Filter Results By:

Products

Applications

Manufacturers

Showing results: 2686 - 2700 of 5263 items found.

  • UltraCMOS SP8T RF Switch

    PE42582 - pSemi Corp.

    The PE42582 is a HaRP™ technology-enhanced absorptive SP8T RF switch that supports a frequency range from 9 kHz to 8 GHz. An external VSS pin is available for bypassing the internal negative voltage generator in order for the PE42582 to deliver spur-free performance. It delivers high isolation, low insertion loss and fast switching time, making this device ideal for filter bank switching and RF signal routing in test and measurement (T&M) and wireless applications up to 8 GHz. No blocking capacitors are required if DC voltage is not present on the RF ports.

  • USB to I2C Adapter

    Model JI-300 - Jupiter Instruments

    The JI-300 is a versatile, easy to use PC hosted adapter used to drive I2C communicationsto/from a target device. The desktop unit can be configured to interface a variety of I2Cnetworks. Bus parameters such as clock frequency, duty-cycle, setup and hold times, busvoltage, and pull-up resistor values can be varied. JI-300''s diagnostic features including"excessive clock-stretch", "bus-not-free", and "bus contention" monitoring, as well as statusreporting at the conclusion of each message transaction simplifies I2C trouble-shooting. AWindows software application manages the setup and control of the instrument.Communications and unit power is provided via a USB 2.0 connection.

  • Verification and Validation with SimScale

    SimScale

    SimScale strives to deliver a complete CAE platform to its users, which they can fully trust. In order to meet their expectations, SimScale continues to verify and validate all major features as they are added over time. By verification, SimScale ensures that the problem in hand was conducted properly and by validation, it takes it to the next step to ensure that the results reflect the reality. On a regular basis, multiple validations are performed whose results are compared either to analytical or to experimental data. This page highlights some of the projects performed to validate the features of fluid, structural, thermal and thermomechanical simulation solvers.

  • Dual Display Digital Pressure Sensor [For Gas]

    DP-100L - Panasonic Industrial Devices Sales Company of America

    Panasonic’s compact DP-100L Pressure Sensor with IO-Link features an improved digital display that offers increased clarity and a wider viewing angle. Thanks to a redesign of its circuitry, the low-power-consumption DP-100L Series requires 14% less power during normal operation and when operating in ECO / FULL mode the display is completely shut off for an increased power savings of up to 50% compared to normal operation. The current value and the threshold value can be checked at the same time, so the threshold value can be set and checked smoothly without switching to another screen mode.

  • 6GHz Dual Frequency Synthesizer moduleValon

    5009 - Valon Technology, LLC

    The Valon 5009 Dual Frequency Synthesizer module is our latest offering in high frequency synthesizer sources. These frequency synthesizers are perfect in applications that require a spectrally pure and highly stable signal source or timing clock. Our synthesizers have replaced laboratory generators costing many times more in a number of applications. Each module actually contains two independent sources locked to the same internal or external frequency reference or standard. Having two phase coherent sources in the same convenient package opens up a wide variety of test applications and solutions

  • Analyzer for Total Sulfur in Gas Application

    SGA-1000 - Atom Instrument

    The ATOM SGA-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.ATOM Instrument offers the most versatile total sulfur analyzers available. The ATOM SGA-1000 has the fastest analysis time of any commercially available analyzer allowing user-defined, multiple cycle averaging to improve analyzer performance. The analyzer operating software is both intuitive and user-friendly. In addition, the ATOM SGA -1000 only requires bottled air for normal operation and does not require installation in a shelter.

  • ARINC 429 Test & Simulation Interface for PCI

    PCI-C429 - Avionics Interface Technologies

    4, 8, 16, or 32 Software Programmable Tx/Rx Channels - Programmable High/Low Speed Operation - Concurrent operation of all Tx/Rx Channels at high data rates - Full error injection and detection - Data capture filtering, 100% bus recording, and physical bus replay - Rate-oriented Label Transmission - Label Selective Trigger for Capture/FilteringIRIG-B time code encoder/decoder with free-wheeling modeApplication Interface supporting C/C++, C# and VB.NET Development - Device driver support: Windows, Linux (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • Auto Loading Durometer

    IMADA, Incorporated

    P2 Auto Durometers maximize the repeatability of hardness tests. The P2 features digital speed control to ensure constant speed during hardness tests. The proprietary flexible coupling ensures perfect contact with test samples. All operation and program functions are controlled using the touch screen LCD panel or remotely using an Ethernet connection. Both automated or manual tests can be performed. Dual timers enable recording of the “creep phenomenon” or tendency of the reading to move back as time elapses from the moment the sensor makes full contact with the sample.

  • Bio-Threat Detection & Collection

    IBAC 2 - Teledyne FLIR

    The IBAC 2 is a fully automated bio-detection sensor that can support continual, 24/7, air monitoring or can be set to targeting sampling windows to align to hours of operation. It alarms in less than 60 seconds when a bio-threat is present. IBAC can be configured to support automated aerosol sampling either in conjunction with its’ triggered alarms or at a set frequency sampling time. In wide service throughout the world, IBAC 2 is used to collect and detect aerosolized agents for all four classes of biological threats (spore, viral, cellular, and protein toxins) with low false alarm.

  • Calibrator, 0 to 24 mA, Current, 185 mm, 78 mm, 38 mm, ± 0.5%, 265 g

    72-6694 - Tenma

    *Adjustable 0 to 24 mA current source*Current calibrator drives loads up to 500 Ω*Large LCD display*Sampling Time : Approximately 0.4 seconds*Over Input Indicator : 1*Operating Temperature : 0°C to 50°C ( 32°F to 122°F)*Size : 185 × 78 × 38 mm (7.3 × 3 × 1.5 inches)*Weight : 265 g (0.58 lb) including battery*Requires one 9 V battery - not included*12 month limited warranty *view Terms & Conditions for details

  • Differential Scanning Calorimeter

    DSC-L600 - Thermtest Instruments

    The Differential Scanning Calorimeter (DSC-L600) is a powerful thermal analysis instrument that measures the heat flow of a sample as a function of time or temperature. The DSC-L600 has been designed to be a cost-effective instrument that is well suited for research or QC applications. The instrument communicates with the PC via a RS232/USB connection. The specially designed heat flux plate has demonstrated more than twice the sensitivity than other heat flow type DSC’s on the market. The reproducibility is excellent, and the noise level is virtually unnoticeable due to a precision high gain, low noise differential amplifier

  • L10N & I18N Testing

    TestingXperts

    The world is shrinking with technology, and more and more enterprises are rolling out products across geographies to address global customer base. However, enterprises need the confidence that their product will meet the language and functionality requirements of the local users in the specific regions. At the same time, they also need the right approach to scale operations optimally across geographies and deliver product in the shortest possible time-to-market. The acceptance of an application rests primarily on how its users perceive it. Critical to that success is the applications’ ability to integrate seamlessly with the native language and the cultural landscape of the target market.

  • Test Handler

    Memory Family - Advantest Corp.

    As semiconductors proliferate and continue to increase in complexity, they are found in an ever-expanding array of state-of-the-art applications, including PCs, digital appliances, mobile devices, and automobiles. To meet the demands of this diverse set of end-user requirements and to keep their products differentiated from the competition, device manufacturers continually pursue new technologies, and there are now over 100 IC package types offered. To this end, with time-to-market a critical measure for success, device manufacturers are seeking ways to get better performance from their equipment, while reducing the production time and labor associated with frequent changes in package types.

  • Visual Analysis Tool for GNSS Receiver Data

    Panorama - Safran Federal Systems

    Panorama is the flagship tool when it comes to analyzing receiver data. When engineers use Panorama they spend more time looking at plots and making decisions, instead of making plots and writing reports. Panorama takes receiver data (.csv files) from PANACEA and RxStudio (other ODS products) and turns it into over 60 engineering plots ready to view at the click of your mouse. These plots give engineers and analysts the ability to view summary level data, head to head comparisons, receiver specific results, and 3D LLA replays using STK.

  • Battery Charge And Discharge Test System

    9841 - PRODIGIT Electronics Co, Ltd.

    *Easy user interface*Measure Voltage, Current, Power, KWH, AH, Temperature, Reference Voltage*Accuracy Measure Time*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery. *The test result will be stored to ACCESS data

Get Help