Showing results: 991 - 1005 of 5310 items found.
-
1398A -
Ballentine Laboratories, Inc.
The useable frequency range is from 5 Hz to more than 10 times higher than that listed in the table below, e.g. T2.5-1 volt and T5-2 volt can be used beyond 10 MHz.
-
770 -
Summit
Measure Carbon Monoxide ( CO ) in ambient air. Sensor Type : Electro chemical. Range : 0 to 999 ppm. Functions : Recording ( MAX ), Both audibly and visually, Low battery indication, Elapse time
-
MIchrome 5 Pro -
Fuzhou Tucsen Photonics Co.,Ltd
From the user's point of view, redefining the image acquisition - editing - measurement - report output workflow process, taking into account the best operating procedures, greatly saves the operating time, effectively improving productivity.
-
X-400C -
Meyer Sound Laboratories Inc.
With clean, accurate sound all the way down to 20 Hz, the X-400C shares the sonic characteristics of the X‑800C subwoofer in half the size. Its high peak power brings the thunder every time.
-
RM-1500 /RM-1501 -
Tecpel Co., Ltd.
5 Digits LCD Display. Light Reflex Measurement. Range from 10.00 to 99,999 RPM. Measuring Distance 50 to 300 mm. Event Counter elapsed time. Max/Min/Hold : True Average
-
MKS-05 Terra -
Ecotest
Measurement of gamma and X-ray radiation ambient dose equivalent rate.Measurement of gamma and X-ray radiation ambient dose equivalent.Measurement of surface beta-particles flux density.Measurement of dose equivalent accumulation time.Real time measurement (clock).
-
ANALYSIS 3 -
ZOGLAB Microsystem Co., Ltd.
ANALYSIS 3 provides real-time data collection, makes corresponding graph and datalist updating. Over more, this software keeps PC hard drives as mass memory for storing real time collected data.
-
Crystal instruments
The Post Analyzer application is used for the post processing of previously recorded time stream data. Post processing includes data conditioning, Fourier transform operations, and specialized analyses such as order tracking and octave analysis.
-
SPM-8100FM -
Shimadzu Corp.
The new HR-SPM scanning probe microscope uses frequency detection. his instrument is not only capable of ultra-high resolution observations in air or liquids, but for the first time enables observations of hydration/solvation layers at solid-liquid interfaces.
-
NIRvana® HS -
Teledyne Princeton Instruments
The NIRvana® HS InGaAs focal plane array (FPA) SWIR camera is your versatile scientific imaging solution, delivering both high speed imaging and up to 60+ second exposure times.
-
HORITA Co., Inc.
LED display timer that can be used to time various situations and events such as talent, speakers, presentations, experiments, etc. The LED display has a brightness control and the 0.8" characters are large enough to be read across a room.
-
MKS-U -
Ecotest
Measurement of gamma and X-ray radiation ambient dose equivalent rate.Measurement of gamma and X-ray radiation ambient dose equivalent.Measurement of surface beta-particles flux density.Measurement of gamma and X-ray radiation dose equivalent accumulation time.
-
Neaspec GmbH
Based on high-stability scanning-sample Atomic Force Microscope optimized for optical nanoscopyOptical focusing unit accepts visible, infrared and even terahertz illuminationTwo independent module bays allow imaging & spectroscopy at the same time
-
DPO7OE -
Tektronix, Inc.
The DPO7OE series optical probes with a DPO70000 real-time scope deliver the performance and advanced debug capabilities designers need to fully troubleshoot 400G PAM4 signals, up to 56 GBaud, and reduce time to market.
-
HT-315 -
MRC ltd.
Resolution: 0.01% RH, 0.01 degreeMx, MIn measurmentRS 232 PC interfaceResponse Time 5 to 30 seconds typicallyRange 0 to 80 ,32 to 176 . 10 % to 95 % R.HDEW pont.Range -25.3 to 48.9