Filter Results By:
Products
Applications
Manufacturers
PC 104
Hardware and software compatibile with PC bus in a very compact, stackable 3.16"x 3.8" modules.
-
product
PC-104/PCI-104 DAQ & Communication Cards
PC/104 Single Board Computer modules include embedded DAQ, PC/104 DAQ, and PC 104 add-on peripheral modules - perfect for space limited applications.
-
product
Intel 80486 DX2 Processor Board
MS 1500
- PC 104 bus and ISA bus interface- Facilitates design of scalable architectural solution for Embedded System- Back plane eliminated by self-stacking PC 104 bus- Substantial reduction of development time, cost, as well as risk- Helps to Faster time-to-market / timely product productions- Used for LCA Simulation Project- Intel 80486DX2 @ 33MHz- 512Kbytes of STATIC RAM, 2048 Kbytes of FLASH PROMS- 64 Kbytes of DPRAM- External Interrupts- RS232 Serial Interface- Watchdog Timer- External Bus Interface
-
product
Analog Multiplexer Board
104-AIM-32 PC/104
The 104-AIM-32 is an analog signal multiplexer conforming to the PC/104 standard. The card will multiplex and condition 16 differential or 32 single-ended analog signals before passing them to an analog-to-digital converter card like the 104-AIO12-8. A system may comprise one to seven of these cards in tandem with one 104-AIO12-8 A/D converter board. The 104-AIM-32 card may be used as part of a large data acquisition system. The 104-AIM-32A Kit consists of one 104-AIM-32 and one 12-bit 8-input A/D board.
-
product
Internal DAQ Cards
PCIe, PCI, PC/104, CAN
PC data acquisition cards are particularly suitable for stationary measurement applications. Outstanding in this category are the PCI(e) multi-function cards PCI-BASEII and PCIe-BASE on which you can plug different measurement and control modules to optimize the price-performance ratio.
-
product
PC/104-Based Data Acquisition (DAQ) And Control Products
A small form factor embedded computer board, typically intended for use in small, space-constrained industrial control or vehicles systems. The standard size of these modules is just 3.550 × 3.775 inches (90 × 96 mm). The name PC/104 comes from the original IBM computer known as the "PC", and the number of pins used to connect the cards together (104). PC/104 boards are typically stacked on top of each other using stackable bus connectors and four mounting holes at the corner of each module. This provides a much more rugged, embedded computer that can be used in harsh environments such as those found in military or industrial applications.
-
product
VLF Diagnostics System
PHG 80 TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 80 TD. The combination of the PHG 80 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
product
VLF Diagnostics System
PHG 70 TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)