Showing results: 4801 - 4815 of 7546 items found.
-
40-780B-552-E -
Pickering Interfaces Ltd.
The 40-780B-552-E (PXI) and 42-780B-552-E (PXIe) are dual SPDT 50GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67GHz in 50Ω or 2.5GHz in 75Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50Ω and 1.6/5.6 in 75Ω versions.
-
42-788-021 -
Pickering Interfaces Ltd.
The 40-788-021 (PXI) and 42-788-021 (PXIe) are single failsafe SP8T 18 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T configurations with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
40-781A-521-E -
Pickering Interfaces Ltd.
The 40-781A-521-E (PXI) and 42-781A-521-E (PXIe) are single failsafe SPDT 40 GHz microwave relay modules with external terminations and remotely mounted relays. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
40-788-041 -
Pickering Interfaces Ltd.
The 40-788-041 (PXI) and 42-788-041 (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
42-788-041 -
Pickering Interfaces Ltd.
The 40-788-041 (PXI) and 42-788-041 (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
42-781A-322-E -
Pickering Interfaces Ltd.
The 40-781A-322-E (PXI) and 42-781A-322-E (PXIe) are dual failsafe SPDT 26.5 GHz microwave relay modules with external terminations and remotely mounted relays. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
40-781A-322-E -
Pickering Interfaces Ltd.
The 40-781A-322-E (PXI) and 42-781A-322-E (PXIe) are dual failsafe SPDT 26.5 GHz microwave relay modules with external terminations and remotely mounted relays. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
42-781A-521-E -
Pickering Interfaces Ltd.
The 40-781A-521-E (PXI) and 42-781A-521-E (PXIe) are single failsafe SPDT 40 GHz microwave relay modules with external terminations and remotely mounted relays. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
40-788-221 -
Pickering Interfaces Ltd.
The 40-788-221 (PXI) and 42-788-221 (PXIe) are single failsafe SP12T 18 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
42-788-131 -
Pickering Interfaces Ltd.
The 40-788-131 (PXI) and 42-788-131 (PXIe) are single failsafe SP10T 22 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
40-781A-422-E -
Pickering Interfaces Ltd.
The 40-781A-422-E (PXI) and 42-781A-422-E (PXIe) are dual failsafe SPDT 40 GHz microwave relay modules with internal terminations and remotely mounted relays. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
42-788-121 -
Pickering Interfaces Ltd.
The 40-788-121 (PXI) and 42-788-121 (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
40-788-121 -
Pickering Interfaces Ltd.
The 40-788-121 (PXI) and 42-788-121 (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
42-788-221 -
Pickering Interfaces Ltd.
The 40-788-221 (PXI) and 42-788-221 (PXIe) are single failsafe SP12T 18 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
40-788-131 -
Pickering Interfaces Ltd.
The 40-788-131 (PXI) and 42-788-131 (PXIe) are single failsafe SP10T 22 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.