Showing results: 121 - 135 of 659 items found.
-
-
H30 Series -
Ferrites India
AlmiCo, Ferrite, NdFeB, SmCo5, Sm2Co17 magnets are tested and their B-H and MH loops are plotted using Ferrites India make H30 Series hysteresis loop tracers. The complete system consists of a magnetizer to magnetize the test piece, an electromagnet and a BH Loop Plotter. Magnets with coersivity as high as 13 kOe and more can also be tested.
-
TCXO -
Epson Toyocom
A TCXO (Temperature compensated crystal oscillator) is a crystal oscillator with a temperature-sensitive reactance circuit in its oscillation loop to compensate the frequency-temperature characteristics inherent to the crystal unit. Epson's are classified into two types. One is a Direct-Type TCXOwith a temperature compensation circuit built into the oscillation loop. The other is an Indirect-Type TCXO with a temperature compensation circuit outside the oscillation loop, in which the oscillation frequency is therefore indirectly controlled.
-
-
-
AEM-DRK -
Chuan Sheng Electronics Co., Ltd.
The AEM-DRK multi-loop power meters are designed for multi-loop power measurement. It has 2 kinds of circuits which are single-phase 21 loops, or three-phase 7 loops. Also, it can be operated with different circuits, and applied on various occasions that will significantly reduce the cost.
-
88-PRO -
Laurel Electronics, Inc
The 88-PRO Process Meter may be connected directly to a 4-20 mA, 10-50 mA or 1-5 mA current loop, with no need for additional power to the meter. This is because the meter is powered directly by the current loop, developing a maximum voltage drop of 2.5 V.
-
ADF4371 -
Analog Devices Inc.
The ADF4371 allows implementation of fractional-N or interger-N phase-loacked loop (PLL) frequency synthesizers when used with an external loop filter and an external reference frequency. The wideband microwave VCO design allows frequencies from 62.5 MHz to 32 GHz to be integrated
-
TerraTEM24 -
Monex Geoscope Pty Ltd
The new generation terraTEM, the terraTEM24, has been designed to acquire high‑quality transient electromagnetic data from a wide variety of sensors ranging from remote inductive and B field sensors through to single loop and coincident loop configurations.
-
-
NMTI 2 -
Metra Blansko a.s.
A modern multipurpose quantity-to-current loop converter designed for installation in switchboards.
-
VI Control Systems Ltd.
The Group3 controllers - the CNA and DNA - have a built-in PID algorithm, that allows them to perform local closed loop control. A controller, combined with a Group3 analog Hall probe forms a compact, inexpensive way to implement closed loop magnet control.
-
J2101A -
PICOTEST Corp.
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
J2100A -
PICOTEST Corp.
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
SY020 -
Synectic Electronics
The SY020 Pulse Rate Converter can be linked to any frequency generating device e.g. flow meters, which gives TTL, pulse Reed switch or coil output, converting the frequency to an analogue signal. This can be 4-20mA loop current or a voltage output. The 4-20mA version unit is loop powered.