Showing results: 31 - 45 of 132 items found.
-
LSR-3230 -
W.M. Hague Company
* no fixture or probe cards on top side * 2, 4, and 6 wire test capability * touch screen operation * high performance DC electrical tester * high throughput - low running cost
-
779770-01 -
NI
The PCI‑4065 makes AC/DC voltage, AC/DC current, and 2‑ or 4‑wire resistance measurements, as well as diode tests. It is ideally suited for OEMs, educational laboratories, or other cost-conscious test and measurement applications.
-
780152-01 -
NI
The USB‑4065 makes AC/DC voltage, AC/DC current, and 2‑ or 4‑wire resistance measurements, as well as diode tests. It is ideally suited for OEMs, educational laboratories, or other cost-conscious test and measurement applications.
-
779771-01 -
NI
The PCIe‑4065 makes AC/DC voltage, AC/DC current, and 2‑ or 4‑wire resistance measurements, as well as diode tests. It is ideally suited for OEMs, educational laboratories, or other cost-conscious test and measurement applications.
-
778572-27 -
NI
32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module—The PXI‑2527 is a high‐voltage PXI multiplexer switch module that is ideal for medium‐ to high‐density automated test applications. Featuring high-power electromechanical relays, the PXI‑2527 is the perfect front end for the PXI DMM modules, offering simple channel expansion for a variety of measurements. The PXI‑2527 supports multiple channel configurations including 64x1 1‑wire, 32x1 2‑wire, and 16x1 4‑wire. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
780587-27 -
NI
32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module—The PXIe‑2527 is a high‐voltage PXI multiplexer switch module that is ideal for medium‑ to high‑density automated test applications. Featuring high-power electromechanical relays, the PXIe‑2527 is the perfect front end for the PXI DMM modules, offering simple channel expansion for a variety of measurements. The PXIe‑2527 supports multiple channel configurations including 64x1 1‑wire, 32x1 2‑wire, and 16x1 4‑wire. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
TSBC TRBC -
Computer Conversions Corporation
The TSB Series are miniature, high performance, continuous tracking, synchro or resolver to digital (BCD) converters and angle indicators employing a type 2 servo loop, designed for military and industrial control applications. They will accept any 3 wire synchro or 4 wire resolver input over a frequency range of 50 to 1200Hz. and convert it into 0 to 359.9 degrees or +/-179.9 degrees, TTL compatible BCD data.
-
AIT -
Computer Conversions Corporation
The TSb series are miniature, high performance continuous tracking synchro or resolver to digital (BCD) converters and angle indicators employing a type 2 servo loop, designed for military and industrial control applications. They will accept any 3 wire synchro or 4 wire resolver input over a frequency range of 50 to 1200Hz. and convert it into 0 to 359.9 degrees or +/-179.9 degrees, TTL compatible BCD data.
-
Datexel
Signal IsolatorsDatexel manufacture a large range of Signal Isolators. The DAT511 is a loop powered isolator with 3000 V galvanic isolation between the input and output. It is a 2 wire device so there is no external wiring. The DAT511H is similar but is Hart compatible. The DAT4035 is a universal input signal (Thermocouples, RTD's, mV, Volts, mA, resistance and potentiometers) conditioner with 2000 V isolation between the input and output and it is PC programmable. It is a 2 wire loop powered device. The DAT4135 is similar but it is a 4 wire device so it has the ability to boost the output or provide a voltage output.
-
40-200-008 -
Pickering Interfaces Ltd.
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Elcontrol Energy Net S.r.l.
NANOVIP® TWO™ is a modern, powerful, portable network analyzer developed for professional analysis of consumption and power quality of the most complex electrical networks.It can be used on single-phase, two-phase, three-phase (3 or 4 wires balanced) networks, low and medium voltage.
-
3380P -
Chroma ATE Inc.
The 3380D/3380P/3380 test system have 4 wires HD VI source and any-pins-to-any-site high parallel test (multi-sites test) functions (512 I/O pins to test 512 ICs in parallel) that can meet the upcoming higher IC testing demands.
-
3380D -
Chroma ATE Inc.
The 3380D/3380P/3380 test system have 4 wires HD VI source and any-pins-to-any-site high parallel test (multi-sites test) functions (256 I/O pins to test 256 ICs in parallel) that can meet the upcoming higher IC testing demands.
-
CPM-10 -
Chuan Sheng Electronics Co., Ltd.
CPM-10 Multifunction Power meter measure single phase 2 wire ,single phase 3 wire, three phase 3 Wire and 3 Phase 4 wire systems with high accuracy measurement for parameters such as voltage, current ,active power, reactive power, apparent power, power factor ,frequency, effective energy (V,A,W,Watt-Hr,Var,Var-Hr,VA,PF,Hz), having LED display and standard communication RTU Modbus RS485..Optional functions 1 set relay output,1 analogue,1 RS485 (ModbusRTU Mode) or 1 pulse output. Most suitable for power management,remote input /output, alarm and remote signal control uses needs.Case depth 120mm only, easy panel mounting installation
-
40-201-004 -
Pickering Interfaces Ltd.
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.