Showing results: 1021 - 1035 of 2304 items found.
-
J2111A -
PICOTEST Corp.
The current injector is one of the most versatile of the injector products. Coupled with the G5100A, or other equivalent function generator, it is capable of performing small signal load steps up to 40MHz, with very fast rising and falling edges. Using the G5100A, also allows the rise and fall times to be controlled, various waveforms or even arbitrary waveforms. This can be used to simulate the effects of many different types of loads, including high speed digital circuit loading, which is often largely dynamic.
-
SE-UDPS -
Salland Engineering
Load boards for applications like mixed signal, analog and RF require active components. To drive these active components multiple utility power supplies are needed. The SE-UDPS from Salland Engineering is an economical way of adding more utility power supplies to your Advantest™ V93K to drive op-amps, buffers, relays and switches. The SE-UDPS extends the usefulness of your current fleet of V93Ks. You can also minimize the need to add external power supplies on your load boards.
-
KHZ43201 -
Beijing KeHuan Century EMC Technology Co,.LTD
The KHZ43201 voltage probe is a standard low resistance test probe, which meets the technical requirements for this product in the CISPR16-1 and CISPR14-1 test equipment. When measuring the interference voltage of the power grid, the artificial power supply network cannot be used at the load port, and sometimes it is necessary to use a voltage probe to measure the interference of the signal port, the load port, and the antenna port. The input impedance of the voltage probe to the ground wire is greater than 1.5KΩ, which can protect the input terminal of the receiver.
-
40-157-001 -
Pickering Interfaces Ltd.
40-150/151 modules have 8xDPST or 12xDPST power relays, suitable for switching inductive/capacitive loads up to 5A at 250VAC. 40-155/156 modules have 8xSPDT or 16xSPDT power relays and 40-157 is configured as 8xDPDT. Power relay modules are intended for switching heavy AC or DC loads or for slave switching large external relays, contactors and solenoids. The 40-150 series of power relay module are suitable for applications requiring switching of either mains voltage or DC current.
-
Van Leeuwen Test Systems BV
A chassis dynamometer smoke tester (CDST) is used to test diesel emissions when the engine is under load. This is of course a much more realistic test than the commonly used free acceleration test. It is also better for the diesel engine.During a CDST test an automatic test cycle is performed, whereby the emission is measured at different engine loads. The monitor shows checks and actions to perform before the test, shows real-time measuring data and instructions for the driver during the test, and the end results after the test.
-
Del-Tron Precision, Inc.
Del-Tron’s crossed roller rail sets (or crossed roller bearings) are compact, precision rail sets that can support and guide high loads with high accuracy, excellent repeatability, and low friction. A complete range of profiles are offered with roller diameters ranging from 1.5mm up to 6 millimeters, providing load carrying capacities to 2800 lbs. For vertical applications or applications involving high acceleration or deceleration forces you may want to consider our Anti-Creep crossed roller rail sets.
-
Millmate -
ABB Ltd.
ABB’s Millmate roll force system is the perfect choice for measuring roll force in both hot rolling and cold rolling mills, thereby achieving correct roll gap settings and force distribution.The system is proven to be exceptionally robust and resilient to high forces as well as aggressive mill agents. The load cells are calibration free, can withstand overloads up to 7 times the nominal force, and have an impressive life length. The load cells come in different sizes from 0.1MN up to 60MN.
-
ETS880 TITAN -
Hilevel Technology, Inc.
*Test rates up to 200MHz (100MHz All Modes) *Clocks up to 400MHz *Two strobes per cycle * High Pin Count: Up to 1,024 logic pins in ONE Chassis *Optionally supports up 4,096 DC pins, or combination of both * Direct Docking precision manipulator *Low Cost *Up to 64Meg test vector depth *Programmable loads and parallel loads *Multiple DC PMU units * Timing On-the-Fly * Mixed Signal Option
-
40-550-902 -
Pickering Interfaces Ltd.
This version of the 8x4 power matrix is for heavy current/low duty cycle power switching. Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current.
-
EE-120A-1S -
EMSYST Ltd
The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.
-
TA Series 18 Watt -
Semiconductor Circuits, Inc.
The 18-Watt TA series operates over an ultra wide input range of 9-36 Vdc or 20-72 Vdc. Efficiencies of 77% are typical over varying load conditions of 25% to 100%.
-
WonATech Co.,Ltd
Single channel impedance monitorA flexible frequency generator/analyzerSupporting external load/potentiostat - TDI Dynaload RBL488 series & XBL series - WonATech WEL Load - Other 3rd parties potentiostat/galvanostat
-
Elmeasure India Pvt. Ltd
Easy navigationEvent recording with time stamp (all basic & power parameters)Unbalance load and voltage with calculated neutral currentDynamic communicationOptional digital output for all basic and power parameters
-
MS-Series -
Pacific Power Source, Inc.
The MS-Series Power Sources are high performance, high efficiency, AC to AC converters. Rugged powerful output provides up to 350 amps of pulse current for driving non-linear loads.
-
Ducati energia S. p. A.
The voltage regulators made by Ducati Energia are combined with permanent magnets alternators in order to manage both the battery charging and the direct supply of AC loads (lights, cooling fan, etc).