Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
865 -
The Eastern Specialty Company
This instrument is used to check the correctness of polarity markings on transformers. In operation, the two leads carrying the test current are connected to one of the transformer windings. The other two leads from the indicating meter are connected to the other winding.
-
SF-2001 -
Shanghai Launch Electric Co., Ltd.
SF-2001 interference discriminant PD detector is featured by high sensitivity and wide usage. It is mainly used to test partial discharge for transformers, instrument transformers, cables, bushings, capacitors, generators and other high voltage apparatus.
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
XWRM-10 -
The Motwane Manufacturing Company
The Motwane make XWRM-10 is a dual channel 10A rated, Transformer Winding Resistance Meter designed and developed aftere xtensive research on challenges and requirements of testing of various Transformer winding resistance. The instrument has One Current channel and two Resistance Channels. The instrument provides a large open circuit voltage of 42Volts, for fast charging of the highly inductive windings of transformers, to provide stable resistance values in minimum time. The XWRM-10 is intended to replace complex bridge set up with a single compact instrumentThe XWRM-10 is based on 4-wire measurement methodto measure low resistance accurately. The instrument iswell protected against inductive kickbacks offered by theinductive windings and gives stable reading on varioustypes of transformers.
-
TTRM 102 -
Scope T&M Pvt, Ltd.
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
HDZK -
HD Power Test Equipment Co.ltd
Low voltage short circuit impedance test is to identify the shock of short circuit on the transformer on the operation, which is the direct method of checking the winding distortion after transformers hit by mechanical forces during transportation and installation.Short circuit impedance test is an important parameter to decide the running or disassembling inspection for transformer .Transformer Short Circuit And Impedance Tester is a new development instrument suitable for testing low voltage short short circuit impedance 35kV transformer in the field and labor
-
KCTS-8000 -
Knopp Incorporated
The Knopp Current Transformer Testing System (Type KCTS-8000) is designed to measure the accuracy of instrument transformers having 1 or 5 ampere secondaries and primaries of up to 8000 amperes. The system uses a high accuracy multi-range current transformer as a reference standard. All ANSI standard burdens are included. The phase angle and ratio errors of the transformer-under-test (TUT) are measured by the built-in Knopp Automatic Transformer Comparator.
-
KCTS-8000 -
The Eastern Specialty Company
The Knopp Current Transformer Testing System (Type KCTS-8000) is designed to measure the accuracy of instrument transformers having 1 or 5 ampere secondaries and primaries of up to 8000 amperes. The system uses a high accuracy multi-range current transformer as a reference standard. All ANSI standard burdens are included. The phase angle and ratio errors of the transformer-under-test (TUT) are measured by the built-in Knopp Automatic Transformer Comparator.
-
SF2801 -
Shanghai Launch Electric Co., Ltd.
SF2801 high voltage capacitance bridge measures precisely capacitance CX and dielectric loss tanδ for various of insulation materials, power cables, insulation bushings, instrument transformers, transformers and other electrical high voltage equipment under frequency voltage.
-
Eltel Industries
The ANSI Potential Transformer Burden Model PB-96-ANSI is designed for loading the Voltage transformers during accuracy tests as per ANSI standard C57.13. The PB-96-ANSI is a dual input ANSI burden providing the inputs of both 120V & 69.3V. It can be used along with the ELTEL Automatic Instrument transformer Test Set. AITTS-98 to test VTs as per ANSI standards.
-
KVTS -
Knopp Incorporated
The Knopp Voltage Transformer Testing System is designed to measure the accuracy of instrument transformers having 120 volt secondaries and up to 14,400 volt primaries (special order for up to 36,000 volt primaries is available). The system includes a control console which contains the control circuitry, ANSI standard burdens, and the Knopp Automatic Transformer Comparator. The Knopp precision and loading transformer set is also included (as pictured) and is connected to the console via a special cable.
-
KVTS -
The Eastern Specialty Company
The Knopp Voltage Transformer Testing System is designed to measure the accuracy of instrument transformers having 120 volt secondaries and up to 14,400 volt primaries (special order for up to 36,000 volt primaries is available). The system includes a control console which contains the control circuitry, ANSI standard burdens, and the Knopp Automatic Transformer Comparator. The Knopp precision and loading transformer set is also included (as pictured) and is connected to the console via a special cable.
-
TTRM 101 -
Scope T&M Pvt, Ltd.
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
921A -
Arbiter Systems, Inc.
The Arbiter Systems®, Inc. Model 921A Combustible Gas Meter is a rugged, portable instrument that measures total combustible gases (TCG) in oil-filled transformer nitrogen gas blankets. TCG measurements have been shown to be good indicators of transformer health.