Showing results: 1 - 15 of 659 items found.
-
-
-
MS-420 -
Martel Calibrators
The Loop Calibrator is a multi-purpose process loop tool that offers high accuracy in an ultra-small, rugged package. A single pushbutton selects one of five current outputs (4, 8, 12, 16 or 20 mA), which can drive up to 300 Ohms, or can act as a 2-wire simulator with an external loop power supply of up to 30 VDC.
-
ZHX7-0.009-200-1486 -
COM-MW Co., Ltd.
Loop Antenna, Frequency 0.009~200MHz, Linear Polarization, N-Female
-
MZC-310S -
Sonel S.A.
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
Model KM CAL-904-MK1 -
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
EM-6874 | 20 Hz – 30 MHz -
Electro-Metrics Corp.
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
Schwarzbeck Mess Elektronik
Circular shielded loop sensorto determine the magnetic field strength36 turns AWG 7/41diameter 133 mmdistance gauge 7 cm includedMIL 461E RE101 or RS101 alternative test procedures.
-
A.H.Systems, Inc.
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
Non-Linear Systems
The CM-1TB + XL-1 are modern digital current loop-powered meters that convert standard loop current to engineering units. They feature high accuracy and a large 0.6-inch LCD display. Proven reliability combined with low cost has earned these meters world-wide acceptance, with thousands in use.
-
6500 LC -
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
MZC-304 -
Sonel S.A.
# Measurements of impedance in a short circuit loop.- L-PE circuit,- L-N, L-L circuit,- L-PE(RCD) circuit - without tripping the circuit breaker > 30mA.# Low voltage resistance measurement:- continuity measurement - DC current +200mA with wire resistivity reset- low current resistance measurement with accoustic signalling,
-
EM-6879 | 10 KHz – 30 MHz -
Electro-Metrics Corp.
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
Megger Group Ltd.
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
TX916 -
Aegis Pty. Ltd.
The Loop a Line has been a Telstra standard for 20 years. It is probably the simplest time saving device available for contractors and technicians. Once fitted to the far end of a line you can switch between Open, Short, Connect, 600 ohm, and Tone modes allowing all installation and fault location to be performed from the one end without having to go back and forward from one end of the line to the other.