Showing results: 226 - 240 of 280 items found.
-
40-652-003 -
Pickering Interfaces Ltd.
The 40-652 range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. Each multiplexer provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300s on hot or cold switching. User connections are made via a 50-way D-Type connector which is fully support by our comprehensive range of cables and connector accessories.
-
64970 -
Lisle Corp.
Replaceable in-line fuses protect both the meter and tester in the event a high current source on the vehicle is left on. The multimeter is bypassed with the switch during connection in case of a power surge. The tester and meter can remain connected until other computer systems shut down, isolating the drain. As a convenience, stacking banana connectors are used on the tester. This allows voltage to be measured on various locations on the vehicle during the drain test, using standard test leads.
-
PHD-HMM-48-1 -
High Power Pulse Instruments GmbH
*High current wafer-level and package-level 98 Ω HMM probing with grounded DUT*Built-in high surge 48 Ω pulse reflection suppression resistor up to 80 A peak*Fast rise time < 0.5 ns due to low inductance GND loop*Variable pitch from 50 µm to 5 mm*Tungsten replacement probe tips*SMA pulse force pigtail*Compatible to PHD-3001A interface*High reliability
-
Model 253 -
Telebyte, Inc.
FEATURES: DB9 Data Port; Compatible with PC/386/486; Full Duplex; Surge Protection. Adding an RS-422 interface to a PC is now a snap. The Model 253 Interface Converter does this for full duplex signals at data rates up to 19.2 KBPS, without requiring any AC or DC power. With only TD, RD and ground, the Model 253 provides operation over 8,000 feet of twisted pair into a load of 120 Ohms.
-
L3C-HD -
Teledyne Marine Bowtech
The Teledyne Bowtech L3C-HD is a low cost fixed focus miniature high definition camera. Its housing is manufactured with high quality titanium, rated to either 1,000m, 4,000m or 6,000m operating depth.The camera is fitted with a fixed focus wide angle lens. This provides a 67° diagonal angle of view in water. The Sapphire window is highly scratch resistant and 99.8% opitcally pure. The camera features built-in reverse polarity and surge protection.
-
8006He -
Sealevel Systems, Inc.
Optimized for sensing up to 24V inputs, the 8006He PCI Express digital I/O interface provides 16 optically isolated inputs for connection to devices including sensors, switches, pushbuttons, and other user inputs. The inputs can sense both AC and DC voltage while providing optical isolation, which eliminates spikes and surges present in industrial environments. The board is PCI Express X1 compliant and is compatible with any PCI Express slot.
-
SWG-12 (SWG-32) -
Kharkovenergopribor Ltd.
• testing cable insulation with DC (rectified) voltage up to 32 kV;• conditioning faults by burning faulty cable insulation with current up to 100 mA;• pre-locating cable faults with the reflectometer RIF-9 based on the pulse reflection method (TDR), voltage wave oscillation method (DECAY), impulse current envelope (ICE) method and arc reflection method (ARC / ARC multi-shot);• pinpointing cable faults with the acoustic method with up to 2000 J surge wave generator and a suitable signal receiver.
-
UL 30 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR UL 30. The UL 30 receiver is used together with a ground microphone (BM 30) and a surge voltage generator (SSG, STG) to pinpoint cable faults. With the coil integrated in the BM 30 for runtime measurement, the device determines the time difference between the magnetic and acoustic signal. This particularly offers special advantages when d ealing with faults difficult to locate acoustically.* Built-in speaker* Splashproof design* Large, illuminated display* Lightweight
-
NEO TELE-TRONIX PVT. LTD
Test Sets For Diagnostic Testing are designed to test Oil Resistivity, Tan Delta, High Voltage Surge Comparison, etc. These test sets are automated instruments used to measure electrical features to insulate transformer oil, liquids and varied other insulating materials. They are ideal for revealing different localized problems and varied weak spots in the insulation. These modern testing sets are designed to provide high accuracy in results. In addition to this, they are easy to maintain testing sets available to ensure accurate readings.
-
EMS-PT30C -
Progressive Industries
Progressive Industries Portable Electrical Management Systems (EMS) offer quick and easy RV electrical protection. A true plug-and-play application with no installation required. You will feel secure with multi-mode surge, voltage, polarity, and lost/open neutral protection. Each unit includes a digital display, scrolling continuously through the power source information: voltage(s), current frequency, error code, and previous error code (if applicable). Additionally, the computer is driven by state of the art microprocessors.
-
PP1S -
Hsiang Cheng Electric Corp
1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540
-
72-7295 -
Tenma
The 72-7295 is a 40VDC Laboratory Grade Switching DC Power Supply with precision coarse and fine output voltage and current limiting controls. The output Overvoltage protection protects voltage sensitive load by instantly shutting down the supply when the output voltage goes beyond the set voltage due o line surge or otherwise. Current limiting control with automatic cross over of constant voltage and constant current modes makes this unit ideal for R&D work in laboratory situations.
-
CommFront Communications
Rated to perform at temperatures between -40°F and 185°F (-40°C and 85°C), our rugged industrial-grade RS232 / RS485 / RS422 / TTL serial converters are almost indestructible. These industrial-grade serial converter products support multi-drop RS485 / RS422 networks and come with 600W surge protection, 15KV ESD protection, selectable end-of-line terminators, and optional 2500V opto-isolation circuitry, which ensure crisp data signals without interference for all types of installations.
-
Shanghai Guantu Technology Co., Ltd.
Inrush Current Generator Standard: IEC61008, IEC61009, I61051/61643, ANSI C62.31, C62.33, C62.35, TU K20, K21, K44, K45, UL943Inrush Current Generator Features1. LCD screen display, built-in computer control, man-machine dialogue, easy to operate.2. Program-controlled high-voltage power supply, high voltage stability and precision3. Imported non-inductive high-power resistors are used to ensure the consistency of surge waveforms4. The main switch adopts electronic switch discharge mode, and the output polarity is automatically switched
-
Syscompact 2000 -
BAUR Prüf- und Messtechnik GmbH
Fault location with Syscompact 2000. The Syscompact 2000 is a multifunctional cable fault location system designed for modular 19" rack technology. The integrated surge and test generator is used for cable and sheath testing as well as for precise location of high-resistive and intermittent faults. The SYSCOMPACT 2000 is preferably used in low- and medium-voltage networks for fault location up to a cable lengths of 65 km. * Fast and reliable * Precise, dependable cable fault location High performance * high voltage unit* Integrated proven cable fault pre-location methods