Showing results: 481 - 495 of 839 items found.
-
778966-01 -
NI
The PCI-6511 is an industrial digital input interface, with eight banks of isolated channels. If a computer or application fault occurs, the PCI-6511 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
779081-01 -
NI
The PCI-6510 is an industrial digital input interface, with a single bank of isolated channels. If a computer or application fault occurs, the PCI-6510 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
41-670-103-AABBCC -
Pickering Interfaces Ltd.
The 41/43-670-103 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 2 channels of 5 or 6-wire or 4 channels of 4-wire.
-
STHVP/STHVE -
HK Film Capacitor Ltd
High Voltage Pulse Current for medium frequency applicationHigh Voltage DC / AC Voltage applicationCapacitor can be discharged at rated voltage directly without any protective component and with ambient Temperature up to +105CHigh Voltage Decoupling and SnubberingVoltage MultiplierInduction heatingAct as discharge capacitor to trigger laser, X-Ray and Tesla CoilFor high voltage capacitor bank or arrayHigh Voltage Power Supplies
-
ED-M Series -
Falcon Electric, Inc
*Isolated 400Hz, Three-Phase Input; Single-Phase Output*Eliminates Phase Imbalance and Associated Harmonics*50, 60 or 400Hz Operation and Frequency Conversion*Superior Output Voltage Regulation*Pure Sinewave Output*True Double Conversion Design*Wide Operating Temperature Range*Military Rugged, Lightweight Rackmount Design*External Battery Bank Options for On-line UPS Operation
-
GCS -
Teledyne Marine TSS
The Teledyne TSS Gyrocompass Changeover System (GCS) has been developed to ensure that your navigation system is continuously supplied with heading information from a bank of up to four connected heading devices, such as the TSS Meridian or Saturn gyrocompasses. The selection of the heading source can be carried out either manually or automatically. Retransmission circuits are housed in a rugged enclosure suitable for bulkhead mounting.
-
41-670-001-AABBCC -
Pickering Interfaces Ltd.
The 41/43-670-001 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
41-670-003-AABBCC -
Pickering Interfaces Ltd.
The 41/43-670-003 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 2 channels of 5 or 6-wire or 4 channels of 4-wire.
-
3160 -
TSI Inc.
Automated Filter Tester 3160 is the most advanced automated tester available for challenging filters and filter media with submicrometeraerosols. It can be used to test both low- and high-efficiency filters and filter media, up to 99.999999% efficient (eight 9’s),or penetrations down to 0.000001%. The 3160 uses a bank of atomizers and the TSI Electrostatic Classifier to challenge a filter or filter media with known-size, monodisperse particles.
-
42-837A-101 -
Pickering Interfaces Ltd.
The 40-837A-101 (PXI) and 42-837A-101 (PXIe) are 75Ω 2x2 RF matrices with 1 bank in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
40-837A-101 -
Pickering Interfaces Ltd.
The 40-837A-101 (PXI) and 42-837A-101 (PXIe) are 75Ω 2x2 RF matrices with 1 bank in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
42-837A-001 -
Pickering Interfaces Ltd.
The 40-837A-001 (PXI) and 42-837A-001 (PXIe) are 75Ω 2x2 RF matrices with 1 bank in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
40-837A-001 -
Pickering Interfaces Ltd.
The 40-837A-001 (PXI) and 42-837A-001 (PXIe) are 75Ω 2x2 RF matrices with 1 bank in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
PA72DIOS6016 -
APPLICOS
The PA72DIOS6016 is a multifunctional digital design core. The FPGA allows for implementing many different custom applications. The connector has 64 Input/Output pins which can be assigned as TTL I/O or as differential inputs. 128 MByte of DDR2 memory is available to the FPGA, and an onboard EEPROM allows for storing values in non-volatile memory. The I/O bank voltage can be FPGA-selected between 2.5 and 3.3 Volt.
-
AD-1 -
D'Amore Engineering llc
The AD-1 Amplifier Dyno is a tool that is designed to be used any place an amplifier exists. It can be used in a lab or production line to test true amplifier power output, quickly and easily. It is simple menu driven, does not require a computer, and cannot be cheated as the load banks are internal. It can be used in an automotive audio install shop to test true amplifier output while the amplifier is installed in the customer's vehicle.