Filter Results By:

Products

Applications

Manufacturers

Showing results: 2296 - 2310 of 2773 items found.

  • PXIe-2746, 2.7 GHz, Quad 4x1 PXI RF Multiplexer Switch Module

    780587-46 - NI

    PXIe, 2.7 GHz, Quad 4x1 PXI RF Multiplexer Switch Module—The PXIe‑2746 is a PXI RF multiplexer switch module that is ideal for switching RF signals up to 2.7 GHz in production test applications. The high channel count of the PXIe‑2746 makes it well-suited for test systems that require switching a large number of RF signals, such as switching several devices under test to a single channel on the RF analyzer. It also features onboard relay counting for relay monitoring.

  • PXIe-2747, 2.7 GHz, Dual 8x1 PXI RF Multiplexer Switch Module

    780587-47 - NI

    PXIe, 2.7 GHz, Dual 8x1 PXI RF Multiplexer Switch Module—The PXIe‑2747 is a PXI RF multiplexer switch module that is ideal for switching RF signals up to 2.7 GHz in production test applications. The high channel count of the PXIe‑2747 makes it well-suited for test systems that require switching a large number of RF signals, such as switching several devices under test to a single channel on the RF analyzer. It also features onboard relay counting for relay monitoring.

  • PXIe-2529, 128-Crosspoint, 4x32 OR 8x16, 2-Wire PXI Matrix Switch Module

    780587-29 - NI

    128-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or an 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXIe‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.

  • Pen type Conductivity Meters

    Bestone Industrial Ltd.

    Pen conductivity meter is a precision instrument for test solution US value. Simultaneously display the U.S. value and temperature. CT-3031 Pen conductivity meter is a precision instrument used in the test solution mS value. MS value and the temperature is displayed at the same time. Its stable performance, full-featured, easy to operate and so on. Making it the field and laboratory testing and control of enterprises and institutions uS value. Widely used in the monitoring of the chemical, pharmaceutical, electronics, food and other industries

  • Stand Alone and Secure Data Acquisition

    LogMessage 5000 - Delphin Technology

    The LogMessage 5000 is equipped with 16 universal analog inputs. The inputs are designed to cope with high voltages between individual channels. The LogMessage 5000 therefore has no problem measuring non-isolated signals.LogMessage 5000 is an independently operating data logger for acquiring, monitoring, computing and storing measurement data. An internal data memory enables uninterrupted storage of up to 60 million measurement values.Delphin customers are especially impressed by the system's intuitive method of configuration and the many options provided by the device.

  • Two-way Wireless Temperature and Humidity Data Logger with LCD

    RFRHTemp2000A - MadgeTech, Inc

    The RFRHTemp2000A is two-way Wireless temperature and humidity data logger with LCD. Transmits up to 2000' maximum (outdoors unobstructed). Built-in memory also stores data internally. This device is calibrated traceable to N.I.S.T. and is available with a Calibration Certificate. The RFRHTemp2000A is ideal for both industrial or laboratory applications including supply chain storage facilities, incubator monitoring and HVAC studies. Designed with external humidity and RTD based temperature sensors, the device provides a fast response time for both parameters.

  • Intelligent Temperature Water Level Recorder

    HR8800 - HighReach Measuring & Controlling System Co.,Ltd

    The HR8800 water level recorder is a groundwater monitoring instrument with external power supply and internal battery self-power supply. It can be used for long-term recording of water depth (pressure) and temperature. It is all stainless steel structure. The recorder contains water level and temperature sensor, and the built-in large capacity is not easy. Loss memory and high-capacity long-life lithium battery, all functions are integrated in the instrument with a diameter of 24mm metal, suitable for water level measurement Of surface water, groundwater and marine environment.

  • Fixture Interface Module 2 Test Matrices

    OTP2 module no.193 - LXinstruments GmbH

    PXI offers the optimal approach to validation and production testing. You can meet timing, synchronization, and throughput requirements across devices. PXI is a robust PC-based platform for measurement and automation systems, supported by software. PXI combines PCI electrical bus characteristics with CompactPCI's modular Eurocard packaging, and then adds special synchronization buses and important software functions. PXI is both a powerful and cost-effective platform for applications such as manufacturing test, military, aerospace, machine monitoring, automotive, and industrial test.

  • 8U 21 Slot VME64/64X Enhanced Crate

    VME8100 - CAEN S.p.A.

    short circuit protection, Over / Undervoltage protection, Over temperature protection. Remote monitoring and control take place through CAN bus, Ethernet, USB and RS232 interfaces. The crates are also SBC controlled via graphic OLED Display, provides Automatic Daisy Chain and supports Chained Block Transfers (CBLT). User-friendly control software completes the VME 8100 features. The Unit is powered by 92 ÷264 Vac, 50 ÷ 60 Hz, power factor 0.98% (230VAC).

  • ARINC 429 Bus Interfaces

    AIM GmbH

    AIM’s  > ARINC 429 test, simulation, monitoring and analysis modules use our field proven Common Core hardware design giving you the best performance, best feature set and highest functional integration on the market. The use of SoC (System on Chip) based core designs with multiple processors for real time bus protocol and application support, massive memory and IRIG-B time code encoder/decoder functions are standard. The latest versions also support avionics discrete I/O.

  • PXIe-2525, 64‐Channel, 2 A, Multibank, 2‐Wire PXI Multiplexer Switch Module

    780587-25 - NI

    64‐Channel, 2 A, Multibank, 2‐Wire PXI Multiplexer Switch Module —The PXIe‑2525 is a high‐density PXI multiplexer switch module that is ideal for routing signals within automated test systems. It uses electromechanical relays to perform immediate switch operations in one of the following 2‑wire multiplexer configurations: 16 bank 4x1, octal 8x1, quad 16x1, dual 32x1, and 64x1. The PXIe‑2525 also features onboard relay counting for relay monitoring.

  • LIN Interface Device

    NI

    LIN Interface Devices are bus interfaces for developing applications with the NI-XNET driver. The NI-XNET device-driven DMA engine couples the LIN bus to host memory to minimize message latency. You can import, edit, and use signals from LDF databases in integrated LIN databases. LIN Interface Devices work well for applications requiring real-time, high-speed manipulation of many LIN frames and signals, such as hardware-in-the-loop simulation, rapid control prototyping, bus monitoring, and automation control.

  • PXI FlexRay Interface Module

    NI

    PXI FlexRay Interface Modules provide two fully functional FlexRay interfaces, allowing an individual electronic control unit (ECU) to be connected to the interface when other cold-start nodes are not available. You also can use the interfaces individually to connect two separate FlexRay networks while maintaining full performance on each interface. PXI FlexRay Interface Modules work well in applications such as hardware-in-the-loop (HIL) simulation, rapid control prototyping, bus monitoring, and automation control.

  • NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    783311-01 - NI

    ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.

  • PXIe-2524 , 128‐Channel, 2 A, Multibank, 1‐Wire PXI Multiplexer Switch Module

    780587-24 - NI

    128‐Channel, 2 A, Multibank, 1‐Wire PXI Multiplexer Switch Module —The PXIe‑2524 is a high‐density PXI multiplexer switch module that is ideal for routing signals within automated test systems. It uses electromechanical relays to perform immediate switch operations in one of the following 1‑wire multiplexer configurations: 16 bank 8x1, octal 16x1, quad 32x1, dual 64x1, and 128x1. The PXIe‑2524 also features onboard relay counting for relay monitoring.

Get Help