputs. In addition, they measure thermocouple circuit resistance and harness insulation resistance.
-
ECHO 8 -
Danatronics Corporation
Danatronics offers our newest ultrasonic precision thickness gage line, the ECHO 8 series. ECHO 8 represents our most advanced thickness gage ever combining dual and single element transducers all in one small package. ECHO 8 offers a 3.5” high resolution sunlight readable color display with live A-Scan, use of a wide variety of dual, contact, delay line and immersion transducers from 1-20 Mhz as default and custom created and stored applications setups, B-Scan, datalogger with up to 32GB of SD card memory and interface to Microsoft excel. The ECHO 8 is available in 4 models including the ECHO 8, ECHO 8DL, ECHO 8W and ECHO 8DLW. The vibrate on alarm feature is the world’s first and is great for loud environments
-
Pickering Interfaces Ltd.
Our range of flexible PXI Analog Output modules features high accuracy & high resolution voltage and current sources that satisfy a wide variety of applications in Automated Test, including sensor and transducer simulation. Each product has a number of variants with differing channel counts to closely match a user’s specific requirements.
-
DSK -
North Atlantic Industries
Synchros are transformer-type voltage/current transducers that convert a shaft or other rotating device's angular position and/or velocity to a multi-wire AC electrical signal. Both deliver signals proportional to the Sine and/or Cosine of the shaft angle. A Digital-to-Synchro simulator is used to convert digital angle/velocity commands to corresponding Synchro/Resolver AC signals.
-
DSx -
North Atlantic Industries
Synchros are transformer-type voltage/current transducers that convert a shaft or other rotating device's angular position and/or velocity to a multi-wire AC electrical signal. Both deliver signals proportional to the Sine and/or Cosine of the shaft angle. A Digital-to-Synchro simulator is used to convert digital angle/velocity commands to corresponding Synchro/Resolver AC signals.
-
KANOMAX USA, Inc.
The Kanomax Cabin Leakage Tester pressurizes or depressurizes the automobile vehicle cabin to measure the changes in cabin pressure. The control unit consists of a manometer and pressure transducers. The manometer detects the leakage flow, which is calculated by measuring the nozzle pressure relative to static pressure. The tester controls an adjustable fan to maintain static test pressure.
-
NI
The Power Measurements Conditioner provides voltage and current signal conditioning for a supported data acquisition module or device to make up to four simultaneous power measurements per conditioner. It also includes attenuation for voltage channels up to 2,000 V and has power, communication, and signal lines for current measurements from current transducers.
-
PENKO Engineering B.V.
A load cell is a sensor which transforms the load or force applied to it into an electrical signal. Load cell sensors are based on the strain-gauge principle i.e. a sensor whose resistance varies with applied force. They are the most widely used as load transducers in all areas of weight measurement from retail scales, the process industry and medical applications.
-
Acces I/O Products, Inc.
Analog Output boards are useful when you need an output where the condition is not just an on or off state. Analog Output boards convert digital values generated by software into the analog voltage or current signals required for controlling frequency inverters, valves, sliders, brightness of lights, or things controlled by motors and other mechnical transducers.
-
T4111 -
COMET SYSTEM, s.r.o.
Transducer is designed for temperature measurement at C or F by means of an externaltemperature probe with Pt1000 sensor. Measured temperature is converted to linearized unified signal 4-20 mA. Measured values are displayed on LCD display. It is possible to switch OFF theLCD at all. Current loop has two-wire connection and requires power from evaluation device.
-
PI660 -
Pacific Instruments, Inc.
PI660 - 2 Software Options, 1 Powerful Package! PI660 is the choice software for test management, data acquisition and recording, data display, and network distribution of transducer and other measurement data. It is a 32-bit, multithreaded application available in stand-alone, server and client versions for Windows.PI660 offers two distinct approaches to data acquisition and display:
-
Futek Advanced Sensor Technology, Inc.
Pressure Sensors manufactured in US by FUTEK Advanced Sensor Technology (AST), one of a handful of companies producing high quality pressure sensors, using metal foil strain gauge technology. Metal foil Strain-gauge technology is one of the most common types of pressure sensors in the market and is also commonly known as pressure transducers.
-
Computer Conversions Corporation
The Computer Conversions Corporation POA90-3 is a programmable quadrature oscillator with a built-in power amplifier, capable of driving current loads of up to 200mA. The sinusoidal outputs are 2.5Vrms signals that are phased 90° apart as REF out and REF out +90 (Quadrature), allowing the unit to be used with Synchro, Resolver, LVDT/RVDT, Inductosyn, or similar inductive transducers.
-
WIKA Alexander Wiegand SE & Co. KG
Load pins represent one of the most important components for measuring forces. Existing retention bolts can easily be replaced by these products in existing applications. The application areas range from construction machinery and cranes to stage construction. These force transducers are often used by designers, because, due to their design, they can be directly integrated into the force flow, without taking up space. Since the design requirements for the use of load pins are very individual, the exact layout is important. With WIKA, you will have specialists by your side who already have lots of experience in force measurement.