Showing results: 856 - 870 of 2798 items found.
-
Harmonic Distortion Analysis -
ZETLAB Company
The software is used for automatic measurement of the harmonic distortion factor and voltage r.m.s. of signals coming to the input channels of FFT spectrum analyzers. Adjustment to the frequency of the main component is performed automatically. The program is based on the measurement of the voltage r.m.s. of higher components by an external or internal reference signal.
-
National Technical Systems
Forced entry testing is conducted on building envelope and system components such as doors, windows, wall panels and escape hatches as an attempt to penetrate or distort an edge in order to disengage a fitting or device from its mountings and allow access. The US Department of State has developed a standard that all building envelope and system components used in both domestic security and overseas facilities are required to achieve. NTS conducts all forced entry test in their DOS approved facility in accordance to the SD-STD-01.01 standard. All testing is witnessed by DOS personnel with NTS providing reports on all tests performed.
-
Tropel® FlatMaster® -
Corning Inc.
Tropel® FlatMaster® Surface Form Analysis System Fast and Precise Measurements of Ground, Lapped, Honed, Polished and Super-finished Components. The Tropel® FlatMaster® offers industry leading performance for surface form measurements to precision component manufacturers. Our non-contact optical technique analyzes the entire surface of the part in seconds, regardless of its size or complexity. The FlatMaster provides five nanometer resolution and a standard accuracy of 50 nm (2.0 μ). It rapidly and accurately measures flatness, line profile, radius and other surface parameters on a variety of materials and surface finishes.
-
Bloomy Controls, Inc.
Bloomy’s Multipurpose Module for SLSC provides a convenient location in an SLSC system for applications ranging from a simple rearrangement of signals to installation of circuits and components. Both front panel connectors are mapped to screw terminals, through holes, and surface-mount technology pads thus accommodating a wide variety of components. Breakout areas for all rear transition interface (RTI) pins simplify integration into SLSC-based systems. On-board power supplies (±15VDC, +5V, and +3.3V) are also made available for the user’s analog and digital circuits. The module features a considerable amount of available board space for user applications.
-
E50 -
Sciences et Techniques Industrielles de la Lumière
E50 series is part of the STIL ChromaPoint detectors.All the optical fibers are passive components, graduated index silica fibers with a 50µm core, an E2000/APC connector for the connection with STIL controller and an FC/APC connector for the connection with STIL optical sensor head.
-
1433 Series -
IET Labs
The 1433 Decade Resistors are primarily intended for precision measurement applications where their excellent accuracy, stability, and low zero resistance are important. They are convenient resistance standards for checking the accuracy of resistance-measuring devices and are used as components in dc and audio-frequency applications.
-
4613 -
VECTOR Electronics and Technology, Inc.
62 contacts (31 each side) on 0.100" centers. 3-Hole Solder Pads for interconnecting multiple component leads.I/O mounting area for 37-pin D-sub and ribbon cable connectors. Mounting bracket and hardware kit included (P/N HD36B).
-
X3000 -
North Star Imaging Inc.
The X3000 is North Star Imaging’s newest standard system. Whether you are inspecting small or large components, the X3000 is the best option for customers needing a compact system with unique capabilities generally available on a larger X-ray or CT system.
-
Sanwa Electric Instrument Co., Ltd
LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component. In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value.
-
MAG-203D -
MCH Instruments Co.,Ltd.
Features:*Advanced circuit design with imported components ensure minimum accuracy deviation.* Signal frequency: 10Hz~1MHz, ±3%*Wave form:sine and square≤0.5*Intensity of output signal: ≥10Vp-p*60dB accurate attenuate in 6 steps
-
MA-LML01F -
Hachmann Innovative Elektronik
Our test adapter MA-LML01D connects LR measuring devices to LRM string parts. Due to the flexible realisation of the LRM-part it is possible to evaluate mechanical non-standardized string parts, as they can be found in switch components, relays or integrated voltage displays.
-
MTE Meter Test Equipment AG
MTE offers a broad range of products and solutions for the online gas-in-oil monitoring of transformers (online DGA). With its individual and modular system components MTE provides the optimal customer oriented solution for utilities, industries and transformer manufacturers.
-
TruView Prime -
Creative Electron
The TruView Prime is a fully motorized radiography system developed to meet the stringent requirements of electronics assembly and component inspection. The TruView Prime is professionaly built - something hard to find in entry level systems in the TruView Prime's price range.
-
Aerotech, Inc.
Built for durability and rooted in 50 years of expertise, our motion and positioning products are known worldwide for delivering superior precision, accuracy, consistency and throughput. Standard or custom, component or system – we have precisely what you need.
-
Camlin