Showing results: 76 - 90 of 107 items found.
-
HDLT -
Hention Electrical Equipment Co., Ltd.
This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.
-
TRT Standard Series -
IBEKO Power AB
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
NEO TELE-TRONIX PVT. LTD
We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.
-
2000A -
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed “TEMPERATURE RISE TEST BENCH FOR MEDIUM VOLTAGE SWITCH BOARDS” to measure rise in temperature at various points as mentioned in standard at junctions. The set-up consists of a True RMS Constant Current Source (to maintain the Current within + / - 1 % of set value with Digital Indication), PC based control system, Temperature data logging on PC, Servo-Controller and other indications. Digital voltmeter Primary Voltage) indicates the position of auto transformer (variac).
-
eDAQ-1553 -
Avionics Interface Technologies
One or two dual redundant MIL-STD-1553 bus interfaces - Transformer and Direct bus coupling supported - Two 10/100/1000 Mbit/s Ethernet LAN Interfaces - Streams MIL-STD-1553 bus data in standard IRIG 106 Chapter 10 format. - Compatible with 3rd party recorders and telemetry tools - All captured MIL-STD-1553 bus data provided with timestamps - Full error injection & detection capabilities - Works with AIT’s Flight Simulyzer™ GUI Analyzer/Simulator software
-
GDJB-PC6 -
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
1.This tester with standard 6 phase voltage, 6 phase current output,2.Voltage 125V/phase, current 30A/phase, 6 phases in parallel can up to 180A.3.Digital Signal Processor Microcomputer.4.Not only test the traditional relays and protectors, but also test the modern micro computer replays, special for transformer differential protection and transfer equipments.
-
ASTel -
Radian Research, Inc.
Three-phase Meter Test Equipment of ASTeL 3.2x.x series system is a fully automatic system enabling simultaneous, multi-position calibration and legalization of electric energy meters. The automatics include power sources, reference standards, stand controllers, photoelectric scanning heads, separating transformers, and other elements of the system. All these elements are controlled through a Windows based executive program.
-
T-1007 -
Compact Power Company
The Titan Series T-1007 Auto-transformer is used to conveniently scale the standard OV to 130V / 260V full scale Titan AC Power Source/Frequency Converter output to either X .5 stepdown (OV to 65V) or X2 stepup (OV to 520V). It has a 1.2 KVA power rating with excellent bandwidth and voltage regulation.The unit is of toroidal design, making it approximately half the size and weight of a comparable stacked laminate transformer. It is center filled with epoxy for isolation and durability, and features simple 1/4" bolt center mounting.
-
CD23/223 -
Validyne Engineering
The CD23 and CD223 Digital Transducer Indicators are designed for use with variable reluctance and differential transformer transducers. The CD23 accepts input from a single transducer, and the CD223 accepts two switch-selectable inputs, with Zero and Span controls for each input. The indicators provide 5 Vrms, 5 kHz carrier excitation voltage to the transducer(s) and solid state circuitry to amplify, demodulate and filter the transducer output signals. A 3 1/2 digit front panel display is standard, with a 4 1/2 digit display optionally available.
-
National Technical Systems
Fourier Transform Infrared Spectroscopy (FTIR) is a standard technique used in the identification of contaminating materials on the surface of printed circuit boards (PCBs) and around the leads of electronic components (BGA, capacitors, resistors, inductors, connectors, diodes, oscillators, transformers, IC, etc.) on printed circuit assemblies (PCAs). Additionally, FTIR can be used for “simpler” identifications, such as determining a specific type of plastic or rubber compound.
-
LVDT I/O Cards -
Computer Conversions Corporation
100% Transformer Isolation is offered for all AC I/O, and various Isolated DC converters are available as standard product, eliminating concerns for ground-loops, ground interjected (intermittent and ghostly) field noise, inductive surges, differing potentials, and high voltage field transients from effecting the card itself, the sensitive ISA bus backplane and any other device or system sharing these signals.
-
National Technical Systems
Fourier Transform Infrared Spectroscopy (FTIR) is a standard technique used in the identification of contaminating materials on the surface of printed circuit boards (PCBs) and around the leads of electronic components (BGA, capacitors, resistors, inductors, connectors, diodes, oscillators, transformers, IC, etc.) on printed circuit assemblies (PCAs). Additionally, FTIR can be used for “simpler” identifications, such as determining a specific type of plastic or rubber compound.
-
72-8364 -
Tenma
Type K Surface Temperature Probe Surface probe is ideal for flat stationary surfaces such as molds, heating elements, integrated circuits, transistors and transformers. Very low sensor element mass enables fast response measurement time. Type K thermocouple temperature probes are commonly used with all types of industrial temperature controls and measurement equipment, and are compatible with Tenma handheld thermometers and digital multimeters that include temperature function. All are terminated with standard Type K plugs. See the complete line of Tenma Thermocouple Probes and Accessories
-
Eltel Industries
Fully pre-wired comprehensive turn test system. *Suitable for CTs up to 6000A & VTs up to 132kV. * Precision to (0.005 class) internal multi-ratio standard CT. * Internal 4KA current source. * State-of-the-art Instrument Transformer Test Set AITTS-98 with computer & printer interfaces. * Electronic potential divider facilitates testing any VT ratio upto 132kV. * Current & potential burdens.
-
FW3 -
North Atlantic Industries
The FW3 function module provides IEEE 1394b/AS5643 (Mil1394) support on each of its three nodes, which are configured as 2 nodes with 3-ports and 1 node with 2-ports. AS5643 defined flight ready robustness and active transformer isolation to enable longer cable lengths (20 meter) between nodes. Together these standards provide the deterministic and redundant communications protocol required for Vehicle System (Flight Control) Networks. The FW3 multiple ports per node configuration allows the user to create tree, daisy-chain and looped topologies needed to optimize cable length and weight while creating redundancy.